• Title/Summary/Keyword: Electric Coupling

Search Result 444, Processing Time 0.026 seconds

An Approximate Closed Form Representation of the Microstrip Dyadic Surface Green's Function (Mictrostrip Dyadic 표면 Green 함수의 근사표현식)

  • 최익권
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.4
    • /
    • pp.549-560
    • /
    • 1993
  • A simple closed form approximation is developed by a new approach presented in this paper for the microstrip surface dyadic Green's function which arises in the problem of an electric current point source on an infinite planar grounded dielectric substrate. This closed form approximation includes the effects of the space wave, the surface wave and their coupling within the transition region near the source, and remains accurate as near as $0.1{\pi}_1$ from the source point for a substrate thickness as large as $0.04{\pi}_1$, where, ${\pi}_1$, is the free space wavelength, This result can significantly facilitate the rigorous moment method analysis of microstrip antenna arrays on relatively this substrates of practical interest. Numerical results illustrating the accuracy of the closed form approximation are presented and CPU times associated with some mutual impedance calculations are also included.

  • PDF

A Study on the Ferroelectic and Electrooptical Properties of the Transparent Ba(LaS11/2TNbS11/2T)OS13T-PbZrOS13T-PbTiOS13T Ceramics (투광성 Ba(La1/2Nb1/2)O3-PbZrO3-PbTiO3세라믹의 강유전 및 전기광학특성에 관한 연구)

  • 김준수;류기원;박영희;박창엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.858-868
    • /
    • 1992
  • 0.085Ba(LaS11/2TNbS11/2T)OS13T-0.915Pb(ZrS1yTTiS11-yT)OS13T (0.45$\leq$y$\leq$0.65) transparent electrooptic ceramics were fabricated by two-stage sintering method. The structural, ferroelectric and electrooptic properties were investigated varying composition and second sintering time. Also the possibility of application to electrooptic device was studied. If we increase the PbZrOS13T contents, dielectric constants were increased and Curie temperature was decreased. In the composition of 0.55[mol] PbZrOS13T, electromechanical coupling factor and piezoelectric charge constant were the highest values of 43[%] and 173x10S0-12T[C/N], respectively. Mechanical quality factors were decreased with the increasing PbZrOS13T contents. Light transmittance was increased with wavelength when measured from 300[nm] to 900[nm], and with PbZrOS13T contents in the range of 0.50[mol]-0.65[mol], and had the highest value of 67[%] in the composition of 0.65[mol] PbZrOS13T. From the results of ferroelectric hysteresis loop and transmitted light intensity with electric field, the specimens with compositions of 0.65,0.60,0.55[mol] PbZrOS13T were applicable to electrooptic memory device and those with compositions of 0.50,0.45[mol] PbZrOS13T were applicable to linear electrooptic device.

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

A Study on Optical Current Sensor and Voltage Sensor for automation of power distribution (배전자동화 개폐기 내장형 광 전류 및 광 전압 센서에 관한 연구)

  • 양승국;오상기;박해수;김인수;김요희;홍창희
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.89-98
    • /
    • 2002
  • Optical current sensor and optical voltage sensor modules were designed and fabricated to improve measurement error and insulation in automatic power distributor By using Faraday effect, optical current sensor with an $\alpha$-iron core was designed and fabricated to minimize current induction of the other phase and was optimized to maintain linearity. Optical voltage sensor was fabricated owing to the pockets effect and adopted spatial electric field type because of small room in an automatic power distributor. To connect a distributor with an external terminal for signal processing, optical multi connector was designed, fabricated and tested for coupling loss and gas leakage. The linearity of optical current sensor for applied current maintains variation of smaller than 2.5% for applied current range from 20A to 700A. The linearity of optical voltage sensor was smaller than 1% for appling voltage from 6.6kV to 19.8kV. Since the measured characteristics are good, these devices can be considered as being applicable in practice.

The Piezoelectic and electromechanical Characteristics of PZ-PT-PMWS (PZ-PT-PMWS의 압전 및 전기기계적 특성)

  • 홍종국;이종섭;채홍인;윤만순;정수현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.403-406
    • /
    • 2000
  • The piezoelectric properties and the doping effect of N $b_2$ $O_{5}$ and Mn $O_2$for 0.95PbZ $r_{x}$ $Ti_{x}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$ compositions have been investigated. In the composition of 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$the Values Of $k_{p}$ find and $\varepsilon$$_{33}$ $^{T}$ are maximized, but $Q_{m}$ Was minimized ( $k_{p}$ =0.51, $Q_{m}$ =1750). The grain size was suppressed and the uniformity of grain was improved with doping concentration of N $b_2$ $O_{5}$ for 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.005Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$sample. The values of $k_{p}$ increased and the values of $Q_{m}$ slightly decreased when 0.5 wt% of N $b_2$ $O_{5}$ is doped. And the values of $k_{p}$ was the same formation of the N $b_2$ $O_{5}$ dopant when 0.5 wt% of M $n_2$ $O_{5}$ is doped. But the values of $Q_{m}$ was deeply decreased when 0.5 wt% of Mn $O_2$is doped. As a experiment results under high electric field driving, this piezoelectric ceramics are very stable. Conclusively, piezoelectric ceramic compsiton investigated at this paper is suitable for application to high power piezoelectric devices.. devices..ices.. devices..

  • PDF

Simultaneously Enhanced Magnetic and Ferroelectric Properties of $Bi_{0.9}Dy_{0.1}Fe_{0.97}Co_{0.03}O_3 $ compound

  • Yu, Yeong-Jun;Hwang, Ji-Seop;Park, Jeong-Su;Lee, Ju-Yeol;Gang, Ji-Hun;Lee, Gwang-Hun;Lee, Bo-Hwa;Kim, Gi-Won;Lee, Yeong-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.147-147
    • /
    • 2013
  • Multiferroic material $BiFeO_3$ (BFO) is a typical multiferroic material with a room-temperature magnetoelectric coupling in view of high magnetic- and ferroelectric-ordering temperatures (Neel temperature $T_N$ ~ 647 K and Curie temperature TC ~1,103 K). Rare-earth ion substitution at the Bi sites is very interesting, which induces suppressed volatility of the Bi ion and improved ferroelectric properties. At the same time, the Fe-site substitution with magnetic ions is also attracting, since the enhanced ferromagnetism was reported. In this study, BFO, $Bi_{0.9}Dy_{0.1}FeO_3$ (BDFO), $BiFe_{0.97}Co_{0.03}O_3$ (BFCO) and $Bi_{0.9}Dy_{0.1}Fe_{0.97}Co_{0.03}O_3 $ (BDFCO) compounds were prepared by conventional solid-state reaction and wet-mixing method. High-purity $Bi_2O_3$, $Dy_2O_3$, $Fe_2O_3$ and $Co_3O_4$ powders with the stoichiometric proportions were mixed, and calcined at $500^{\circ}C$ for 24 h. The samples were immediately put into an oven, which was heated up to 800oC and sintered in air for 1 h. The crystalline structure of samples was investigated at room temperature by using a Rigaku Miniflex powder diffractometer. The field-dependent magnetization measurements were performed with a vibrating-sample magnetometer. The electric polarization was measured at room temperature by using a standard ferroelectric tester (RT66B, Radiant Technologies). Dy and Co co-doping at the Bi and the Fe sites induce the enhancement of both magnetic and ferroelectric properties of $BiFeO_3$.

  • PDF

Thermal buckling analysis of magneto-electro-elastic porous FG beam in thermal environment

  • Ebrahimi, Farzad;Jafari, Ali;Selvamani, Rajendran
    • Advances in nano research
    • /
    • v.8 no.1
    • /
    • pp.83-94
    • /
    • 2020
  • An analytical formulation and solution process for the buckling analysis of porous magneto-electro-elastic functionally graded (MEE-FG) beam via different thermal loadings and various boundary conditions is suggested in this paper. Magneto electro mechanical coupling properties of FGM beam are taken to vary via the thickness direction of beam. The rule of power-law is changed to consider inclusion of porosity according to even and uneven distribution. Pores possibly occur inside FGMs due the result of technical problems that lead to creation of micro-voids in these materials. Change in pores along the thickness direction stimulates the mechanical and physical properties. Four-variable tangential-exponential refined theory is employed to derive the governing equations and boundary conditions of porous FGM beam under magneto-electrical field via Hamilton's principle. An analytical model procedure is adopted to achieve the non-dimensional buckling load of porous FG beam exposed to magneto-electrical field with various boundary conditions. In order to evaluate the influence of thermal loadings, material graduation exponent, coefficient of porosity, porosity distribution, magnetic potential, electric voltage and boundary conditions on the critical buckling temperature of the beam made of magneto electro elastic FG materials with porosities a parametric study is presented. It is concluded that these parameters play remarkable roles on the buckling behavior of porous MEE-FG beam. The results for simpler states are proved for exactness with known data in the literature. The proposed numerical results can serve as benchmarks for future analyses of MEE-FG beam with porosity phases.

Estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Isalnd (제주지역 계통운전조건을 고려한 풍력발전단지용 최소 BESS용량 산정)

  • Jin, Kyung-Min;Kim, Seong Hyun;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.39-45
    • /
    • 2013
  • This paper presents the estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Island. To analyze the characteristics of wind farm outputs with a BESS, the real data of wind farms, Sung-San, Sam-dal and Hang-Won wind farm, located in the eastern part of Jeju island is considered. The wind farms are connected to Sung-san substation to transfer the electric power to Jeju power grid. Consequently, at PCC (Point of Common Coupling), it can see a huge wind farm connected to the substation and thus it can be expected that the smoothing effect is affected by not only the different wind speeds for each area but also the different mechanical inertia of wind turbines. In this paper, two kinds of simulation have been carried out. One is to analyze the real data of wind farm outputs during a winter season, and the other is to connect a virtual BESS to eliminate the unintended generating power changes by the uncontrolled wind farm outputs as shown in the former data. In the conclusion, two kinds of simulation results show that BESS installed in the substation is more efficient than each wind farms with BESS, respectively.

Finite Element Analysis of RF Coupler in Normal-Low Temperature (상온-저온 RF 커플러 유한요소해석)

  • Kim, Hansol;Lee, Hak Yong;Park, Chan;Lee, Jaeyeol;Lim, Dong Yeal;Yoo, Jeonghoon;Hyun, Myung Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1101-1107
    • /
    • 2014
  • A heavy ion accelerator is a device that accelerates heavy ions in the radio frequency (RF) range. The electric field that flows into the RF cavity continuously accelerates heavy ions in accordance with the phase of the input electromagnetic wave. For the purpose, it is necessary to design a coupler shape that can stably transfer the RF wave into the cavity. The RF coupler in a heavy ion accelerator has a large temperature difference between the input port and output port, which radiates the RF waves. It is necessary to consider the heat deflection on the RF coupler that occurs as a result of the rapid temperature gradient from an ultra-low temperature about 0 K to a room temperature about 300 K. The purpose of this study was to improve the system performance through an analysis of the intensity of the output electric field and temperature distribution considering various shapes of the RF coupler, along with an analysis of the durability considering the heat deflection and heat loss.

The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator (전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구)

  • Lee, Kang-Wuk;Park, Jeong-Ho;Jang, Seong-Ho;Lim, Woo-Taik;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.