• Title/Summary/Keyword: Electric Control

Search Result 4,651, Processing Time 0.035 seconds

Flow Rate Changes in the Heterogeneous Rectangular Microchannels with Different Hydrophilicity for the PDMS Bottom Surface (PDMS 표면특성에 따른 비균일계 마이크로채널의 유속 변화)

  • Noh, Soon-Young;Lee, Hyo-Song;Kim, Ki-Ho;Choi, Jae-Ho;Yu, Jae-Keun;Yoon, Soo-Kyung;Rhee, Young-Woo
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • This study investigated the flow rate changes of the heterogeneous rectangular microchannels which have different hydrophilic property on the bottom surface. The heterogeneous rectangular microchannel has three native PDMS (poly-dimethyl siloxane) surfaces which were patterned by the soft lithography. PDMS bottom surface was treated by the argon plasma and coated by the allyl alcohol (99%). The channel length was 10, 20 and 30 mm and the channel width was 100, 200 and $300\;{\mu}m$, respectively. Several external voltages were applied to make the fluid flow by the electroosmosis in the microchannel. For the same electric field strength and hydrophilicity of the bottom surface, the flow rate is almost same. This result is matched to the theoretical expectation and confirms that the experimental system is reliable. With increasing the channel width, the flow rate increased for the same hydrophilicity of the bottom surface. The flow rate of the microchannel of higher hydrophilicity was larger than that of the microchannel of lower hydrophilicity. This result implies that the hydrophilicity change of the bottom surface could be applied to control the flow rate in the microchannel.

  • PDF

Functional Analysis of Electrode and Small Stack Operation in Solid Oxide Fuel Cell (고체산화물 연료전지의 전극과 스택운영의 기능적 분석)

  • Bae, Joong-Myeon;Kim, Ki-Hyun;Ji, Hyun-Jin;Kim, Jung-Hyun;Kang, In-Yong;Lim, Sung-Kwang;Yoo, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.812-822
    • /
    • 2006
  • This study amis to investigate the functional analysis of anode and cathode materials in Anode supported Solid Oxide Fuel Cell. The concentration polarization of single cell was investigated with CFD (Computational Fluid Dynamics) method for the case of the different morphology by using four types of unit cell and discussed to reduce the concentration polarization. The concentration polarization at anode side effected the voltage loss in Anode supported Solid Oxide Fuel Cell and increased contact areas between fuel gas and anode side could reduce the concentration polarization. For intermediate temperature operation, Anode-supported single cells with thin electrolyte layer of YSZ (Yttria-Stabilized Zirconia) were fabricated and short stacks were built and evaluated. We also developed diesel and methane autothermal reforming (ATR) reactors in order to provide fuels to SOFC stacks. Influences of the $H_2O/C$ (steam to carbon ratio), $O_2/C$ (oxygen to carbon ratio) and GHSV (Gas Hourly Space Velocity) on performances of stacks have been investigated. Performance of the stack operated with a diesel reformer was lower than with using hydrogen as a fuel due to lower Nernst voltage and carbon formation at anode side. The stack operated with a natural gas reformer showed similar performances as with using hydrogen. Effects of various reformer parameters such as $H_2O/C$ and $O_2/C$ were carefully investigated. It is found that $O_2/C$ is a sensitive parameter to control stack performance.

A Study on the Phobia Treatment Using 3D Virtual Reality System (3D 가상환경시스템 이용한 공포증 치료에 대한 연구)

  • Paek Seung-Eun
    • The Journal of Information Technology
    • /
    • v.5 no.4
    • /
    • pp.45-55
    • /
    • 2002
  • Virtual Reality(VR) is a new technology which makes humans communicate with computer. It allows the user to see, hear, feel and interact in a three-dimensional virtual world created graphically. In this paper, we introduced VR into psychotherapy area and developed VR system for the exposure therapy of acrophobia. Acrophobia is an abnormal fear of heights. Medications or cognitive-behavior methods have been mainly used as a treatment. Lately the virtual reality technology has been applied to that kind of anxiety disorders. A virtual environment provides patient with stimuli which arouses phobia, and exposing to that environment makes him having ability to over come the fear. In this study, the elevator stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a feel of phobia and without phobia, heart rate was measured during experiment. And also measured a person's HR after the virtual reality training. In this study, we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

Encoder Type Semantic Segmentation Algorithm Using Multi-scale Learning Type for Road Surface Damage Recognition (도로 노면 파손 인식을 위한 Multi-scale 학습 방식의 암호화 형식 의미론적 분할 알고리즘)

  • Shim, Seungbo;Song, Young Eun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.89-103
    • /
    • 2020
  • As we face an aging society, the demand for personal mobility for disabled and aged people is increasing. In fact, as of 2017, the number of electric wheelchair in the country continues to increase to 90,000. However, people with disabilities and seniors are more likely to have accidents while driving, because their judgment and coordination are inferior to normal people. One of the causes of the accident is the interference of personal vehicle steering control due to unbalanced road surface conditions. In this paper, we introduce a encoder type semantic segmentation algorithm that can recognize road conditions at high speed to prevent such accidents. To this end, more than 1,500 training data and 150 test data including road surface damage were newly secured. With the data, we proposed a deep neural network composed of encoder stages, unlike the Auto-encoding type consisting of encoder and decoder stages. Compared to the conventional method, this deep neural network has a 4.45% increase in mean accuracy, a 59.2% decrease in parameters, and an 11.9% increase in computation speed. It is expected that safe personal transportation will be come soon by utilizing such high speed algorithm.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

The Development of X-ray Unit of Remote Emergency medical System (원격응급시스템에 적합한 X-ray 장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yang, Hae-Sool;Han, Man-Seok;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.49-54
    • /
    • 2006
  • The X-ray unit developed by this study is to diagnose emergency cases which is too far from a hospital and to classify the patients. We have to use the X-ray in a ambulance or the scene of an accident where we cannot use the AC220 outlet because of the distance from a hospital as well. The X-ray unit developed has a characteristics as follows. First of all, as the unit has a condenser in itself where there is no electric supply, we can use the X-ray inspector in a mountain area or a island. Second, we can detect by digital detector the information taken by X-ray from DC 12[V] electricity and store as a form of file. A control circuit can secure the reliability of the X-ray unit by using the Pic16F84A X-ray and provide various functions. The X-ray unit which suits remote emergency system can be efficiently used for the emergent cases who is too far from a doctor and a hospital or in the situation where it is difficult to diagnose, transcribe and treat simultaneously.

Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields (반도체 제조 근로자의 극저주파 자기장 노출 평가)

  • Chung, Eun Kyo;Kim, Kab Bae;Chung, Kwang Jae;Lee, In Seop;You, Ki Ho;Park, Jung-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.