Ratcheting behavior of 90° elbow piping under seismic loading

  • Chen, Xiaohui;Huang, Kaicheng;Ye, Sheng;Fan, Yuchen;Li, Zifeng
    • Earthquakes and Structures
    • /
    • v.17 no.5
    • /
    • pp.489-499
    • /
    • 2019
  • Elastic-plastic behavior of nuclear power plant elbow piping under seismic loads has been conducted in this study. Finite element analyses are performed using classical Bilinear kinematic hardening model (BKIN) and Multilinear kinematic hardening model (MKIN) as well as a nonlinear kinematic hardening model (Chaboche model). The influence of internal pressure and seismic loading on ratcheting strain of elbow pipe is studied by means of the three models. The results found that the predicted results of Chaboche model is maximum, closely followed by the predicted results of MKIN model, and the minimum is the predicted results of BKIN model. Moreover, comparisons of analysis results for each plasticity model against predicted results for a equivalent cyclic loading elbow component and for a simplified piping system seismic test are presented in the paper.

Effect of Diameter and Thickness on the Failure Location and Orientation of 90° Elbows Under In-plane Mode Cyclic Bending (In-plane 모드 반복굽힘 조건에서 90° 엘보우의 손상 위치와 방향에 미치는 직경과 두께 영향)

  • Jin Ney Hong;Jin Weon Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.77-86
    • /
    • 2022
  • This study investigates the effect of the diameter and thickness on crack initiation location and orientation of 90° elbows under in-plane mode displacement-controlled cyclic bending loads. Finite element (FE) analysis of cyclic failure test is conducted for elbow specimens under in-plane mode displacement-controlled cyclic bending to identify the parameters affecting crack location and orientation. Furthermore, parametric FE analysis of the pipe elbows with various pipe nominal sizes and Schedules is performed, and the crack location and orientation from the results of FE analysis are determined. It is found that the crack location and orientation in the pipe elbows are determined mianly by the radius to thickness ratio of pipe elbows (Rm/t). It is also found that the presence of internal pressure slightly increases the value of Rm/t at which the failure mode changes.

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry in Small Size Pipe (2) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(2))

  • 이동원;윤찬일;주문창
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2002
  • Pressure drop were experimentally investigated for ice slurry flowing in the acrylic pipes with inner diameter of 24 mm. Ice slurry was made from 6.5% ethylene glycol-water solution, and the pipes is consisted of horizontal, vertical (upward and downward) and $90^{\circ}$ elbow pipe. The ice Packing factor (IPF) and the flow rate of the experiments were varied from 0 to 30% and from 5 to 70kg/min respectively The measured pressure drop in various pipe positions were compared with those for the solution flow (IPF=0). The pressure drop was larder than that for solution flows as the IPF increased when the flow rate was low or very high. Sharp increases in pressure drop were observed for the cases when IPF is more than 70% in horizontal and vertical pipes, whereas the pressure drop increased with the IPF simultaneously in an elbow pipe.

Effects of the Changes in Flow Pattern on Convective Heat Transfer in the Vicinity of Pipe Elbow (유동형태 변화가 배관 곡관부 대류열전달에 미치는 영향)

  • Song, Seung-Hyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • In this study, by varying flow patterns, which is one of the hydraulic factors of FAC, a strategy to reduce pipe wall thinning by mass transfer has been investigated. A similarity between heat transfer and mass transfer was verified via theoretical analysis, and local convective heat transfer coefficients were analyzed using a commercial numerical analysis program. When ribs were installed inside and outside of the internal surface in the straight section of the pipe, the maximum local heat transfer coefficient was shown to decrease substantially by up to 24.9% compared to the basic flow depending on the position and shape of ribs. If a guide vein was inserted in the pipe elbow, the maximum local heat transfer coefficient decreased by up to 26.7% compared to the basic flow depending on the internal surface area of the pipe by the guide vein.

Proposal of a Simulated Test Method for the Evaluation of Deformation and Failure Characteristics of Pipe Elbows under Cyclic Loads (반복하중 하의 엘보우 변형 및 손상 특성 평가를 위한 모사시험 방법 제안)

  • Kim, Jin Weon;Lee, Dae Young;Park, Heung Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • This study proposed a simulated test method using ring specimen to evaluate the deformation and failure characteristics of pipe elbows under a large amplitude cyclic load. The validity of the test method was demonstrated by finite element (FE) analysis of pipe elbow and ring specimen under cyclic loads. The results showed that the proposed test method adequately simulates the distribution of circumferential strain at crown of pipe elbows where cracks occur under cyclic loads and presents the cyclic hardening behavior of pipe elbows. The parametric FE analysis showed that consistent simulated test results could be obtained when the test section of the ring specimen is longer than 1/2 of the inner diameter of the ring specimen and the radius of the inner loading jig is less than 1/4 of the inner diameter of the specimen.

Flow-accelerated corrosion assessment for SA106 and SA335 pipes with elbows and welds

  • Kim, Dong-Jin;Kim, Sung-Woo;Lee, Jong Yeon;Kim, Kyung Mo;Oh, Se Beom;Lee, Gyeong Geun;Kim, Jongbeom;Hwang, Seong-Sik;Choi, Min Jae;Lim, Yun Soo;Cho, Sung Hwan;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3003-3011
    • /
    • 2021
  • A FAC (flow-accelerated corrosion) test was performed for a straight pipe composed of the SA335 Gr P22 and SA106 Gr B (SA106-SA335-SA106) types of steel with welds as a function of the flow rate in the range of 7-12 m/s at 150 ℃ and with DO < 5 ppb at pH levels ranging from 7 to 9.5 up to a cumulative test time of 7200 h using the FAC demonstration test facility. Afterward, the experimental pipe was examined destructively to investigate opposite effects as well as entrance effects. In addition, the FAC rate obtained using a pipe specimen with a 50 mm inner diameter was compared with the rate obtained from a rotating cylindrical electrode. The effects of the complicated fluid flows at the elbow and orifice of the pipeline were also evaluated using another test section designed to examine the independent effects of the orifice and the elbow depending on the distance and the combined effects on orifice and elbow. The tests were performed under the following conditions: 130-150 ℃, DO < 5 ppb, pH 7 and a flow rate of 3 m/s. The FAC rate was determined using the thickness change obtained from commercial room-temperature ultrasonic testing (UT).

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

  • Kim, Do-Youn;Cho, Youn-Ho;Lee, Joon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.546-551
    • /
    • 2010
  • The objective of this research is to estimate the crack location and size of a carbon steel pipe by using a laser ultrasound guided wave for the wall thinning evaluation of an elbow. The wall thinning of the carbon steel pipe is one of the most serious problems in nuclear power plants, especially the wall thinning of the carbon steel elbow caused by Flow-Accelerated Corrosion (FAC). Therefore, a non-destructive inspection method of elbow is essential for the nuclear power plants to operate safely. The specimens used in this study were carbon steel elbows, which represented the main elements of real nuclear power plants. The shape of the wall thinning was an oval with a width of 120mm, a length of 80mm, and a depth of 5mm. The L(0,1) and L(0,2) modes variation of the ultrasound guided wave signal is obtained from the response of the laser generation/air-coupled detection ultrasonic hybrid system represent the characteristics of the defect. The trends of these characteristics and signal processing were used to estimate the size and location of wall thinning.

Analysis of Pipe Failure Period Using Pipe Elbow Erosion Model by Computational Fluid Dynamics (CFD) (전산유체역학 배관 곡면 침식 모사를 통한 배관 실패 주기 분석)

  • Nam, Chongyong;Lee, Yongkyu;Park, Gunhee;Lee, Gunhak;Lee, Won Bo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.133-138
    • /
    • 2018
  • Safety management has become even more important because of the safety and environmental issues that have arisen since the 2000s. However, the safety study requires many empirical data, so there are many limitations. In the case of pipe safety, simulation programs exist, but it is difficult to get data about the pipe internal erosion of the pipe. In this study, the erosion rate of the pipe elbow was simulated using computational fluid dynamics (CFD). Also, the failure period of the pipe was calculated by the limit state function using erosion rate. In the case of CFD pipe, a sample which is actually operated in Yeosu industrial complex was used, and the geometry and mesh formation were rationalized in terms of typical fluid dynamics simulations. Using the Discrete Phase Model (DPM) and the corrosion model, the erosion rate ($3.09227mm{\cdot}yr^{-1}$) was obtained from CFD simulations. As a result of applying the erosion rate to the limit state function, we obtained the pipe failure period value, 14.2 years to trigger a leak and 28.2 years to trigger a burst. Through these processes, we concluded that pipe erosion is one of the major failure modes. In addition to the results, this study has significance for suggesting the methodology of the pipe safety study.

A Study on Automatic Modeling of Pipelines Connection Using Point Cloud (포인트 클라우드를 이용한 파이프라인 연결 자동 모델링에 관한 연구)

  • Lee, Jae Won;Patil, Ashok Kumar;Holi, Pavitra;Chai, Young Ho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.3
    • /
    • pp.341-352
    • /
    • 2016
  • Manual 3D pipeline modeling from LiDAR scanned point cloud data is laborious and time-consuming process. This paper presents a method to extract the pipe, elbow and branch information which is essential to the automatic modeling of the pipeline connection. The pipe geometry is estimated from the point cloud data through the Hough transform and the elbow position is calculated by the medial axis intersection for assembling the nearest pair of pipes. The branch is also created for a pair of pipe segments by estimating the virtual points on one pipe segment and checking for any feasible intersection with the other pipe's endpoint within the pre-defined range of distance. As a result of the automatic modeling, a complete 3D pipeline model is generated by connecting the extracted information of pipes, elbows and branches.

The Structure Integrity Assessment of the Wall Thinned Elbow Considering In/Out-Plane Bending (열림·닫힘 방향 하중이 고려된 두께 감소된 엘보우의 건전성평가)

  • Jang, Ungburm;Shin, Kyuin;Lee, Sungho;Kuan, Changhee
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Local wall thinning elbow due to the water flow is one of the main degradation phenomenon in carbon steel pipe of plant system. The API579 code of FFS (fitness for service) used in the chemical plant gives a guideline to protect local wall thin problem in a straight pipe, but it does not include an elbow. In this study, the locally wall thinned elbow, which is considered an extrados or intrados wall thinned elbow, was carried out considering in-plane or out-plane bending using FEM (finite element method) analysis, and some of results were also compared with the experimental data. The results could give the structure integrity assessment to protect the local wall thinned elbow.