• Title/Summary/Keyword: Elbow method

Search Result 382, Processing Time 0.023 seconds

Arthroscopic-assisted Reduction and Percutaneous Screw Fixation for Glenoid Fracture with Scapular Extension

  • Kim, Se Jin;Lee, Sung Hyun;Jung, Dae Woong;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.147-152
    • /
    • 2017
  • Background: To evaluate the clinical and functional outcomes of arthroscopic-assisted reduction and percutaneous screw fixation for glenoid fractures with scapular extension, and investigate the radiologic and clinical benefits from the results. Methods: We evaluated patients treated with arthroscopic-assisted reduction and percutaneous screw fixation for glenoid fractures with scapular extension from November 2008 to September 2015. Fractures with displacement exceeding one-fourth of the anterior-articular surface or more than one-third of the posterior-articular surface in radiographic images were treated by surgery. Clinical assessment was conducted based on range of motion, Rowe score, and Constant score of injured arm and uninjured arm at last follow-up. Results: Fifteen patients with Ideberg classification grade III, IV, and V glenoid fracture who underwent arthroscopic-assisted reduction using percutaneous screw fixation were retrospectively enrolled. There were no differences in clinical outcomes at final follow-up compared to uninjured arm. Bone union was seen in all cases within five months, and the average time to bone union was 15.2 weeks. Ankylosis in one case was observed as a postoperative complication, but the symptoms improved in response to physical therapy for six months. There was no failure of fixation and neurovascular complication. Conclusions: We identified acceptable results upon radiological and clinical assessment for the arthroscopic-assisted reduction and percutaneous fixation. For this reason, we believe the method is favorable for the treatment of Ideberg type III, IV, and V glenoid fractures. Restoration of the articular surface is considered to be more important than reduction of fractures reduction of the scapula body.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Normal Range of Humeral Head Positioning on the Glenoid on Magnetic Resonance Imaging: Validation through Comparison of Computed Tomography and Magnetic Resonance Imaging

  • Kim, Jung-Han;Min, Young-Kyoung
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.186-191
    • /
    • 2018
  • Background: To determine the normal range of humeral head positioning on magnetic resonance imaging (MRI). Methods: We selected normal subjects (64 patients; group A) to study the normal range of humeral head positioning on the glenoid by MRI measurements. To compare the MRI measurement method with the computed tomography (CT), we selected group B (70 patients) who underwent both MRI and CT. We measured the humeral-scapular alignment (HSA) and the humeral-glenoid alignment (HGA). Results: The HSA in the control group was $1.47{\pm}1.05mm$, and the HGA with and without reconstruction were $1.15{\pm}0.65mm$ and $1.03{\pm}0.59mm$, respectively, on MRI. In the test group, HSA was $2.67{\pm}1.47mm$ and HGA with and without reconstruction was $1.58{\pm}1.16mm$ and $1.49{\pm}1.08mm$, on MRI. On CT, the HSA was $1.72{\pm}1.01mm$, and HGA with and without reconstruction were $1.54{\pm}0.96mm$ and $1.59{\pm}0.93mm$, respectively. HSA was significantly different according to image modality (p=0.0006), but HGA was not significantly different regardless of reconstruction (p=0.8836 and 0.9234). Conclusions: Although additional CT scans can be taken to measure decentering in patients with rotator cuff tears, reliable measurements can be obtained with MRI alone. When using MRI, it is better to use HGA, which is a more reliable measurement value based on the comparison with CT measurement (study design: Study of Diagnostic Test; Level of evidence II).

The Effect of Upper and Lower Extremity Coordination Training with Elastic Band on Balance and Functional Ability for Chronic Stroke Patients (탄력밴드를 이용한 팔과 다리 협응 훈련이 만성 뇌졸중 환자의 균형 및 기능에 미치는 영향)

  • Kim, Hee-Dong;Choi, Jae-Won;Cho, Yong-Ho
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.119-127
    • /
    • 2019
  • Purpose: The purpose of this study is to show the effect of elastic band on balance and functional ability in chronic stroke patients living in community. Methods: The subjects who participated in the study were 9 patients with chronic stroke. One of them gave up during the study, finally 8 patients performed. The intervention was conducted once a week for 10 weeks. In this study functional reach test (FRT), timed up and go test (TUG), Tinetti performance oriented mobility assessment (Tinetti-POMA) were measured for balance. The coordination training of arms and legs using the elastic band was performed in three positions as supine, side lying, sitting. One arm performed flexion-adduction- external rotation with elbow flexion pattern and the opposite side(diagonal) leg was performed flexion-adduction-external rotation with knee flexion pattern, the other arm's pattern was extension-abduction-internal rotation with elbow extension and the opposite side (diagonal) leg was in extension-abduction-internal rotation with knee extension pattern. The training was performed in each position for 15 minutes in per position. The participants had a five minute break after each training. Results: The results are as follows. FRT and Tinetti-POMA showed significant increase statistically in each position. The TUG showed significant decrease statistically in each position. Conclusion: Even though the coordination training with elastic band had performed once a week, it showed positive effects on balance in chronic stroke patients. Therefore, if we can suggest the appropriate frequencies of coordination training of arms and legs using the elastic band, it can be a method to improve daily life and life quality to patients with chronic stroke.

The benefit of platelet-rich plasma injection over institution-based physical therapy program in adhesive capsulitis patients with diabetes mellitus: prospective observational cohort study

  • Barman, Apurba;Mukherjee, Somnath;Sinha, Mithilesh K;Sahoo, Jagannatha;Viswanath, Amrutha
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 2021
  • Background: The objective of this study was to compare the efficacy of platelet-rich plasma (PRP) injection with an institution-based physical therapy (PT) program for adhesive capsulitis (AC) of the shoulder in patients with diabetes mellitus (DM). Methods: A total of seventy diabetic patients with AC of the shoulder for <6 months were assigned to two groups: PRP group and PT group. In the PRP group, 35 patients were administered a single shot of PRP (4 mL) into the glenohumeral joint. In the PT group, 35 patients were given institution-based PT that included 10 30-minute sessions of planned PT over a 2-week period. After the interventions, all patients were prospectively followed for 12 weeks. Intensity of shoulder pain, function, and range of motion were assessed at baseline and then at 3, 6, and 12 weeks. Results: Thirty-three patients in the PRP group and 32 in the PT group completed the 12-week study. At 12 weeks, patients who received PRP injections showed greater improvement in shoulder pain (p<0.001) than those recruited to the PT group. In the range of motion and shoulder function activities, patients in the PRP group showed significant improvement compared with the institution-based PT group (p<0.001). No significant complications were reported from any groups. Conclusions: In a diabetic population, PRP injections significantly improved shoulder pain and function compared with an institution-based PT program for shoulder AC. Additionally, it is a safe and well-tolerated method for AC management for diabetic patients.

Mixed reality visualization in shoulder arthroplasty: is it better than traditional preoperative planning software?

  • Sejla Abdic;Nicholas J. Van Osch;Daniel G. Langohr;James A. Johnson;George S. Athwal
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.117-125
    • /
    • 2023
  • Background: Preoperative traditional software planning (TSP) is a method used to assist surgeons with implant selection and glenoid guide-pin insertion in shoulder arthroplasty. Mixed reality (MR) is a new technology that uses digital holograms of the preoperative plan and guide-pin trajectory projected into the operative field. The purpose of this study was to compare TSP to MR in a simulated surgical environment involving insertion of guide-pins into models of severely deformed glenoids. Methods: Eight surgeons inserted guide-pins into eight randomized three-dimensional-printed severely eroded glenoid models in a simulated surgical environment using either TSP or MR. In total, 128 glenoid models were used and statistically compared. The outcomes compared between techniques included procedural time, difference in guide-pin start point, difference in version and inclination, and surgeon confidence via a confidence rating scale. Results: When comparing traditional preoperative software planning to MR visualization as techniques to assist surgeons in glenoid guide pin insertion, there were no statistically significant differences in terms of mean procedure time (P=0.634), glenoid start-point (TSP=2.2±0.2 mm, MR=2.1±0.1 mm; P=0.760), guide-pin orientation (P=0.586), or confidence rating score (P=0.850). Conclusions: The results demonstrate that there were no significant differences between traditional preoperative software planning and MR visualization for guide-pin placement into models of eroded glenoids. A perceived benefit of MR is the real-time intraoperative visibility of the surgical plan and the patient's anatomy; however, this did not translate into decreased procedural time or improved guide-pin position.

Development and Efficiency Evaluation of Auxiliary Shielding using Elbow Support (팔꿈치 지지대를 사용한 보조 차폐 기구의 개발 및 효용성 평가)

  • Hyun-Woo Im;Jae-Suk Kim;Dong-Gu Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.11-20
    • /
    • 2024
  • As the importance of intervention has recently increased, interest in the health of medical staff performing the procedure is increasing. Existing radiation shielding devices have limited the operator's movement and have not been properly used due to the risk of infection, and adequate radiation shielding of the operator's gonads and furthermore, the entire area of the procedure room has not been achieved. An auxiliary shielding device was manufactured by attaching a Bismuth to the elbow support used in the procedure, and the radiation shielding effect was measured. As a result of the measurement, the average spatial dose rate decreased by about 64.8%, and the independent sample t-test analysis showed statistically significant below the significance probability (p<0.05). The use of an auxiliary shielding device is considered to be an effective shielding method that can shield the operator's gonads and reduce the radiation spatial dose rate of the entire area of the procedure room.

Relationship of Follow-through Movements to Target Accuracy in Compound Archers (컴파운드 양궁의 팔로우 스루 동작과 사격 정확도의 상관관계)

  • Junkyung Song;Kitae Kim
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.1
    • /
    • pp.34-44
    • /
    • 2024
  • Objective: This study aimed to investigate how the movements occurring during the follow-through phase after releasing an arrow among elite compound archers, are associated with the arrow impact points on the target. Method: Nine elite archers performed consecutive compound archery shooting under conditions identical to actual competitions using their own bows and equipment. Motion capture system and force platform were utilized to record the changes in joint positions and center of pressure, respectively. Principal component analysis was employed to identify the patterns in which multidimensional joint positions and COP changes were organized with horizontal and vertical coordinates of arrow impact points. Subsequently, correlation analysis quantified the relationship between individual variables and the coordinates of arrow impacts on the target. Results: We found a common organizational pattern in which the two axes of the impact point coordinates were grouped into the first two principal components. The movements of the upper and lower limbs following release exhibited opposite patterns in the anterior-posterior axis, with significant correlations observed between the arrow impact points of the horizontal axis and the left shoulder, right elbow, left hip, and both knees. Additionally, the lateral movements induced by the reaction force upon arrow release showed significant associations with the vertical coordinates of the impact points. Particularly, the correlations between the movements of the left shoulder and elbow, as well as the bilateral hip and right knee, were consistently observed among all participants. Conclusion: These findings implied that the post-release movements could significantly influence the trajectory and impact points of the arrows in compound archery. We suggest that a consistent and controlled movement during the follow-through phase may be more beneficial for optimizing shooting accuracy and precision rather than minimizing movements.

Prediction of the Upper Limb Motion Based on a Geometrical Muscle Changes for Physical Human Machine Interaction (물리적 인간 기계 상호작용을 위한 근육의 기하학적 형상 변화를 이용한 상지부 움직임 예측)

  • Han, Hyon-Young;Kim, Jung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.927-932
    • /
    • 2010
  • Estimation methods of motion intention from bio-signal present challenges in man machine interaction(MMI) to offer user's command to machine without control of any devices. Measurements of meaningful bio-signals that contain the motion intention and motion estimation methods from bio-signal are important issues for accurate and safe interaction. This paper proposes a novel motion estimation sensor based on a geometrical muscle changes, and a motion estimation method using the sensor. For estimation of the motion, we measure the circumference change of the muscle which is proportional to muscle activation level using a flexible piezoelectric cable (pMAS, piezo muscle activation sensor), designed in band type. The pMAS measures variations of the cable band that originate from circumference changes of muscle bundles. Moreover, we estimate the elbow motion by applying the sensor to upper limb with least square method. The proposed sensor and prediction method are simple to use so that they can be used to motion prediction device and methods in rehabilitation and sports fields.

Human-like Arm Movement Planning for Humanoid Robots Using Motion Capture Database (모션캡쳐 데이터베이스를 이용한 인간형 로봇의 인간다운 팔 움직임 계획)

  • Kim, Seung-Su;Kim, Chang-Hwan;Park, Jong-Hyeon;You, Bum-Jae
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.2
    • /
    • pp.188-196
    • /
    • 2006
  • During the communication and interaction with a human using motions or gestures, a humanoid robot needs not only to look like a human but also to behave like a human to make sure the meanings of the motions or gestures. Among various human-like behaviors, arm motions of the humanoid robot are essential for the communication with people through motions. In this work, a mathematical representation for characterizing human arm motions is first proposed. The human arm motions are characterized by the elbow elevation angle which is determined using the position and orientation of human hands. That representation is mathematically obtained using an approximation tool, Response Surface Method (RSM). Then a method to generate human-like arm motions in real time using the proposed representation is presented. The proposed method was evaluated to generate human-like arm motions when the humanoid robot was asked to move its arms from a point to another point including the rotation of its hand. The example motion was performed using the KIST humanoid robot, MAHRU.

  • PDF