• 제목/요약/키워드: Elasticity imaging techniques

검색결과 13건 처리시간 0.024초

의료용 초음파탄성영상법 (Medical Ultrasonic Elasticity Imaging Techniques)

  • 정목근
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.573-584
    • /
    • 2012
  • 유방이나 전립선과 같은 연조직에서 발생하는 암이나 종양은 주위 조직보다 단단한 경향을 가진다. 하지만 초음파 B-mode 영상을 보면 암은 주위 조직과 거의 비슷하여 구별하기 어렵다. 따라서 조직의 단단한 정도를 영상화하면 더 정량적인 정보를 제공해 진단에 도움을 줄 수 있다. 초음파탄성영상은 측정하고자 하는 연조직에 기계적인 힘을 가하고 변형된 정도를 측정하여 영상화 한다. 탄성영상은 기존의 초음파 영상 진단기법과 더불어 종양을 진단하는 유용한 방법으로 자리매김하고 있다. 본 논문에서는 지금까지 발표된 다양한 탄성영상 방법을 분류하고 각 방법의 원리, 특성 등을 살펴본다.

Implementation of an Ultrasound Elasticity Imaging System

  • Cho Gae-Young;Yoon Ra-Young;Park Jeong-Man;Kwon Sung-Jae;Ahn Young-Bok;Bae Moo-Ho;Jeong Mok-Kun
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.117-124
    • /
    • 2006
  • Recently, active research has been going on to measure the elastic modulus of human soft tissue with medical ultrasound imaging systems for the purpose of diagnosing cancers or tumors which have been difficult to detect with conventional B-mode imaging techniques. In this paper, a real-time ultrasonic elasticity imaging system is implemented in software on a Pentium processor-based ultrasonic diagnostic imaging system. Soft tissue is subjected to external vibration, and the resulting tissue displacements change the phase of received echoes, which is in turn used to estimate tissue elasticity. It was confirmed from experiment with a phantom that the implemented elasticity imaging system could differentiate between soft and hard regions, where the latter is twice harder than the former, while operating at an adequate frame rate of 20 frames/s.

Strain elastography of palatal tumors in conjunction with intraoral ultrasonography, computed tomography, and magnetic resonance imaging: 2 case reports

  • Ogura, Ichiro;Toshima, Hiroo;Akashiba, Tohru;Ono, Junya;Okada, Yasuo
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.73-79
    • /
    • 2020
  • Computed tomography (CT) and magnetic resonance imaging (MRI) can be useful for the evaluation of palatal lesions, and strain elastography (performed together with intraoral ultrasonography) is a relatively new sonographic imaging modality. This report describes 2 clinical cases in which strain elastography was used to assess palatal tumors in conjunction with intraoral ultrasonography, CT, and MRI. In the first case, diagnosed as a myoepithelioma, the strain was determined to be 0.000% (strain of normal tissue, 0.556%). In the second case, diagnosed as an adenoid cystic carcinoma, the determined strain was 0.000% (strain of normal tissue, 1.077%). Therefore, we conclude that intraoral strain elastography can be useful for evaluating palatal lesions.

원자현미경의 나노 힘 측정을 이용한 생의학 연구에의 응용 (Atomic Force Microscopy Force Mapping Application in Biomedical Research)

  • 조상준;이동진;김은파;이동률
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.77-80
    • /
    • 2005
  • Local probe techniques such as scanning probe microscopy (SPM) or atomic force microscopy (AFM) extended our perception into ultra small world. Specially, the sense of touching was extended by AFM into the micro- and nanoworld and has provided complementary new insights of the microscopic world. In addition, touching objects is an essential step before trying to manipulate things. SPM as a touch sensor not only measure the mechanical properties but also detect different properties such as magnetic, electrical, ionic, thermal, chemical and biophysical properties in nanoscale and even less. Obtaining biophysical measurements, monitoring dynamics and processes together with high-resolution imaging of the biomolecules and cells with rather simpler sample preparation than any other techniques give great attractions to the scientists experimenting with biological samples. Among the many AFM capabilities we will specifically introduce the force plot which is used to measure tip-sample interactions and its application this time.

  • PDF

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

Feasibility of Spin-Echo Echo-Planar Imaging MR Elastography in Livers of Children and Young Adults

  • Kim, Jin Kyem;Yoon, Haesung;Lee, Mi-Jung;Kim, Myung-Joon;Han, Kyunghwa;Koh, Hong;Kim, Seung;Han, Seok Joo;Shin, Hyun Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.251-258
    • /
    • 2019
  • Purpose: To assess the feasibility of the use of spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) in livers of children and young adults. Materials and Methods: Patients (${\leq}20$ years old) who underwent 3T SE-EPI MRE were included retrospectively. Subjects were divided into three groups according to the purpose of the liver MRI: suspicion of fatty liver or focal fat deposition in the liver (FAT group), liver fibrosis after receiving a Kasai operation from biliary atresia (BA group), and hepatic iron deposition after receiving chemotherapy or transfusions (IRON group). Technical failure of MRE was defined when a stiffness map showed no pixel value with a confidence index higher than 95%, and the patients were divided as success and failure groups accordingly. Clinical findings including age, gender, weight, height, and body mass index and magnetic resonance imaging results including proton density fat fraction (PDFF), $T2^*$, and MRE values were assessed. Factors affecting failure of MRE were evaluated and the image quality in wave propagation image and stiffness map was evaluated using the appropriate scores. Results: Among total 240 patients (median 15 years, 211 patients in the FAT, 21 patients in the BA, and 8 patients in the IRON groups), technical failure was noted in six patients in the IRON group (6/8 patients, 75%), while there were no failures noted in the FAT and BA groups. These six patients had $T2^*$ values ranging from 0.9 to 3.8 ms. The image quality scores were not significantly different between the FAT and BA groups (P > 0.999), while the scores were significantly lower in the IRON group (P < 0.001). Conclusion: The 3T SE-EPI MRE in children and young adults had a high technical success rate. The technical failure was occurred in children with decreased $T2^*$ value (${\leq}3.8ms$) from iron deposition.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

Strain elastography of tongue carcinoma using intraoral ultrasonography: A preliminary study to characterize normal tissues and lesions

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.45-49
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Materials and Methods: Two patients with squamous cell carcinoma (SCC) who underwent quantitative strain elastography for the diagnosis of tongue lesions using intraoral ultrasonography were included in this prospective study. Strain elastography was performed using a linear 14 MHz transducer (Aplio 300; Canon Medical Systems, Otawara, Japan). Manual light compression and decompression of the tongue by the transducer was performed to achieve optimal and consistent color coding. The variation in tissue strain over time caused by the compression exerted using the probe was displayed as a strain graph. The integrated strain elastography software allowed the operator to place circular regions of interest (ROIs) of various diameters within the elastography window, and automatically displayed quantitative strain (%) for each ROI. Quantitative indices of the strain (%) were measured for normal tissues and lesions in the tongue. Results: The average strain of normal tissue and tongue SCC in a 50-year-old man was 1.468% and 0.000%, respectively. The average strain of normal tissue and tongue SCC in a 59-year-old man was 1.007% and 0.000%, respectively. Conclusion: We investigated the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Strain elastography using intraoral ultrasonography is a promising technique for characterizing and differentiating normal tissues and SCC in the tongue.

Point Shearwave Elastography의 유방 초음파에서의 적용: "S-Shearwave"를 이용한 감별진단의 초기경험 (Application of Point Shearwave Elastography to Breast Ultrasonography: Initial Experience Using "S-Shearwave" in Differential Diagnosis )

  • 이명환;김은경;이은주;김하얀;윤정현
    • 대한영상의학회지
    • /
    • 제81권1호
    • /
    • pp.157-165
    • /
    • 2020
  • 목적 S-Shearwave를 이용하여 유방 병변을 감별하는데 있어 최적의 cut-off 값과 종괴 내 위치를 알아보고 진단적 가치를 평가하고자 한다. 대상과 방법 연구 기간 동안 197명의 여성에서 225개의 유방 병변을 평가하였다. S-Shearwave 값은 초음파 기기에서 자동적으로 생성된 사각형의 region-of-interest로 측정하였다. 병변 내 서로 다른 네 군데에서 각각 세 번 측정하였으며 세 개의 중위 값 중 최대 값을 이용해 각각의 위치에서 최적의 cut-off 값을 계산하였다. 진단적 가치는 area under the receiving operator characteristics curve (이하 AUC)를 통해 평가하였다. 결과 총 225개의 유방 병변 중 156개(69.3%)는 양성, 69개(30.7%)는 악성이었다. 평균 SShearwave 값은 악성 병변이 양성 병변에 비해 유의미하게 높았다(108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa, p < 0.001). 하지만 병변 내 위치에 따른 값의 유의미한 차이는 없었다. Cut-off 값을 41.9 kPa로 사용했을 때, 민감도 85.7%, 특이도 63.9%, 정확도 70.7%, 양성예측도 51.7% 및 음성예측도 90.8%였다. 초음파와 S-Shearwave 간의 AUC는 유의미한 차이를 보이지 않았다(p = 0.179). 결론 S-Shearwave는 유방 병변의 감별진단을 하는데 grayscale 초음파에 필적하는 진단적 가치를 가진다.