• Title/Summary/Keyword: Ejection velocity

Search Result 75, Processing Time 0.04 seconds

Cardiac Response to Head-Out Water Immersion in Man

  • Choi, Jang-Kyu;Park, Won-Kun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.3
    • /
    • pp.253-261
    • /
    • 2000
  • Head-out water immersion induces marked increase in the cardiac stroke volume. The present study was undertaken to characterize the stroke volume change by analyzing the aortic blood flow and left ventricular systolic time intervals. Ten men rested on a siting position in the air and in the water at $34.5^{circ}C$ for 30 min each. Their stroke volume, heart rate, ventricular systolic time intervals, and aortic blood flow indices were assessed by impedance cardiography. During immersion, the stroke volume increased 56%, with a slight (4%) decrease in heart rate, thus cardiac output increased ${\sim}50%.$ The slight increase in R-R interval was due to an equivalent increase in the systolic and diastolic time intervals. The ventricular ejection time was 20% increased, and this was mainly due to a decrease in pre-ejection period (28%). The mean arterial pressure increased 5 mmHg, indicating that the cardiac afterload was slightly elevated by immersion. The left ventricular end-diastolic volume index increased 24%, indicating that the cardiac preload was markedly elevated during immersion. The mean velocity and the indices of peak velocity and peak acceleration of aortic blood flow were all increased by ${\sim}30%,$ indicating that the left ventricular contractile force was enhanced by immersion. These results suggest that the increase in stroke volume during immersion is characterized by an increase in ventricular ejection time and aortic blood flow velocity, which may be primarily attributed to the increased cardiac preload and the muscle length-dependent increase in myocardial contractile force.

  • PDF

Effect on Stratification due to Diffuser Shape in a Thermal Storage Tank (온도 성층축열조 가시화 및 실증분석에 관한 고찰)

  • Lee Young-Soo;Lee Sang-Nam;Kim Jong-Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.990-997
    • /
    • 2005
  • The stratified effect was investigated with three different types of diffuser shape in a thermal storage tank with variation of diffuser diameter, velocity, Froude number etc. Its effect was estimated by the degree of stratification. No matter of diffuser diameter and shape, the degree of stratification was the best as the Froude number gets closer to 1. In the case of a curved diffuser, when its diameter is a quarter of tank diameter and ejection velocity in a diffuser is approximately 0.2 m/s, the Froude number was almost 1. In the case of a flatted diffuser, when ejection velocity was 0.05 m/s, the Froude number was 1.5. Both cases which Froude number were nearer 1, showed the good degree of stratification.

Green Body Behaviour of High Velocity Pressed Metal Powder

  • Jonsen, P.;Haggblad, H.A.;Troive, L.;Furuberg, J.;Allroth, S.;Skoglund, P.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.22-23
    • /
    • 2006
  • High velocity compaction (HVC) is a production technique with capacity to significantly improve the mechanical properties of powder metallurgy (PM) parts. Investigated here are green body data such as density, tensile strength, radial springback, ejection force and surface flatness. Comparisons are performed with conventional compaction using the same pressing conditions. Cylindrical samples of a pre-alloyed water atomized iron powder are used in this experimental investigation. The HVC process in this study resulted in a better compressibility curve and lower ejection force compared to conventional quasi static pressing. Vertical scanning interferometry measurements show that the HVC process gives flatter sample surfaces.

  • PDF

Analysis of Ejection System of Projectile with Compressed Air (압축공기를 이용한 발사체 방출시스템 해석)

  • Kwon, Yong-Hun;Kim, Jun-Bum;Park, Warn-Gyu;Han, Myung-Chul;Ahn, Jae-Yul;Jung, Chan-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1488-1493
    • /
    • 2004
  • The purpose of the present work is to develop a compressed air discharging system to eject a projectile from the underwater. For the flow analysis of compressed air tank, projectile ejection tube, and pipe system, the air is assumed as an ideal gas, undergoing 1-dimensional axisymmetric, compressible flow, the Fanno flow analysis was applied. The commercial Fluent code was used to solve 3-D Navier-Stokes equation of the internal flow within the valve. The dynamics of the projectile within the ejection tube was assumed 1-degree of freedom. The calculations were performed to four cases of valve opening area ratio, i.e., 25%, 50%, 75%, and 100% opening area, at both depths of 10m and 50m. The results were shown as the figures of time variation of pressure of the compressed air tank and projectile ejection tube. The velocity and distance of the projectile were also predicted.

  • PDF

Effects of anesthesia on echocardiograms in myocardial infarcted dogs (심근경색 유발견에서 마취가 심초음파에 미치는 영향)

  • Yoon, Jung-hee;Sung, Jai-ki
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.669-685
    • /
    • 1997
  • The present study was performed to evaluate the effects of xylazine and tiletamine + zolazepam on echocardiograms before and after experimental myocardial infarctions in clinically normal dogs taken preliminary examinations related to cardiac function. The results are as follows. With xylazine administration, left ventricle end-diastolic dimension, left ventricle end-systolic dimension, left atrium/aorta, ejection time and velocity of circumferential fiber shortening increased and mitral valve CD slope, % delta D decreased(p<0.01). In tiletamine+zolazepam administered group, interventricular septum amplitude(p<0.01), mitral valve DE slope(p<0.05) and ejection time(p<0.01) decreased and left atrium/aorta, ejection time also decreased compared with xylazine group(p<0.01). In 48 hours after experimental myocardial infarction group, anterior aortic wall amplitude decreased compared with control, xylazine, tiletamine + zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end systolic dimension decreased compared with control(p<0.01). Left ventricular posterior wall amplitude decreased compared with control and tiletamine+zolazepam group(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior wall decreased compared with control(p<0.05). % delta D decreased compared with control and tiletamine+zolazepam group(p<0.01). Ejection time decreased compared with xylazine(p<0.01). Velocity of circumferential fiber shortening increased compared with control and tiletamine + zolazepam group(p<0.01). With xylazine administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude, posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-diastolic dimension increased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end-systolic dimension and left ventricular posterior wall end-diastolic dimension decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior. wall(p<0.05) and % delta D(p<0.01) decreased compared with control. Velocity of circumferential fiber shortening increased compared with tiletamine + zolazepam group(p<0.01). With tiletamine + zolazepam administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude decreased compared with control, xylazine and tiletamine+zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine+zolazepam group(p<0.01). Left ventricular posterior wall end-systolic dimension, left ventricular posterior wall end-diastolic dimension and interventricular septum amplitude decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % delta D decreased compared with control and tiletamine + zolazepam group(p<0.01). Ejection time decreased compared with xylazine group and velocity of circumferential fiber shortening increased compared withtiletamine+zolazepam group(p<0.01). Conclusively, echocardiography was proved to be a useful, diagnostic, non-invasive and simple method for establishing the diagnosis of myocardial infarction and evaluating the effects of drug on cardiac function before and after myocardial infarction.

  • PDF

Analysis of Electrostatic Ejection of Liquid Droplets in Manner of Drop-on-demand Using High-speed Camera (고속카메라를 이용한 Drop-on-demand 방식의 정전 액적 토출 분석)

  • Kim, Yong-Jae;Choi, Jae-Yong;Son, Sang-Uk;Kim, Young-Min;Lee, Suk-Han;Byun, Do-Young;Ko, Han-Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.128-133
    • /
    • 2007
  • An electrostatic inkjet head can be used for manufacturing processes of large display systems and printed circuit boards (PCB) as well as inkjet printers because an electrostatic field provides an external force which can be manipulated to control sizes of droplets. The existing printing methods such as thermal bubble and piezo inkjet heads have shown difficulties to control the ejection of the droplets for printing applications. Thus, the new inkjet head has been proposed using the electrostatic force. A numerical analysis has been performed to calculate the intensity of the electrostatic field using the Maxwell's equation. Also, experiments have been carried out to investigate the droplet movement using a downward capillary with outside diameter of $500{\mu}m$. Gravity, surface tension, and electrostatic force have been analyzed with high voltages for a drop-on-demand ejection. It has been observed that the droplet size decreases and the frequency of the droplet formation and the velocity of the droplet ejection increase with increasing the intensity of the electrostatic field using high-speed camera.

  • PDF

Sudden Death and Ventricular Arrhythmias in Heart Failure With Preserved Ejection Fraction

  • Jae Hyung Cho
    • Korean Circulation Journal
    • /
    • v.52 no.4
    • /
    • pp.251-264
    • /
    • 2022
  • Heart failure with preserved ejection fraction (HFpEF) accounts for approximately half of all heart failure (HF) cases. The prevalence of HFpEF is increasing due to an aging population with hypertension, diabetes mellitus, and obesity. HFpEF remains a challenging clinical entity due to a lack of effective treatment options. Traditional HF medications have not been shown to reduce mortality of patients with HFpEF, and an implantable cardioverter-defibrillator is not indicated due to normal ejection fraction. Sudden death is the most common mode of death in patients with HFpEF; however, the underlying mechanisms of sudden death are not fully elucidated. Although ventricular arrhythmias are responsible for the majority of sudden deaths in general, their contribution to sudden deaths in HFpEF patients is likely less significant. The mechanisms of ventricular arrhythmias in HFpEF are 1) reduced conduction velocity due to ventricular hypertrophy, 2) delayed repolarization due to potassium current down-regulation, 3) calcium leakage due to altered excitation-contraction coupling, and 4) increased ventricular fibrosis caused by systemic inflammation. Hypertension and subsequent ventricular hypertrophy reduce the conduction velocity in HFpEF hearts via heterogeneous distribution of connexin 43. Delayed repolarization caused by potassium current down-regulation in HFpEF hearts provides a window for early afterdepolarization to trigger ventricular arrhythmias. Altered excitation-contraction coupling in HFpEF can cause calcium to leak and trigger delayed afterdepolarization. Increased systemic inflammation and subsequent ventricular fibrosis provide substrates for re-entry. Further research is warranted to investigate the detailed mechanisms of ventricular arrhythmias in HFpEF.

Analysis of Electrostatic Ejection for Liquid Droplets (정전기력에 의한 액적 토출 분석)

  • Kim, Yong-Jae;Lee, Suk-Han;Byun, Do-Young;Son, Sang-Uk;Jeong, Dae-Won;Ko, Han-Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.505-508
    • /
    • 2006
  • An electrostatic ink jet head can be used for manufacturing processes of large display systems and printed circuit boards (PCB) as well as inkjet printers because an electrostatic field provides an external force which can be manipulated to control sizes of droplets. The existing printing methods such as thermal bubble and piezo inkjet heads have shown difficulties to control the ejection of the droplets for printing applications. Thus, the new inkjet head using the electrostatic force has been proposed in this study. In order to prove the theory of the developed electrostatic ink jet head, the applicable and basic theory has been studied using distilled water and water with sodium dodecyl surfate (SDS). Also, a numerical analysis has been performed to calculate the intensity of the electrostatic field using the Maxwell's equation. Furthermore, experiments have been carried out using a downward glass capillary with outside diameter of $500{\mu}m$. The gravity, surface tension, and electrostatic force have been analyzed with high voltages of 0 to 5kV. It has been observed that the droplet size decreases and the frequency of the droplet formation and the velocity of the droplet ejection increase with increasing the intensity of the electrostatic field. The results of the experiments have shown good agreement with those of numerical analysis.

  • PDF

Interaction of Laser Beam with PZT - Target and Observation of Laser - Induced Plume and Particle Ejection (Laser와 PZT - Target간의 반응과 그에 따른 Plume 형성 및 입자 방출에 관한 연구)

  • Lee, Byeong-U
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.93-102
    • /
    • 1996
  • Laser-induced plume and laser-target interaction during pulsed laser deposition are demonstrated for a lead zirconate titanate (PZT). A KrF excimer laser (wavelength 248nm) was used and the laser was pulsed at 20Hz, with nominal pulse width of 20ns. The laser fluence was~$16J/cm^2,$ with 100mJ per pulse. The laser-induced plasma plume for nanosecond laser irradiation on PZT target has been investigated by optical emission spectra using an optical multichannel analyzer(OMA) and by direct observation of the plume using an ICCD high speed photography. OMA analysis showed two distinct ionic species with different expansion velocities of fast or slow according to their ionization states. The ion velocity of the front surface of the developing plume was about $10^7$cm/sec and corresponding kinetic energy was about 100eV. ICCD photograph showed another kind of even slower moving particles ejected from the target. These particles considered expelled molten parts of the target. SEM morphologies of the laser irradiated targets showed drastic melting and material removal by the laser pulse, and also showed the evidence of the molten particle ejection. The physics of the plasma(plume) formation and particle ejection has been discussed.

  • PDF

Stemming Effect of the Crushed Granite Sand as Fine Aggregate at the Mortar Blasting Test (화강암 부순모래의 발파전색효과 연구)

  • Kim, Hak-Sung;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.21 no.4
    • /
    • pp.320-327
    • /
    • 2011
  • In this study, for stemming effect in blast of the mortar block body, the crushed granite sand as fine aggregate, which is waste rock obtained at the ○○ limestone mine, was investigated to compare with stemming materials such as sea sand, river sand, clayed soil and water can be acquired easily at the field. The mortar block body was manufactured with the dimensions of 50 cm width, 50 cm length and 70 cm height. The direct shear and sieve separator test were performed, and the properties of friction resistance were analyzed by the extrusion test for five stemming materials. Axial strain of steel bar and ejection velocity of stemming materials due to the explosive shock pressure in blasthole with the stemming length of 10 cm and 20 cm in the mortar blast test were measured by the dynamic data acquisition system. Among stemming materials, axial strain showed the largest value at the crushed granite sand as fine aggregate, and the ejection velocity was the smallest value at the stemming of water. The results has shown correlate with harden unit weight in blasthole, particle size distribution, shear resistance, and extrusion strength of stemming materials. The ejection velocity of stemming material at the mouth of blasthole and the axial strain of steel bar in the inside of blasthole tend to be inversely proportional to each other, represent exponentially.