• Title/Summary/Keyword: Ejection System

Search Result 131, Processing Time 0.024 seconds

Development of a Ejection Gas Generator for Precluding Erosive Burning by Using Bundle Cylindrical Grains (침식연소가 방지되는 사출용 다발 원통형 그레인 가스발생기 개발)

  • Oh, Seok-Jin;Cha, Hong-Seok;Jang, Seung-Gyo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.3
    • /
    • pp.69-76
    • /
    • 2012
  • An achieving method of highly progressive pressure gradient is presented to enhance the missile ejection system's performance by using a gas generator in the condition of preventing erosive burning. To obtain and confirm a stable burning, a ground burning test was performed to evaluate the new methods of a radial-hole and a multi-row propellant grain. The test results show that a radial-hole grain takes good effect on erosive burning and not on ejection performance. On the other hand, a multi-row grain which reduces the length-to-diameter ratio(L/D) of grain is very effective to prevent the erosive burning and to enhance the ejection performance simultaneously.

Development of a Ejection Gas Generator for precluding Erosive Burning by using Bundle Cylindrical Grains (침식연소가 방지되는 사출용 다발 원통형 그레인 가스발생기 개발)

  • Oh, Seok-Jin;Cha, Hong-Seok;Jang, Seung-Gyo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.432-439
    • /
    • 2011
  • An achieving method of highly progressive pressure gradient is presented to enhance the missile ejection system's performance by using a gas generator in the condition of preventing erosive burning. To obtain and confirm a stable burning, a ground burning test was performed to evaluate the new methods of a radial-hole and a multi-row propellant grain. The test results show that a radial-hole grain takes good effect on erosive burning and not on ejection performance. On the other hand, a multi-row grain which reduces the legnth-to-diameter ratio(L/D) of grain is very effective to prevent the erosive burning and to enhance the ejection performance simultaneously.

  • PDF

Wear Characteristics for Rod and Nozzle of Jetting Dispenser Driven by Dual Piezoelectric Actuators Under High Frequency with Phosphor-containing Liquid (형광체 함유 용액 고속 토출 조건에서의 듀얼 압전 디스펜서 공이와 노즐의 마모 특성 평가)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;An, Jun-Wook;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • An ultra-high precise ejection process is essential in a dispensing system for fabricating various precision parts such as a semiconductor, LED, and camera module. The size of such parts has been decreasing, which implies that a precise ejecting technique is required. A phosphor-containing liquid is ejected via a dispenser using dual piezoelectric actuators that are used for generating a high-speed dispensing mechanism. The rod and nozzle continuously contact in high speed to eject the liquid. However, the high-strength filler or phosphor in the liquid causes wear on the surfaces of the rod and nozzle during the dispensing process. As a result, the ejection reliability decreases as the wear on the surfaces increases. Therefore, it is necessary to estimate the wear characteristics of the rod and nozzle via an experiment and FE analysis. Reliability rests up to 1,000 cycles are conducted under relatively severe conditions. The flow rate and surfaces roughness of the rod and nozzle are measured in each ejection cycle. The surface images and wear volume are obtained before and after the tests and the ejection reliability is confirmed by measuring the flow rate of the liquid. The experimental results show that the ejection reliability is maintained up to 1,000k cycles; these results are validated by the simulation results.

A Heuristic Approach for an Layout and Sizing of an Ejector Pin (사출 금형의 밀핀 설계를 위한 경험적 설계 접근법)

  • 이희성;변철웅;이수홍
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.2
    • /
    • pp.112-121
    • /
    • 2004
  • As customers demands are rapidly changing, a product life cycle is getting shorter and a product model is forced to be changed frequently. An ejecting design system becomes more important for high productivity to eject a product in high temperature without any damage. For example, an ejector pin that is a key component of the system can cause high local stresses and strains in the molding at the time of ejection. The number, the size, and the location of pins are important to make a smooth ejection. Therefore we propose an analytical approach with the aid of designer’s experience to calculate a total release force and pressure distribution so that the number, the size, and the location of pins can be easily determined. As a part of the result, the design system is built by Intent! with AutoCAD 2000 and a video player deck example is presented to verify the approach.

Medical Management of Patients With Heart Failure and Reduced Ejection Fraction

  • Barry Greenberg
    • Korean Circulation Journal
    • /
    • v.52 no.3
    • /
    • pp.173-197
    • /
    • 2022
  • Treatment options for patients with heart failure (HF) with reduced ejection fraction (HFrEF) have expanded considerably over the past few decades. Whereas neurohormonal modulation remains central to the management of patients with HFrEF, other pathways have been targeted with drugs that have novel mechanisms of action. The angiotensin receptor-neprilysin inhibitors (ARNIs) which enhance levels of compensatory molecules such as the natriuretic peptides while simultaneously providing angiotensin receptor blockade have emerged as the preferred strategy for inhibiting the renin angiotensin system. Sodium glucose cotransporter 2 (SGLT2) inhibitors which were developed as hypoglycemic agents have been shown to improve outcomes in patients with HF regardless of their diabetic status. These agents along with beta blockers and mineralocorticoid receptor antagonists are the core medical therapies for patients with HFrEF. Additional approaches using ivabradine to slow heart rate in patients with sinus rhythm, the hydralazine/isosorbide dinitrate combination to unload the heart, digoxin to provide inotropic support and vericiguat to augment cyclic guanosine monophosphate production have been shown in well-designed trials to have beneficial effects in the HFrEF population and are used as adjuncts to the core therapies in selected patients. This review provides an overview of the medical management of patients with HFrEF with focus on the major developments that have taken place in the field. It offers prospective of how these drugs should be employed in clinical practice and also a glimpse into some strategies that may prove to be useful in the future.

The Analysis of Drop-On-Demand Characteristic of Electrostatic Field Induced Inkjet Head System with Carbon Nano Tube (CNT) Ink (정전기장 유도된 잉크젯 프린터 헤드를 이용한 탄소나노튜브 잉크의 Drop-On-Demand 특성 연구)

  • Choi, J.Y.;Kim, Y.J.;Son, S.U.;Kim, Y.M.;Byun, D.Y.;Ko, H.S.;Lee, S.H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1445-1449
    • /
    • 2007
  • This paper presents the DOD (Drop-On-Demand) characteristic using the electrostatic field induced inkjet printing system. In order to achieve the DOD characteristic of electrostatic field induced inkjet printing, applied the bias voltage of 1.4 kV and the pulse voltage of $2.0\;kV\;{\sim}\;2.7\;kV$ using high voltage pulse generator. Electrostatic field induced droplet ejection is directly observed using a high-speed camera and for investigated DOD characteristic, CNT ink used. The electrostatic field induced inkjet head system has DOD characteristic using pulse generator which can be applied pulse voltage. The bias voltage has a good condition which form meniscus and has micro dripping mode for small size micro droplet. Also, the droplet size decreases with increasing the applied pulse voltage. This paper shows DOD characteristic at electrostatic field induced inkjet head system, Therefore. electrostatic DOD inkjet head system will be applied industrial area comparing conventional electrostatic inkjet head system.

A Study for the Gallbladder Stone on the Dietary Factors (식이요인에 따른 담석형성에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.391-397
    • /
    • 2007
  • Background/Aims : Gallbladder(GB) stone is the most common disease in the biliary system, and the incidence is gradually increasing in Korea. This change may include rapidly proceeding urbanization and changing food factor. We performed this study to investigate related GB stones and contraction of GB as dietary factors. Methods : We investigated 129 subjects(mean age : 47 years). GB stone group is 9 subjects(M: 2, F: 7) in Namyangju-si. Control group without GB stone is 18 subjects(M: 6, F: 12) in Wi-do island. For subjects without GB stone, diabetes mellitus decide 4(M: 2, F: 2) and then each after eat flesh and meat of estimated by experimental group ejection fraction rate(%). Results : Ejection fraction rate of GB were different between meat and fishes intake. When ate the meat in experiment for hypothetical verification, when become ejection fraction rate of meal GB 210 minutes, was the highest and when ate fish, the ejection fraction rate of GB was the highest in meal 120 minutes. Conclusions : After meats intaking the bile inside the GB is stagnant long and the GB stone is formed. We studied the results GB motility may important play a role on GB stone formation.

  • PDF

Evaluation of micro jet nozzle using finite elements method (유한요소해석을 이용한 마이크로 분사 노즐 특성 평가)

  • Lim, Dong-Wook;Choi, Doo-Sun;Kim, Tae-min;Park, Jung-Rae;Park, Kyu-Bag;Ham, Hwi-Chan;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • In the drug delivery system industry, the technology with even split injection becomes important for maximizing efficiency and minimizing the side effects. In conventional drug delivery system, infection can occur due to pain and splashing. Also, various applications are impossible due to disposable use, and it is the reason to avoid to use this system because of the complexity of the driving method. Therefore, in this study, a painless drug delivery device is developed for non-pain with electrical insulation breakdown method. Finite elements analysis was used to evaluate the ejection characteristics of drugs according to the shape of the micro ejection nozzle. The effect of the number of holes in the micro nozzle, the length of the nozzle and the inner shape of the nozzle on the drug discharge characteristics were analyzed.