• Title/Summary/Keyword: Ejection Angle

Search Result 34, Processing Time 0.049 seconds

Evaluation of Various Cardiae Indices and ROC Analysis in Coronary Artery Disease Employing Resting ECG Gated Blood Pool Scan (관상동맥질환에서 휴식기 심전도게이트혈액풀스캔을 이용한 각종 심기능 지표들의 평가 및 ROC 분석)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.40-48
    • /
    • 1992
  • Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consitently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used $^{99m}Tc-labeled$ RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normls and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.

  • PDF

Calculation of Sputter Yield using Monte Carlo Techniques (몬테카를로 방식에 의한 스퍼터율 계산에 관한 연구)

  • 반용찬;이제희;원태영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.59-67
    • /
    • 1998
  • In this paper, a rigorous three-dimensional Monte Carlo approach to simulate the sputter yield as a function of the incident ion energy and the incident angle as well as the atomic ejection distribution of the target is presented. The sputter yield of the target atom (Cu, Al) has been calculated for the different species of the incident atoms with the incident energy range of 10 eV ~ 100 KeV, which coincides with the previously reported experimental results. According to the simulation results, the calculated sputter yield tends to increase with the amount of the energy of the incident atoms. Our simulation revealed that the maximum sputter yield can be obtained for the incident atom with 10 KeV for the heavy ion, while the maximum sputter yield for the light ion is for the incident atoms with an energy less than 1 KeV. The sputter yield increases with angle of incidence and seems to have the maximum value at 68$^{\circ}$. For angular distributions of the sputtered particle, the atoms in the direction normal to the surface increase with angle of incidence. Furthermore, we has conducted the parallel computation on CRAY T3E supercomputer and built a GUI(Graphic User Interface) system running the sputter simulator.

  • PDF

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Effect of Thermal Treatment Conditions on Shapes of Inkjet Printed Silver Patterns (열처리 조건이 잉크젯 인쇄된 실버 패턴의 형상에 미치는 영향)

  • Shin, Kwon-Yong;Kang, Kyung-Tae;Cho, Young-June;Lee, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1712-1713
    • /
    • 2011
  • Inkjet technology have many merits in plenty of industrial applications. However, deposited droplet has a very critical issue that is coffee ring effect, for the application to an industrial manufacturing process. To remove the coffee ring effect, the effect of thermal treatment conditions on shapes of inkjet printed silver patterns were investigated in various surface condition. The surface changes were characterized by the contact angle measurement. Droplets from a 50 ${\mu}m$ nozzle were printed on the substrate after optimizing the ejection of individual droplets. Ink with a high boiling point of main solvent results in coffee ring effect. This result implies that the dominant factor that determines the shape of droplet is the drying conditions of main solvent of silver nanoparticle colloidal ink. As a results, selecting a proper thermal treatment conditions is very crucial for better shapes of inkjet printed silver nanoparticle colloidal patterns.

  • PDF

A Mixing Characteristic of De-NOx Reducing Agent for Flue Gas in Thermal Power Generation (화력발전 배가스 탈질 환원제의 혼합특성)

  • Choi, H.S.;Kim, K.T.;Kim, S.J.;Jeong, S.H.;Song, Y.H.;Hong, S.H.;Lee, J.Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.79-85
    • /
    • 2006
  • In this study, to increase the mixing between flue gas and reducing agent, new shapes of $NH_3$ ejection nozzles are designed and experimentally and numerically tested. The nozzles have six holes perpendicular to the ambient flue gas flow and the tilting angle between direction of ambient flow and the hole axis is varied. To evaluate the mixing efficiency of the proposed nozzles, numerical and experimental tests are applied to several flow conditions comparing with single hole nozzle, which is commonly used in conventional SCR process. From the results the nozzle with tilted multi-holes has the large region of high turbulent intensity compared with conventional single hole nozzle. This is originated from the high vorticity near the upstream of the jet flow issuing from the hole. The high turbulent intensity and vorticity magnitude lead to enhanced mixing between flue gas and reducing agent. Hence, the most suitable moral ratio between NOx and reducing agent for the catalytic reaction can be obtained on behalf of the intensified scalar mixing within shorter physical mixing length.

  • PDF

Phase Image Analysis in Conduction Disturbance Patients (심실내 전도장애 환자에서의 $^{99m}Tc$-RBC Gated Blood-Pool Scintigraphy을 통한 Phase Image Analysis)

  • Kwak, Byeng-Su;Choi, Si-Wan;Kang, Seung-Sik;Park, Ki-Nam;Lee, Kang-Wook;Jeon, Eun-Seok;Park, Chong-Hun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 1994
  • It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of it's events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of $^{99m}Tc$-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls ($44.4{\pm}13.9%$ vs $69.9{\pm}4.2%,\;2.48{\pm}0.98$ vs $3.51{\pm}0.62,\;1.76{\pm}0.71$ vs $3.38{\pm}0.92$, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls ($20.6{\pm}18.1$ vs $8.6{\pm}1.8,\;22.5{\pm}9.2$ vs $16.0{\pm}3.9,\;95.7{\pm}31.7$ vs $51.3{\pm}5.4$, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the Wolff-parkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls ($10.6{\pm}2.6$ vs $8.6{\pm}1.8$, p<0.05, $69.8{\pm}11.7$ vs $51.3{\pm}5.4$, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventricles in patients with normal conduction, but markedly delayed phase in the left ventricle of patients with LBBB. 6) In 13 cases of WPW syndrome, the site of preexcitation could be localized in 10 cases (77%) by phase image analysis. Therefore, it can be concluded that phase image analysis can provide an accurate noninvasive method to detect the mechanical consequences of a wide variety of abnormal electrical activation in ventricles.

  • PDF

Estimation of Safety Area for Intercept Debris by Using Modeling and Simulation (탄도탄 요격시험 안전구역 산출을 위한 모델링 및 시뮬레이션)

  • Lee, Sungkyun;Go, Jinyong;Han, Yongsu;Kim, Changhwan
    • Journal of the Korea Society for Simulation
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • The ballistic missile threat continues to increase with the proliferation of missile technology. In response to this threat, many kinds of interceptors have been emphasized over the years. For development of interceptor, systematic flight tests are essential. Flight tests provide valuable data that can be used to verify performance and confirm the technological progress of ballistic missile defense system including interceptor. However, during flight tests, civilians near the test region could be risk due to a lot of intercept debris. For this reason, reliable estimate of safety area for the flight tests should be preceded. In this study, prediction of safety area is performed through modeling and simulation. Firstly, behaviors of ballistic missile and interceptor are simulated for those entire phase including interception to obtain the relative intercept velocity and the relative impact angle. By using obtained data of kinetic energy, the fragment ejection velocity is calculated and fragment trajectories are simulated by considering drag, gravity and wind effects. Based on the debris field formation and hazard evaluation of debris, final safety area is calculated.

The advancing techniques and sputtering effects of oxide films fabricated by Stationary Plasma Thruster (SPT) with Ar and $O_2$ gases

  • Jung Cho;Yury Ermakov;Yoon, Ki-Hyun;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.216-216
    • /
    • 1999
  • The usage of a stationary plasma thruster (SPT) ion source, invented previously for space application in Russia, in experiments with surface modifications and film deposition systems is reported here. Plasma in the SPT is formed and accelerated in electric discharge taking place in the crossed axial electric and radial magnetic fields. Brief description of the construction of specific model of SPT used in the experiments is presented. With gas flow rate 39ml/min, ion current distributions at several distances from the source are obtained. These was equal to 1~3 mA/$\textrm{cm}^2$ within an ion beam ejection angle of $\pm$20$^{\circ}$with discharge voltage 160V for Ar as a working gas. Such an extremely high ion current density allows us to obtain the Ti metal films with deposition rate of $\AA$/sec by sputtering of Ti target. It is shown a possibility of using of reactive gases in SPT (O2 and N2) along with high purity inert gases used for cathode to prevent the latter contamination. It is shown the SPT can be operated at the discharge and accelerating boltages up to 600V. The results of presented experiments show high promises of the SPT in sputtering and surface modification systems for deposition of oxide thin films on Si or polymer substrates for semiconductor devices, optical coatings and metal corrosion barrier layers. Also, we have been tried to establish in application of the modeling expertise gained in electric and ionic propulsion to permit numerical simulation of additional processing systems. In this mechanism, it will be compared with conventional DC sputtering for film microstructure, chemical composition and crystallographic considerations.

  • PDF

Halo CME mass estimated by synthetic CMEs based on a full ice-cream cone model

  • Na, Hyeonock;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.43.1-43.1
    • /
    • 2021
  • In this study, we suggest a new method to estimate the mass of a halo coronal mass ejection (CME) using synthetic CMEs. For this, we generate synthetic CMEs based on two assumptions: (1) the CME structure is a full ice-cream cone, (2) the CME electron density follows a power-law distribution (ρcme0r-n). The power-law exponent n is obtained by minimizing the root mean square error between the electron number density distributions of an observed CME and the corresponding synthetic CME at a position angle of the CME leading edge. By applying this methodology to 57 halo CMEs, we estimate two kinds of synthetic CME mass. One is a synthetic CME mass which considers only the observed CME region (Mcme1), the other is a synthetic CME mass which includes both the observed CME region and the occulted area larger than 4 solar radii (Mcme2). From these two cases, we derive conversion factors which are the ratio of a synthetic CME mass to an observed CME mass. The conversion factor for Mcme1 ranges from 1.4 to 3.0 and its average is 2.0. For Mcme2, the factor ranges from 1.8 to 5.0 with the average of 3.0. These results imply that the observed halo CME mass can be underestimated by about 2 times when we consider the observed CME region, and about 3 times when we consider the region including the occulted area. Interestingly these conversion factors have a very strong negative correlation with angular widths of halo CMEs.We also compare the results with the CME mass estimated from STEREO observations.

  • PDF