• Title/Summary/Keyword: Effluent discharge

Search Result 207, Processing Time 0.023 seconds

A Study on the Management System Improvement of Effluent Water Qualities for Public Sewage Treatment Facilities in Korea (우리나라 공공하수처리시설의 방류수 수질 관리체계 개선방안 고찰 - 미국, 일본, 유럽의 공공하수처리시설 방류수 수질 관리제도를 중심으로 -)

  • Jeong, Donghwan;Choi, Incheol;Cho, Yangseok;Chung, Hyenmi;Kwon, Ohsang;Yu, Soonju;Yeom, Icktae;Son, Daehee
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.4
    • /
    • pp.296-314
    • /
    • 2014
  • In recent years, Ministry of Environment (MOE) has been implementing a phased strengthening of the effluent standards for sewage treatment plants. In this regard, a comprehensive system should be developed to help check the appropriateness of such standards by specifying the grounds for standard-setting and investigating the current operation of sewage treatment plants clearly. It is necessary to establish a new standard-setting system for the effluent that is in a closer connection with the environmental criteria and rating systems. In the United States, the federal government provides guidelines on the least provisions and requirements for the Publicly Owned Treatment Works (POTWs). Local governments set the same or stricter guidelines that reflect the characteristics of each state. In Japan, the sewage treatment plants are subject to both the effluent standards and the discharge acceptable limits to pubic waters under the sewerage law. Specific requirements and limits are set in accordance with local government regulations. The European Union imposes sewage treatment plants with different provisions for effluent standards, depending on the sensitivity of public waters to eutrophication. The effluent standards for sewage treatment plants are classified by pollutant loads discharged to receiving waters. MOE also needs to introduce systems for setting new parameter standards on a POTW effluent by applying statistical means and treatment efficiencies or optimal treatment techniques, as seen in the cases of the US National Pollutant Discharge Elimination System (NPDES) or the EU Integrated Pollution Prevention and Control (IPPC).

Reliability Assessment of Industrial Wastewater Treatment Plant (특정제조업 폐수처리시설에 대한 신뢰성 평가)

  • Yang, Hyung-Jae;Kim, Jae-Hoon;Lee, Sung-Jong
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2007
  • A wastewater treatment plant, operating process is physico-chemical/biological activated sludge attached sand filtration, was selected to evaluate effluent quality and pollutants removal efficiencies consideration for deriving the technology-based effluent limitation for petroleum refining industry discharge. The results of influent and effluent analysis were as follows: Average effluent quality were 0.076mg/l of copper, 0.084mg/l of lead, 0.036mg/l of zinc, 0.005mg/l of nickel and 0.004mg/l of cadmium, and the range of coefficient of reliability from 0.007 of copper to 1.0 of lead. Also, 95% of reliability, 0.112, 0.15, 0.063, 0.015 and 0.009mg/l, respectively, were remarkably lower than their effluent limitations. And to reach 95% reliability of effluent limitation at cleanness area, designed effluent quality of copper, lead, zinc and cadmium should be 0.268, 0.099, 0.526 and 0.008mg/l, respectively.

Numerical Simulation for Effluent Transport According to Change in Depth of Marine Outfall in Masan Bay Using a Particle Tracking Model (입자추적모델을 이용한 마산만 해중방류구 수심 변화에 따른 방류수 거동 수치모의)

  • Kim, Jin Ho;Jung, Woo sung;Kim, Dong-Myung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.6
    • /
    • pp.954-959
    • /
    • 2022
  • Marine outfalls are used to discharge treated liquid effluents to the environment. An efficiently designed, constructed and operated marine outfall effectively dilutes the discharged effluent, thereby reducing the risk to biota and humans dependent upon the marine environment. In this study, we investigated the effluent transport from a marine outfall at different depths in Masan Bay. A particle-tracking model was used to predict the dispersion of effluent. The model results indicate that some particles released from a depth of 13 m move to the inner area of Masan Bay within 48 h. As the release depth increases after 48 h, the particles move further southward. This suggests that effluent from the outer area of Masan Bay can affect the inner area, and that this effect can be reduced by increasing the depth of effluent release.

Spatiotemporal Distribution of Macrobenthic Communities in the Coastal Area of Uljin and Its Relation to Environmental Variables (울진 주변 해역 대형저서동물 군집의 시·공간 분포와 환경요인과의 관계)

  • Yu, Ok-Hwan;Paik, Sang-Gyu;Lee, Hyung-Gon;Lee, Jae-Hac
    • Ocean and Polar Research
    • /
    • v.33 no.4
    • /
    • pp.421-434
    • /
    • 2011
  • Although thermal effluent from coastal power plants affects marine ecosystems, few studies have examined the spatiotemporal distribution of macrobenthic communities in a coastal area of Korea with thermal discharge. This study analyzed the species composition and abundance of a macrobenthic community in relation to environmental variables for a period of 1 year. In total 334 macrobenthic faunal species were collected; the mean density was 3,221 ind/$m^2$. The number of species and the density of macrobenthic fauna increased with distance from the thermal discharge site. Cluster analysis indicated that the macrobenthic community could be divided into two groups: group I in shallow (< 30 m deep) and group II in the outer areas (> 30 m deep). Group I showed the lowest species density and diversity. Four polychaetes, including Magelona japonica, Spiophanes bombyx, Scolotoma longifolia and Chaetozone setosa, all of which have been dominant species since 1987, exhibited higher mean densities in the area distant from the thermal discharge (the outer and north areas). Conversely, the warm-adapted and opportunistic species, such as the amphipods Urothoe convexa and Mandibulophoxus mai, the bivalve Felaniella sowerbyi, and the polychaete Rhynchospio sp., were more abundant in the thermal discharge region. The results of this study indicate that thermal effluent influences macrobenthic communities in the shallow area, while other environmental variables, such as depth, sediment grain size, and TOC, are more important determinants of the macrobenthic communities in deeper regions (> 30 m deep).

A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment (고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구)

  • Lee, Min-Gyu;Chung, Geun-Sik;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam (전자선을 이용한 하수처리장 방류수내 대장균군 살균)

  • Kim, Yuri;Han, Bumsoo;Kim, Jinkyu;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

Effect of Length of Outfall Structure on Reattachment of Thermal Discharge (온수방류의 귀환에 방류구 길이의 영향)

  • Yoon, Tae-Hoon;Yook, Woon-Soo;Yi, Yong-Kon
    • Water for future
    • /
    • v.27 no.3
    • /
    • pp.123-134
    • /
    • 1994
  • The reattachment of buoyant effluent to shore in a crossflow is investigated experimentally. The effluent is produced by discharging warm water through projecting side channel into a confined cross-flow of the same depth. In the projecting effluent, the size of recirculating region, which is formed by defleted thermal plume on the lee of the effluent, tends to increase, but the maximum temperature decreases in the direction of the crossflow and it has more even transverse spreading compared to non-projecting type. The heat flux across the crossflow is found to be independant of the projected length of the side channel under relatively low buoyancy flux on the contrary to high buoyancy flux. The reattachment of the effluent can be specified by both velocity ratio and densimetric Froude number, whereas only the velocity ratio is governing factor to the reattachment of the effluent in the case of non-projecting type.

  • PDF

Use of Chemical and Biological Agents to Improve Water Quality of Effluent Discharge from Abattoirs

  • Goopy, J.P.;Murray, P.J.;Lisle, A.T.;Al Jassim, R.A.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.1
    • /
    • pp.137-145
    • /
    • 2004
  • Intensive animal industries create large volumes of nutrient rich effluent which, if untreated, has the potential for substantial environmental degradationand to recover valuable nutrients that would otherwise be lost. Members of the family Lemnaceae are widely used in lagoon systems, to achieve inexpensive and efficient remediation of effluent. Only limited research has been conducted into their growth in highly eutrophic media and there has been little done to systematically distinguish between different types of media. This study examined the growth characteristics of duckweed in abattoir effluent and explored possible ways of ameliorating the inhibitory factors to growth on this medium. A series of pot trials was conducted to test the tolerance of duckweed to abattoir effluent partially remediated by a sojourn in anaerobic fermentation ponds, both in its unmodified form and after the addition of acid to manipulate pH, and the addition of bentonite. Unmodified abattoir effluent was highly toxic to duckweed, even at dilutions of 3:1. Duckweed remained viable and grew sub-optimally in simplified media with total ammonia nitrogen (TAN) concentrations of up to 100 mg/L. Duckweed grew vigorously in effluent diluted 1:4 v/v, containing 56 mg TAN/L when modified by addition of acid (to decrease pH to 7) and bentonite at 0.5%. The results of this study suggest that bentonite plays an important role in modifying the toxicity of abattoir effluent to duckweed.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

하수처리장 방류수에 용존된 무기화학종의 연속계측자료를 이용한 하천유량, 유속 및 방류량 추적

  • Kim, Gang-Ju;Han, Chan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.3-6
    • /
    • 2001
  • Various Parameters such as stream velocities, discharges, and dispersion coefficients of dissolved solutes were estimated by fitting 1-D nonreactive solute transport model to the time-series chemistry data. This study was done for the reaches of Mankyung River lower than the Jeonju Wastewater Treatment Plant (Jeonju WTP). Korea. Concentrations of inorganic chemicals in the stream waters are strongly influenced by mixing with the chemically distinct effluent from Jeonju WTP. Sulfate, EC. and the total major cation were proved to be nearly conservative in the study area front their relationships with chloride, the conservative chemical species. The solute transport model was constrained to the time-series concentrations for these 4 conservative species. The variations of concentration and discharge of Jeonju WTP were used as input parameters, and the stream velocities, dispersion coefficients, and concentrations and discharges of some inflows were optimized. The differences between the observed arid simulated values for alkalinities and nitrates are inversely correlated and show diurnal fluctuations, indicating the photosynthesis. The parameters obtained front this mode] range from 550 to 774 kcmd (stream discharge at the outlet of the study area), from 0.06 to 0.10 m/sec (flow velocity), and from 0.7 to 6.4 m$^2$/sec (dispersion coefficient). The history of Jeonju WTP discharge was well predicted when optimized, indicating the validity of the model results.

  • PDF