• 제목/요약/키워드: Effluent

검색결과 1,975건 처리시간 0.026초

방류수질 예측을 위한 AI 모델 적용 및 평가 (Application and evaluation for effluent water quality prediction using artificial intelligence model)

  • 김민철;박영호;유광태;김종락
    • 상하수도학회지
    • /
    • 제38권1호
    • /
    • pp.1-15
    • /
    • 2024
  • Occurrence of process environment changes, such as influent load variances and process condition changes, can reduce treatment efficiency, increasing effluent water quality. In order to prevent exceeding effluent standards, it is necessary to manage effluent water quality based on process operation data including influent and process condition before exceeding occur. Accordingly, the development of the effluent water quality prediction system and the application of technology to wastewater treatment processes are getting attention. Therefore, in this study, through the multi-channel measuring instruments in the bio-reactor and smart multi-item water quality sensors (location in bio-reactor influent/effluent) were installed in The Seonam water recycling center #2 treatment plant series 3, it was collected water quality data centering around COD, T-N. Using the collected data, the artificial intelligence-based effluent quality prediction model was developed, and relative errors were compared with effluent TMS measurement data. Through relative error comparison, the applicability of the artificial intelligence-based effluent water quality prediction model in wastewater treatment process was reviewed.

하천 수질에 대한 36시간 연속 모니터링 기법 연구 (36hrs Continuous Monitoring Methodology for Effluent and Receiving Water Quality)

  • 박정규;정홍배;문성환;류태권;류제영;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.153-159
    • /
    • 2001
  • The main point source of pollution of the Keumho river in Taegu, Korea, stems from waste from the areas of industrial complexes . Although it is widely accepted that pollutants in waste water negatively effects general water quality, it is difficult to evaluate the effluent effect because of varying conditions in ambient water and inconclusive knowledge of causative pollutants. To analyze the water in relation to the industrial effluent in the area, pH. temperature, conductivity, and Microtox toxicity of various river samples were measured. Water samples were collected every 2 hours for 36 hours from Keumho river and Dalseo stream. Data from continuous monitoring for 36 hours showed that effluent in Keumho river originated from Dalseo stream, which is near adjacent to industrial complexes. Change in toxicity and other factors tested during the 36 hours indicated that continuous monitoring was necessary for a satisfactory effluent toxicity test Furthermore, in addition to water quality monitoring, it was concluded that sediment toxicity also needed to evaluate effluent effects.

  • PDF

농업용수재이용을 위한 하수처리장 현황조사 (Investigation of Effluent of Wastewater Treatment Plants for Agriculture Reuse)

  • 이광야;김해도;정광근;이종남
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.521-526
    • /
    • 2005
  • Water Quality of effluent from wastewater treatment plants was reviewed to reuse effluent for agricultural water as alternative water resources. Among 2004, wastewater treatment plants, 19 plants are found to be used as wastewater resources applicable to irrigation. The total effluent capacities are 9,293 thousand $m^3$per day, which may be used to irrigate paddy fields. In order to know how much the effluent can be use for agricultural water, we classified the effluent according to the river basin area and evaluated the water quality of the effluent.

  • PDF

유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

산업폐수에 대한 이화학적 분석과 물벼룩 생태독성의 비교 (Comparison between Ecotoxicity using Daphnia magna and Physiochemical Analyses of Industrial Effluent)

  • 이선희;이학성
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1269-1275
    • /
    • 2014
  • Ecotoxicity assessments with the physiochemical water quality items and the bioassay test using Daphnia magna were conducted for 18 selected effluents of 6 industrial types (metal processing, petroleum refining, synthetic textile manufacturing, plating, alcohol beverage manufacturing, inorganic compound manufacturing) being detected toxicity from industrial effluent in Ulsan city, and the interrelationship between total toxic unit (${\Sigma}TU$) and concentrations of Water Quality Conservation Act in Korea were investigated. The average toxic unit(TU) of effluents for 6 industrial types displayed the following ascending order: petroleum refining (0.2) < synthetic textile manufacturing (0.6) < alcohol beverage manufacturing (0.9) < metal processing (1.3) ${\leq}$ inorganic compound manufacturing (1.3) < plating (3.0). These values were less than effluent permission standard. Based on the result of substances causing ecotoxicity, the correlation analysis was not easy because most of heavy metals were not detected or were less than effluent permission standard. Toxicological assessment of industrial effluent was suitable for the evaluation of the mixture toxicity for pollutant. The whole effluent toxicity test using a variety of species was needed for the evaluation of industrial wastewater.

Genotoxic and Neurotoxic Potential in Marine Fishes Exposed to Sewage Effluent from a Wastewater Treatment Plant

  • Park, So-Yun;Kim, So-Jung;Rhee, Yong;Yum, Seung-Shic;Kwon, Tae-Dong;Lee, Taek-Kyun
    • Molecular & Cellular Toxicology
    • /
    • 제5권3호
    • /
    • pp.265-271
    • /
    • 2009
  • Concentrations of industrial, agricultural and natural chemicals have been increasing in secondary effluents without their combined sub-lethal effects having been elucidated. In this study, two assays (the comet and acetylcholinesterase assays) were combined to evaluate the genotoxic and neurotoxic effects of effluent from the Noksan wastewater treatment plant (WWTP) on two local marine fish species (flounder and sea eel). The fish were exposed to WWTP secondary effluent that had been diluted with filtered seawater to final concentrations of 1%, 10% and 50%. Analysis of fish samples collected 3 and 5 days after exposure showed that DNA damage occurred in flounder exposed to 50% effluent and in sea eels exposed to 10% or 50% effluent. Furthermore, it was found that acetylcholinesterase (EC:3.1.1.7, AChE) activity decreased in both species when exposed to 10% effluent, indicating the presence of large amounts of genotoxic and neurotoxic chemicals in the effluent. Our results indicate that the comet and AChE assays are promising tools for biomonitoring of secondary effluents.

유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로 (A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System)

  • 정동환;조양석;김영석;안경희;정현미;권오상
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

Spread Patterns of Thermal Effluent Discharged From Young-Kwang Nuclear Power Plant Using Remote Sensing Data

  • Han J. G.;Yeon Y. K.;Chi K. H.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.331-335
    • /
    • 2004
  • This study is focused to analyze the movement of thermal effluent dischargeed from nuclear power plant by season, ebb and flow, and before and after foundation of tide embankment using thermal infrared band image of 28 scenes observed from Landsat from 1987 to 2004, which is the early stage of operation of young-kwang nuclear power plant. In diffusion of thermal effluent discharge by seasons, spring and summer is spreading further than autumn and winter. It is considered to distribute widely mixed with thermal effluent discharge and hot water, which is distributed naturally along the seaside. It is known the fact that tidal currents control the direction of diffusion of thermal effluent discharge by the change of ebb and flow. Namely, it is distributed widely on the Southwest direction along the seaside by tidal currents when ebb and, it is moved widely on the Northeast direction along the seaside by tidal current when flood. However, in the early stage of flood current, the mainstream of thermal effluent discharge is spread on Southwest direction and, the direction is changed on North­east way when the latter period of flood current. Similarly, in the early stage of ebb current, the mainstream of thermal effluent discharge is spread on Northeast direction and, the direction is changed on Southwest direction when the latter period of ebb current. As the result of comparing to the diffusion pattern of thermal effluent discharge before and after the foundation of seawall, discharged thermal effluent from the drain of plant by the foundation of dike is shown as curved circle pattern on Northeast to West direction from the ending portion of the seawall.

  • PDF

연못을 이용한 동절기 인공습지 오수처리수의 추가 처리 (Pond System for Further Polishing of Constructed Wetland Effluent during Winter Season)

  • 윤춘경;전지홍;김민희;함종화
    • 한국농공학회지
    • /
    • 제44권4호
    • /
    • pp.139-148
    • /
    • 2002
  • Pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent from December 2000 to June 2001. The wetland system used for the experiment was highly effective to treat the sewage during the growing season, but it was less effective and its effluent was still high to discharge to the receiving water body. Therefore, the wetland effluent may need further treatment to prevent water quality degradation. Pond system could be used to hold and further polish the wetland effluent during the winter season and ots feasibility was evaluated in this study. Additional water quality improvement was apparent in the pond system during winter season, and the pond effluent could be good enough to meet the effluent water quality standards if it is properly managed. Timing of the pond effluent discharge appears to be critical for pond system management because it is a closed system and whole water quality constituents are affected by physical, chemical, and biological pond environments. Once algae started to grow in mid-April, constituents in the pond water column interact each other actively and its control becomes more complicated. Therefore, upper layer of the pond water column which is clearer than the lower layer my need be discharged in March right after ice cover melted. In the experiment, water quality of the upper water column was markedly clear in March than ant other times probably because of freezing-thawing effect. The remaining lower water column could be further treated by natural purification as temperature goes up or diluted with better quality of wetland effluent for appropriate water uses. This study demonstrated the feasibility of pond system for subsequent management of wetland effluent during the winter season, however, more study is needed for field application.

수질배출부과금제도 개선 방안 연구 (The Effect of Industrial Waste Water Effluent Charge Reform)

  • 민동기
    • 자원ㆍ환경경제연구
    • /
    • 제18권4호
    • /
    • pp.767-785
    • /
    • 2009
  • 본 연구에서는 수질배출부과금제도의 부과체계를 분석하고 개선 방안을 연구하였다. 수질배출부과금제도는 환경오염 원인자에게 처리비용을 부담시켜 환경자원을 효율적으로 사용하도록 하는 경제적 유인 목적을 가지고 있으나 현행 수질배출부과금제도는 행정 규제적 성격이 강하다. 즉, 배출허용기준을 설정하여 이를 위반한 배출업소에 대하여 사업장 규모, 지역, 위반 횟수, 오염물질별 초과율을 고려한 누증적 부과계수를 적용하여 실제 환경오염 비용을 훨씬 초과하는 형벌적 성격의 부과금을 부과하고 있다. 그러나 과도한 부과금 부과로 배출부과금 징수율은 환경관련 부과금 중 가장 낮은 수준이다. 따라서 본 연구에서는 규제적 성격의 부과체계를 개편하여 경제적 유인제도로 수질배출부과금제도를 개편하는 부과체계 개편안을 연구하였으며 이에 따른 부과액 및 징수액 변화 효과를 추정하였다. 추정 결과를 보면 현행 부과금 부과액은 오염물질 처리단가의 약 4배 이상을 부과하고 있어 환경자원의 비효율적 배분을 초래하고 있음을 보여준다. 아울러 과도한 부과금 부과체계를 개선하는 경우에는 징수율도 제고되어 수질배출부과금제도의 기능을 회복할 수 있음을 보여준다.

  • PDF