• Title/Summary/Keyword: Efficiency tester

Search Result 108, Processing Time 0.024 seconds

Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater (산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정)

  • Park, Se-Jin;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.570-575
    • /
    • 2018
  • The various of raw wastewater inflows to the industrial wastewater treatment plants everyday. This makes it difficult to operate the coagulation and flocculation efficiently as a pretreatment process for the industrial wastewater treatment. Additionally, it causes loads on evaporation and membrane facilities which are the posttreatment and alternative processes. For this reason, this study sampled raw wastewater before and after the NaOH injection. An experiment was conducted to compare the coagulation characteristics according to the methods of coagulant injection (single injection, simultaneous injection, consecutive injection, and inverse injection) aiming at efficient treatment of industrial wastewater. The coagulation experiment was conducted using a jar tester. The TDS removal efficiency by the coagulant injection methods increased in the order of consecutive injection (2.8 %) < single injection (3.9 %) < simultaneous injection(8.1 %) < inverse injection(9.6 %); the TOC removal efficiency grew in the order of single injection (84.3 %) < inverse injection (86.2 %) < consecutive injection (88.6 %) < simultaneous injection (89.1 %); the turbidity removal efficiency grew from single injection (99.7 %) < consecutive injection (99.8 %) ${\fallingdotseq}$ inverse injection (99.8 %) < simultaneous injection (99.9 %). These results show that the simultaneous inorganic coagulant-polymer coagulant injection method was more efficient than the consecutive injection method (inorganic coagulant ${\rightarrow}$ polymer coagulant).

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Leading Angles of a Rear-Guider for a Room Air-Conditioner (리어가이더 선단각도에 따른 룸에어콘용 관류홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.35-43
    • /
    • 2013
  • Generally, the chassis of an indoor RAC is composed of a rear-guider and a stabilizer. The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of the chassis of an indoor RAC. The purpose of this paper is to select the optimum design factors through the aerodynamic performance of a cross-flow fan. The design factors are the leading angle of a rear-guider (${\theta}_1$), a stabilizer setup angle(${\theta}_2$), a rear-guider clearance(${\epsilon}_1$), and a stabilizer clearance(${\epsilon}_2$), respectively. As a result, the optimum design factors of an indoor RAC can be presented as a combination of ${\theta}_1=33^{\circ}$, ${\theta}_2=55^{\circ}$, ${\epsilon}_1=6{\sim}8mm$, and ${\epsilon}_2=7mm$ through the analysis of a static pressure coefficient and a static pressure efficiency.

A Indication Functional Inspection circuit development for Fluorescent ramp end of life (EOL) (형광램프 수명말기 표시기능 검측회로 개발)

  • Hong, Sa-Keun;Choi, Hong-Kyoo;Lee, Guen-Moo;Yoon, Cheol-Gu;Choi, Dae-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.7-11
    • /
    • 2008
  • The fluorescent lamp is one of a discharge lane that is used by electric discharge to transfer from electrical energy to light The fluorescent lamp needs a ballast stabilizer when turn it on because it has negative resistance. Characters of electric discharge and transformed characters of ballast stabilizer are connected closely. Therefore, bring out best design directive that consider economical efficiency and term of a application is very important for both characters matching. In this case, we will team to develop tester and functions for expression for recognizing the end of fluorescent lamp life to solve fire problem and losing efficiency of light when a fluorescent lamp goes the end of the expected its life span.

  • PDF

Comparing Flotation Efficiency of Algae-Containing Raw Water using PAC Coagulants (PAC 응집제 종류에 따른 조류가 포함된 상수원수의 부상분리효율 비교)

  • Jong-Won Park;Seong-Kee Min;Hye-Yeon Lee;Churl-Jong Yun;Chang-Han Lee
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.355-363
    • /
    • 2023
  • This study used a batch DAF (dissolved air flotation) jar tester to evaluate the algae removal efficiency of alum and PAC coagulants during coagulation, flocculation, and flotation. Optimal coagulant dosages were 0.06 ~ 0.15 mL/L (12.0 ~ 26.0 mg Al/L,17%), 0.08 ~ 0.20 mL/L (10.0 ~ 24.0 mg Al/L, 12%), 0.25 ~ 0.30 mL/L (25.0 ~ 30.0 mg Al/L, 10%) for PAC, and 3.0 ~ 5.0 mL/L (81.0 ~ 135.0 mg Al/L, 2.7%) for alum. Turbidity of treated water was 1.0 ~ 2.0 NTU in optimal coagulation, flocculation, and flotation conditions for the four coagulants types. The amount of coagulant injected tended to decrease with increasing Al content in the coagulant, as follows : 17% PAC < 12% PAC < 10% PAC < 2.7% alum. Turbidity removal efficiencies were in the order of 12% PAC (93.6%) > 10% PAC (92.7%) > 17% PAC (91.3%) > 2.7% Alum (88.1%).

The Experimental Comparison of Fault Detection Efficiency of Static Code Analysis Tools for Software RAMS (소프트웨어 RAMS를 위한 정적기법을 이용한 코드 결함 검출 효율성에 관한 실험적 비교)

  • Jang, Jeong-Hoon;Yun, Cha-Jung;Jang, Ju-Su;Lee, Won-Taek;Lee, Eun-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2493-2502
    • /
    • 2011
  • For Static analysis of software code, an experienced tester prefer detecting defects with using selective static technique. Many cases of static method have been reported such as coding rules, software metrics, defect data, etc. However, many of analysis case only present effectiveness of static analysis, not enough description for how the tester judged to classify code defects used in code analysis and removed them properly for ensure high quality. Occasionally, there are materials to show the effect of through some examples through some examples. But difficult to gain trust, because of not enough detail for application process. In this paper, introduced the static technique commonly used in railway and applied to the real development challenges. And the each of results were compared and analyzed. It is hard to generalize the results of this parer. But can be used and referenced as a case of study.

  • PDF

A Study on a MMORPG Battle Simulator with Input of Rules (룰 입력을 통한 MMORPG전투 시뮬레이터에 관한 연구)

  • Kim, Jung-Hyun;Kim, Kyung-Sik
    • Journal of Korea Game Society
    • /
    • v.7 no.3
    • /
    • pp.97-103
    • /
    • 2007
  • Battles between players and monsters are considered to be the core issues of RPG games, and they are something that effects the players the most when it comes to thinking whether that particular game is fun or not. Even though MMORPGs have enabled RPGs to get out of the repetitiveness into unlimited possibility of expandability and capability of modification of game plays, essential game play process remains still important - the basic battle between the player and the monsters. In this research, we made a simulator to simulate the process of the battles to estimate results of battles by pre-testing the battles with setting up the experience values of players and monsters using formulae needed for the battle systems at the beginning of game development. It can be utilized at a tester to find out a better configuration of monsters in the maps for better optimization of time and efficiency of the battles to satisfy the game planning.

  • PDF

Effects of Er:YAG Laser Irradiation on Removal of Subgingival Calculus. (Er:YAG laser 조사에 의한 치은연하치석 제거효과)

  • Cho, In-Gu;Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.315-324
    • /
    • 2002
  • The purpose of this in vitro study was to evaluate the efficiency of Er:YAG laser on calculus removal and the morphologic changes and hardness of the irradiated surface at different power settings. This experiment used human teeth which were extracted due to periodontal disease and had a band of calculus. Forty root slabs ($5{\times}5mm$) were made and divided into control group and irradiated groups. Experimental groups were as follows; Control group (root planing), Group1 (irradiated with laser at 30mJ), Group2 (irradiated with laser at 60mJ), Group3 (irradiated with laser at 100mJ). Twelve root slab embedded in resin block were used in each group. Er:YAG laser was applied under water irrigation with the tip held perpendicular to the root surface in contact mode. The treatment time was measured until the calculus was removed completely under naked eyes. The efficiency of calculus removal was evaluated by the time for removal. Morphological changes of laser irradiated site were observed under SEM and the surface hardness was measured using a VH tester. The results were as follows; 1. The efficiency of laser scaling was increased with increasing the energy level of irradiation(p<0.05). 2. The morphological changes such as carbonization, crater and scale-like defects in the irradiated root surface were frequently observed with increasing the energy level. 3. The surface hardness tended to increase at 60mJ and 100mJ irradiated groups than that of control group. From the results evaluting on the efficiency, morphological change and surface hardness, lower energy level was suggested for the clinical application of the Er:YAG laser in scaling.

A Study on the Properties of Photocatalytic Cement for Waste Gas Reduction (배기가스 제거용 광촉매시멘트의 특성에 관한 연구)

  • Lee, Won-Am;Yang, Jin;Ryu, Jae-Sang;Lee, Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.425-430
    • /
    • 2002
  • The needs of the times, a cement plays an important roll in the materials field. So, in this research we would like to study on the properties of Photocatalytic Cement for waste gas reduction. The fundamental phenomena of the Photocatalytic Cement were observed by the NOx Analyzer, Bonding strength, SEM, Flow and Surface hardness(Pencil tester). As a result of this study, the Photocatalytic Cement used Photocatalytic powder, admixture and other materials can obtain its physical properties, also photocatalytic efficiency. If we have added a various experiment, we could have to develop the Photocatalytic Cement.

  • PDF

A Study on The Filtration Characteristics of Magnetic Fibrous Polymeric Filter with Packing Density Profile as a New Oil Filter (윤활시스템용 오일필터로서 충전밀도 변화에 따른 자성폴리머 필터의 여과특성 연구)

  • 최기영;안병길;최웅수;권숙인;권오관
    • Tribology and Lubricants
    • /
    • v.11 no.2
    • /
    • pp.8-14
    • /
    • 1995
  • The filtration of the magnetic fibrous polymeric filter with packing density profile made of a self-bonded, nonwoven structure comprising a thermoplastic polymer and a magnetic substance was investigated using an oil filter tester, a particle quantifier and an image analyzer system. The magnetic fibrous polymeric filter showed excellent filtration efficiency compared with conventional paper filter. From the experimental results, It is deduced that the filtration mechanism of conventional paper filter is only the function of physical porosity by surface filteration. On the other hand, the newly magnetic fibrous polymeric filter is designed with a new concept in filtration mechanism. That is, it has a dual function of depth and magnetic filters by physical porosity and magnetic attraction. The newly magnetic fibrous polymeric filter has been shown to be a highly effective oil filter for lubrication systems.