• 제목/요약/키워드: Efficiency of Treatment

검색결과 5,226건 처리시간 0.036초

과실 채소중 잔류농약(유기인제)에 관한 연구 (Organophosphorus Insecticide Residues in Fruits and Vegetables)

  • 윤숙자
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

국내 정수장 고도정수처리 공정에서 공정별 처리효율 조사 (Investigation of Treatment Efficiency for Advanced Processes of Water Treatment Plants in Korea)

  • 문성민;최승일;손진식;윤제용
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.323-329
    • /
    • 2005
  • Advanced processes such as ozonation or activated carbon filtration (ACF) in water treatment plants have been used in Korea since 1994. At present, seventeen drinking water treatment plants are currently operating. This survey compares the treatment performance of advanced processes in eight plants which have comparable water quality data. The three parameters (DOC, $UV_{254}$, and $KMnO_4$ consumption) of water quality were selected as an indicator of treatment efficiency. The treatment efficiency of ozonation and ACF processes was found to vary with large deviations in each plant. Treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption by post ozonation ranged from 3 to 11%, 6 to 33%, and 12 to 28% respectively. On the other hand, for ACF, treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption ranged from 7 to 38%, 8 to 48%, and 16 to 66% respectively. These large deviations indicate the advanced processes of water treatment plants to be further optimized.

계절에 따른 농촌 지역 하수종말처리장의 처리 효율 변화 (Changes of Treatment Efficiency According to Seasonal Variation in Rural Area)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제17권3호
    • /
    • pp.311-319
    • /
    • 2015
  • 국토의 균형적인 개발과 수계 수질 보호를 목적으로 한국 정부는 농촌 지역 하수도 보급 사업을 진행하고 있다. 본 연구는 농촌 지역 하수도 보급 사업의 하나인 A 하수종말처리장의 연간 운전결과를 분석하였다. 농촌 지역 하수종말처리장 유입 하수 농도는 계절에 따라 변화하며, 여름철에 가장 낮은 것으로 나타났다. 계절 변화에 따른 생물반응조의 처리 효율은 유기물질에 비해 영양염류가 계절에 따라 처리 효율의 변화가 큰 것으로 나타났으며 겨울철에 가장 낮은 것으로 나타났다. 또한 영양염류는 체류시간과 F/M ratio에 대해 유기물보다 민감하게 반응한 결과를 보였다. 농촌 지역 하수종말처리장 공법 선정 시 계절에 따라 변화하는 유입 하수의 특성을 고려해야 한다. 또한 겨울철 영양염류의 안정적인 처리 효율을 위한 유지관리가 필요하다.

은 함유 폐수의 연속 순환 전해처리 시 유량변화가 회수 공정에 미치는 영향 (Effect of Flow Rate on the Continuous Cycling Electrolytic Treatment Process for Silver Ion Containing Wastewater)

  • 정원주;김동수
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.577-580
    • /
    • 2007
  • The influence of flow rate has been investigated on the treatment efficiency of continuous cycling electrolytic process employing artificial and actual photographic wastewater which containing silver ion. For artificial wastewater, the treatment efficiency of process was found to rise ca. three times when the flow rate of wastewater was increased from 3 mL/min to 15 mL/min. The process efficiency was doubled under the same condition regarding actual wastewater. The effect of flow rate on the treatment efficiency was observed to be altered according to the metal ionic form and solution composition. The coefficient of mass transfer was estimated using model equation, which verified that the raised treatment efficiency at higher flow rate was due to the increased mobility of ionic species.

섬유 형태에 따른 염색폐수 배출특성 연구 (Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification)

  • 이수형;박정민;박상정;정제호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.

활성슬러지공정과 고도처리공정에 따른 하수처리수의 처리효율과 유기물 특성 (Treatment Efficiency and Organic Matter Characterization of Wastewater through Activated Sludge Process and Advanced Wastewater Treatment Process)

  • 홍지혜;손진식
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.807-813
    • /
    • 2004
  • Wastewater was treated by two different treatment processes; activated sludge process and advanced wastewater treatment process (KNR process) using lab-scale experiment. Two treated wastewater showed good treatment efficiency of organic matter removal, up to 90% removal. Nitrogen and phosphorus were not effectively removed though activated sludge process, while KNR process showed good removal efficiency of nitrogen and phosphorus; 56% nitrogen removal and 95% phosphorus removal. KNR process showed better removal efficiency of organic matter, nitrogen, and phosphorus compared to activated sludge process. Organic matter characterization was tracked though measurement of UV scan, SUVA, and XAD fractionation. Treated wastewater showed higher SUVA value than wastewater influent, indicting less aromatic characteristic of organic matter. XAD fractionation showed hydrophilic fraction decreased though wastewater treatment, suggesting microbes preferentially digest hydrophilic and aliphatic molecules rather than hydrophobic and aromatic molecules of organic matter.

耳鳴의 形態와 治療效率에 對한 臨床的 分析 (A Clinical analysis on the Treatment efficiency of Tinnitus by Types of bianzheng(辨證))

  • 김경준
    • 한방안이비인후피부과학회지
    • /
    • 제12권2호
    • /
    • pp.182-188
    • /
    • 1999
  • Tinnitus is a symptom frequently encountered in the E.N.T. clinic and variously described as buzzing, ringing and thumping sound, etc., but the cause, pathogenesis, specific treatment remains to be established through close investigation. In fact, it is not easy to evaluate the treatment efficiency of tinnitus reasonably. However, in this study. we clinically investigated 47 patients who visited E.N.T. department of Kyung Won University Hospital from May. 1996 to May. 1999 and belonged to specific bianzheng(辨證) types of tinnitus classified by bianzheng(辨證), a kind of diagnostic method in order to estimate efficiency of the treatment and give aids to establishing more effective and recognizable treatment method. The result is as follows: 1) In bianzheng(辨證) types of tinnitus, Piweixuruo(脾胃虛弱) was most frequently found, in descending order, Shenjingkuisun(腎精虧損), Ganhuoshangra(肝火上擾), Tanhuoyongjie(痰火壅結). 2) In the treatment efficiency, the type of Piweixuruo(脾胃虛弱) showed the highest, in descending order, Ganhuoshangrao(肝火上擾), Tanhuoyongjie(痰火壅結) and Shenjingkuisun(腎精虧損). 3) The treatment efficiency is shown higher in patients with tinnitus included in other sysmptoms than those with a simple symptom of tinnitus. especially in case of tinnitus accompanied by vertigo, we could get much higher treatment efficiency more than we had expected.

  • PDF

Do customized orthodontic appliances and vibration devices provide more efficient treatment than conventional methods?

  • Aldrees, Abdullah M.
    • 대한치과교정학회지
    • /
    • 제46권3호
    • /
    • pp.180-185
    • /
    • 2016
  • The incorporation of technological advances in the field of clinical orthodontics to increase treatment efficiency has led to the development of customized appliances (Insignia$^{(R)}$), archwires (Suresmile$^{(R)}$), and the production of devices to enhance tooth movement (Acceledent$^{(R)}$). This review presents a comprehensive study of the literature concerning these products, and analyzes the available evidence of their efficiency. To date, one pilot study has evaluated the efficiency of the Insignia$^{(R)}$ system, three retrospective studies have assessed the efficiency of the Suresmile$^{(R)}$ system, and a few Acceledent$^{(R)}$ reports have described its effect on treatment time. Critical appraisal of the reviewed papers revealed that the efficiency of the Insignia$^{(R)}$ system cannot be confirmed based on the available evidence, while the use of Suresmile$^{(R)}$ can reduce overall treatment time in simple cases. The acceleration of tooth movement by Acceledent$^{(R)}$ devices has not yet been confirmed.

BCS-II 공법을 이용한 마을하수도 처리 효율 분석: 안동시를 대상으로 (Analysis of RCSTP Treatment Efficiency using BCS-II Process: Case Study of An-dong City)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제16권4호
    • /
    • pp.423-431
    • /
    • 2014
  • 상수원과 같은 수계 수질 보호 및 농촌 지역 개발을 위해 마을하수도 보급이 필요하다. 본 연구에서는 안동 지역 마을하수도(11개소) 유입하수 특성 및 마을하수도에 도입된 처리 공법의 결과를 분석하였다. 안동 지역 마을하수도 유입하수는 도시지역에 비해 고농도의 유기물과 영양염류를 함유하고 있는 것으로 분석되었다. 안동시 마을하수도 공법은 안정적인 처리효율을 보였지만, 영양염류의 경우 유기물에 비해 solid retention time(SRT)와 food to microorganisms (F/M) ratio에 민감한 것으로 나타났다. 또한 안동 지역 마을하수도 공법은 타 공법($A^2/O$, SBR, media)들과 비교하여 전반적으로 높은 처리 효율을 보였으며, 본 공법은 마을하수도에 효과적으로 적용 가능한 공법이라 판단된다.

Efficiency enhancement of the organic light-emitting diodes by oxygen plasma treatment of the ITO substrate

  • Hong, J.W.;Oh, D.H.;Kim, C.H.;Kim, G.Y.;Kim, T.W.
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.193-197
    • /
    • 2012
  • Oxygen plasma has been treated on the surface of indium-tin-oxide (ITO) to improve the efficiency of the organic light-emitting diodes (OLEDs) device. The plasma treatment was expected to inject the holes effectively due to the control of an ITO work-function and the reduction of surface roughness. To optimize the treatment condition, a surface resistance and morphology of the ITO surface were investigated. The effect on the electrical properties of the OLEDs was evaluated as a function of oxygen plasma powers (0, 200, 250, 300, and 450 W). The electrical properties of the devices were measured in a device structure of ITO/TPD/Alq3/BCP/LiF/Al. It was found the plasma treatment of the ITO surface affects on the efficiency of the device. The efficiency of the device was optimized at the plasma power of 250 W and decreased at higher power than 250 W. The maximum values of luminance, luminous power efficiency, and external quantum efficiency of the plasma treated devices increase by 1.4 times, 1.4 times, and 1.2 times, respectively, compared to those of the non-treated ones.