• Title/Summary/Keyword: Efficiency Standards

Search Result 995, Processing Time 0.025 seconds

산업현장의 소음.진동 원인분석 및 저감방안 연구 (Assessment of Can Factory working noise and its reduction)

  • 전형준;고준희;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.212-216
    • /
    • 2006
  • The purpose of this study is to obtain an effective enclosing method for noise reduction of press machine operating in a manufacturing company located in Korea. Noise level of the machine is about $90{\sim}105dB$ which is higher than legal standards by industrial safety and health law. This study has predicted the level of noise reduction according to a step by step prevention plan by considering the characteristics of the cause of noise, the permitted limit of noise levels, problems and economical efficiency attendant upon the noise prevention measures. The predicted level of noise at the plant in accordance with the first step is $71.5{\sim}89.5dB(A)$, and can satisfy the permitted limit of noise in a time period of the day. Based on these results, enclosing method adequate for the selected plant's noise characteristics were suggested.

  • PDF

대전력시험 전용 응용 프로그램 (Application Program Specialized for High Power Testing Station)

  • 오승렬;박지훈;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.150-152
    • /
    • 2008
  • It is necessary to improve the time efficiency in the high power testing station because tests are mainly performed by high-priced equipment. Minimizing a human error through building the database of relevant standards is possible to expect reliable tests. And also, application program that is properly customized for the certain laboratory's power system will help test engineer to easily analyze the phenomenon that is happened in short-circuit and load switching tests. This paper introduces the several functions of the application program that is developed in order to realize these requirements.

  • PDF

에너지 효율향상 의무화제도(EERS)의 동향 및 국내도입 필요성 검토 (An Introduction of The Energy Efficiency Resource Standards(EERS) and Examination of Necessity)

  • 송길선;이우남;김진호;박종배;신중린;김형중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.246-248
    • /
    • 2007
  • 에너지안보와 기후변화에의 대응을 위한 에너지 효율향상은 다른 에너지대안에 비하여 가장 비용 효과적으로 에너지 절감을 이끌어 낼 수 있는 시책으로 에너지원의 새로운 개발과도 동일한 의미를 부여할 수 있다. 다양한 에너지 효율향상 시책 중 에너지효율향상 의무화제도(EERS)는 전력 및 천연가스를 보다 효율적으로 생산/전달/이용하기 위한 단순하면서도 시장경제에 기반한 메커니즘으로 정부가 설정한 에너지효율 개선 목표를 지역 내 전력/가스 공급업체들에게 배분하여 의무적으로 목표를 달성토록 요구하고, 미달성시 범칙금(penalty)를 부과하거나 크레딧(credit)을 통해 거래시장에서 미달목표량에 해당하는 인증서를 확보하도록 하여 국가 전체적인 에너지 효율을 개선시키는 제도이다. 본 논문에서는 현재 시행되고 있는 EERS의 개요 및 다양한 사례들의 검토를 통해 시사점을 도출하여 국내도입 필요성에 대하여 언급하고자 한다.

  • PDF

A New Single-Stage PFC AC/DC Converter with Low Link-Capacitor Voltage

  • Lee, Byoung-Hee;Kim, Chong-Eun;Park, Ki-Bum;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.328-335
    • /
    • 2007
  • A conventional Single-Stage Power-Factor-Correction (PFC) AC/DC converter has a link capacitor voltage problem under high line input and low load conditions. In this paper, this problem is analyzed by using the voltage conversion ratio of the DC/DC conversion cell. By applying this analysis, a new Single-Stage PFC AC/DC converter with a boost PFC cell integrated with a Voltage-Doubler Rectified Asymmetrical Half-Bridge (VDRAHB) is proposed. The proposed converter features good power factor correction, low current harmonic distortions, tight output regulations and low voltage of the link capacitor. An 85W prototype was implemented to show that it meets harmonic requirements and standards satisfactorily with near unity power factor and high efficiency over universal input.

변전소 구조물의 에너지파일 시스템 적용성 연구 (A Sutdy on the Apllicability of the Energy Pile System on Substation)

  • 이대수;오기대;이강렬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.198-198
    • /
    • 2011
  • Cooling and Heating system using Geothermal energy in the country has shown rapid development in the research and business field during about 10 years. However, like other renewable energy sources, high initial construction cost is acting as an obstacle to apply widely. Therefore Energy pile system(Heat Exchanger inserted inside the structure pile) that can save about 25 % initial construction cost has been studied in European countries and recently being studied in our country. Therefore, KPECO(Korea Electric Power Corporation) is also studying energy pile system to improve cooling & heating system in substation that install about 200 pile. KPECO is aimed to make energy pile design, construction and maintenance standards because substation has good applicability. In this study, we studied to make new grout material and design program to make optimized design & counstruction method of energy pile system. And planing to peform field test for energy pile system in a 154 kV substation to obtain long-term behavior and efficiency of the system.

  • PDF

Step 가변형 MPPT 제어기법과 DVR을 적용한 계통연계형 태양광 발전 시스템 (Grid-Connected Photovoltaic System Applying the Step Variable MPPT Control and DVR)

  • 이용식;정성원;김재현
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.42-49
    • /
    • 2012
  • Grid-connected photovoltaic generator system requires high performance PCS(Power Conditioning System) according to the standard of 'Distributed Generation Grid-Connected Technology Standards'. This paper presents the MPPT control method which improves output efficiency through fast tracking to the maximum power point of PV and a reduced self-excited vibration. Secondly, in this paper DVR function was applied to PCS to compensate the voltage sag frequently happening for a power system. The proposed PCS control is analyzed and compared to conventional PCS operating characteristic, the various insolation and loads, and voltage sag condition through PSIM tool. It proves the utility.

OFSA: Optimum Frame-Slotted Aloha for RFID Tag Collision Arbitration

  • Lee, Dong-Hwan;Choi, Ji-Hoon;Lee, Won-Jun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권11호
    • /
    • pp.1929-1945
    • /
    • 2011
  • RFID technologies have attracted a lot of attention in recent years because of their cost/time-effectiveness in large-scale logistics, supply chain management (SCM) and other various potential applications. One of the most important issues of the RFID-based systems is how quickly tags can be identified. Tag collision arbitration plays a more critical role in determining the system performance especially for passive tag-based ones where tag collisions are dealt with rather than prevented. We present a novel tag collision arbitration protocol called Optimum Frame-Slotted Aloha (OFSA). The protocol has been designed to achieve time-optimal efficiency in tag identification through an analytic study of tag identification delay and tag number estimation. Results from our analysis and extensive simulations demonstrate that OFSA outperforms other collision arbitration protocols. Also, unlike most prior anti-collision protocols, it does not require any modification to the current standards and architectures facilitating the rollout of RFID systems.

노인요양시설의 웰니스 IT서비스 활용에 관한 연구 (A Study on the Utilization of Wellness IT Service in Nursing Care Center for the Elderly)

  • 박영석;진성광;김석;최정일
    • 한국IT서비스학회지
    • /
    • 제19권5호
    • /
    • pp.93-106
    • /
    • 2020
  • This study attempts to present specific technical measures and case models to meet the needs of caregivers and maximize the effectiveness of senior care facilities by utilizing Wellness IT Service. IT services for supporting elderly care need to go beyond productivity and efficiency and now require the new choice and standards to satisfy the Wellness concept of well-being and happiness. Therefore, this study explores to develop the existing human-based service into the Wellness IT Service by utilizing IT based Wellness in the elderly care facility and thereby to improve the quality of elderly care service. Therefore, this study analyzes the relevant research background and the various feasibility of technical applications of Wellness IT service, and review the new value creation in the elderly care facilities. Lastly this study provides a new foundation for Wellness architecture and a service model for using Wellness IT infrastructure of the elderly care facilities.

주요 전기 기기에 대한 각국의 에너지효율기준 비교 분석 (Analysis and Comparison of International Energy Efficiency Standards for Principal Electric Equipments)

  • 원종률;김정훈;변천석;서백호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.405-407
    • /
    • 2005
  • 고유가 시대를 맞아 에너지효율이 높은 고효율기기에 대한 관심이 높아지고 있다. 이에 따라 본 논문에서는 주요 가전기기에 대한 세계 주요 각 국의 에너지 효율기준을 조사하여 비교하고자 한다. 미국, 유럽, 호주, 캐나다, 일본, 한국의 기기별 에너지 효율기준을, 우선 국내에서 가장 많이 사용되고 있는 형광등 및 안정기, 에어컨, 냉장고/냉동고에 대하여 우선 작성하였다. 이 외에도 세탁기, 식기세척기, 전기오븐, 변압기, 전기온수기 통의 기기에 대해서도 조사하였으나 지면상 생략하였다.

  • PDF

기계를 위한 비디오 부호화 표준화 동향 (Standardization Trends in Video Coding for Machines)

  • 권형진;정세윤;최진수;이태진;서정일
    • 전자통신동향분석
    • /
    • 제35권5호
    • /
    • pp.102-111
    • /
    • 2020
  • An increase in high-quality video service continually leads to the standardization of high-performance video codecs such as the versatile video coding standard. Although such codecs have improved coding efficiency in terms of high fidelity, a tremendous increase in the amount of video data is required for more efficient compression, especially for efficiently recognizing and analyzing the target within the millions of objects/events captured every day, such as those by surveillance systems. Therefore, newly established MPEG standardization efforts have studied the new generation of video compression standards for machine vision-oriented video. This paper presents the standardization trends in video coding for machines and discusses further directions for improvement.