• 제목/요약/키워드: Efficiency Standard

검색결과 2,816건 처리시간 0.027초

A Review of the Methods for Improving the Efficiency of Drive Motors to Meet IE4 Efficiency Standards

  • Dorrell, David G.
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.842-851
    • /
    • 2014
  • High efficiency standards are slowly being introduced with IE3 efficiency levels shortly becoming compulsory in many countries; IE4 efficiency levels being developed for future implementation. In this paper a review is carried out of the IE 60034-30 standard which covers standard line-start induction motors. Some design techniques that can be used to increase efficiency in order to meet the IE4 standards are discussed. This standard is now being replaced by the IE60034-30-1 standard which extends to other line start motors and also IE 60034-30-2 is being introduced to cover variable speed drives in order to address developing technology. The conclusion is that IE4 standards are obtainable but careful design is needed to reach this. Examples from the literature are given.

Membership Wholesale Club에서의 RRP 적재패턴 및 블록패턴 표준규격에 관한 연구 (RRP Loading Patterns and Standard Dimensions for Block Pattern in Membership Wholesale Clubs)

  • 정성태;한규철
    • 유통과학연구
    • /
    • 제13권7호
    • /
    • pp.41-51
    • /
    • 2015
  • Purpose - This study analyzes loading efficiency by loading pattern for package standardization and reduction of logistics costs, along with the creation of revenue for the revenue review panel (RRP) of Membership Wholesale Clubs (MWC). The study aims to identify standard dimensions that can help improve the compatibility of the pallets related to display patterns preferred by the MWC and thereby explore ways to enhance logistics efficiency between manufacturers and retailers through standardization. Research design, data, and methodology - The study investigates and analyzes the current status based on actual case examples, i.e., manufacturer A and Korea's MWC (A company, B company, and C company), and thus devises improvement measures. To achieve this, the case of manufacturer A delivering to MWC was examined, and the actual pallet display patterns for each MWC were investigated by visiting each distribution site. In this study, TOPS (Total Optimization Packaging Software, USA) was used as the tool for pallet loading efficiency simulations the maximum allowable dimension was set to 0.0mm to prevent the pallet from falling outside the parameters, and the loading efficiency was analyzed with the pallet area. In other words, the study focused on dimensions (length x width x height) according to the research purpose and thereby deduced results. Results - The analysis of pallet loading patterns showed that the most preferred loading patterns for loading efficiency according to product specification, such as pinwheel, brick, and block patterns, were used in the case of the general distribution products, but the products were configured with block patterns in most cases when delivered to MWCs. The loading efficiency by loading pattern was analyzed with respect to 104 nationally listed standard dimensions. Meanwhile, No.51 (330 × 220mm) of KS T 1002 (1,100 × 1,100mm) was found to be the dimension that could bring about an improved loading efficiency, over 90.0% simultaneously in both the T-11 and T-12 pallet systems in a loading pattern configuration with the block pattern only, and the loading efficiency simulation results also confirmed this as the standard dimension that can be commonly applied to both the T-11 pallet (90.0%) and the T-12 pallet (90.7%) systems. Conclusions - The loading efficiency simulation results by loading pattern were analyzed: For the T-11 pallet system, 17 standard dimension sizes displayed the loading efficiency of 90.0% or more as block patterns, and the loading capacity was an average of 99.0%. For the T-12 pallet system, 35 standard dimension sizes displayed the loading efficiency of more than 90% as block patterns (the average loading efficiency of 98.6%). Accordingly, this study proposes that the standard dimensions of 17 sizes with the average loading efficiency of 99.0% should be applied in the use of the T-11 pallet system, and those of 35 sizes with the average loading efficiency of 98.6% should be reviewed and applied in the use of the T-12 pallet system.

팔레트 적재효율을 고려한 농산물 포장상자 통합규격에 관한 연구 (A Study on Unified Packing Standard for Agricultural Products Based on Pallet Stacking Efficiency)

  • 서교;이정재;서병륜
    • 한국농공학회논문집
    • /
    • 제47권1호
    • /
    • pp.13-22
    • /
    • 2005
  • Despite the variety in sizes and shapes of agricultural products, the unified standardization of packing has been a long time necessity. In this study the stacking efficiency of packing standards for each box using packing Monte Carlo simulation based on the standard pallet is evaluated. As a result of simulation the unified packing standard for agricultural products is suggested by 550$\times$366 mm. With this study it is expected that the unification of the standards can help to increase the utilization of reusable packages and to improve efficiency of agricultural logistics.

농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구 (A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses)

  • 박미란;류연수;최정만;서혜원
    • 한국농촌건축학회논문집
    • /
    • 제19권2호
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

전자사진 기술을 사용하는 이미징 장치의 에너지 효율 기준 연구 (Energy efficiency standard for imaging equipments using electrophotograph printing)

  • 박준영;윤원식
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2433-2442
    • /
    • 2014
  • 본 논문에서는 전자사진 기술을 이용하는 프린터, 복사기, 팩시밀리, 복합기 등과 같은 이미징 장치의 효율등급기준에 대한 연구를 수행하였다. 대기전력을 관리하고 있는 현 제도의 문제점을 파악하고 효율관리 필요성을 제안하였으며, 이를 위한 효율 기준을 국내 대기전력저감 프로그램에 등록된 실증 데이터를 기반으로 개발하였다. 효율부여지표를 찾기 위해 상관분석(Correlation Analysis)을 실시하였으며, 인쇄 속도가 가장 큰 상관계수(Correlation Coefficient)를 가짐을 확인하였다. 이를 적용한 복합기, 프린터에 대한 1~5 등급의 효율등급 기준과 에너지 프론티어 기준을 도출하였으며, 정책반영 시 연간 약 650 억 원의 에너지 비용을 절감할 것으로 기대한다.

TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석 (Analysis of TV Standby Power for Development of Energy Efficiency Standard)

  • 김익표;노경수
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.

Performance Analysis of Future Video Coding (FVC) Standard Technology

  • Choi, Young-Ju;Kim, Ji-Hae;Lee, Jong-Hyeok;Kim, Byung-Gyu
    • Journal of Multimedia Information System
    • /
    • 제4권2호
    • /
    • pp.73-78
    • /
    • 2017
  • The Future Video Coding (FVC) is a new state of the art video compression standard that is going to standardize, as the next generation of High Efficiency Video Coding (HEVC) standard. The FVC standard applies newly designed block structure, which is called quadtree plus binary tree (QTBT) to improve the coding efficiency. Also, intra and inter prediction parts were changed to improve the coding performance when comparing to the previous coding standard such as HEVC and H.264/AVC. Experimental results shows that we are able to achieve the average BD-rate reduction of 25.46%, 38.00% and 35.78% for Y, U and V, respectively. In terms of complexity, the FVC takes about 14 times longer than the consumed time of HEVC encoder.

유한요소 해석을 이용한 3상 유도전동기의 효율 불확도 평가 (Evaluation of Efficiency Uncertainty for Three-phase Induction Motor using Finite Element Analysis)

  • 이호현;박한석;전희득;우경일
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.163-168
    • /
    • 2017
  • This paper presented an evaluation method for the efficiency uncertainty of a three-phase induction motor using finite element analysis. The motor efficiency in the finite element analysis is calculated by the loss separation method as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element analysis and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the finite element analysis is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element analysis is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

인버터 구동 3상 유도전동기의 효율 불확도 평가 (Evaluation of the Efficiency Uncertainty for an Inverter-fed Three-Phase Induction Motor)

  • 이호현;박한석;전희득;김대경;우경일
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.724-729
    • /
    • 2018
  • This paper presented an evaluation method for the efficiency uncertainty of an inverter-fed three-phase induction motor using FEM. The motor efficiency in the FEM is calculated by the IEC 60034-2-3 as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element method and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the FEM is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element method is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

Status of High-efficiency Motor Technology and MEPS

  • Jang, Kibong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.803-808
    • /
    • 2017
  • Minimum Energy Performance Standard(MEPS) has been adapted in Korea since 2008. The efficiency standard of variable speed motors is scheduled for publication shortly. In this paper, author reviews the technical trends associated with a high efficient electric motors by reference to research papers, and reviews the research direction to prepare for IE5. This paper provides an overview of high efficiency motors. Various applications have been covered.