• Title/Summary/Keyword: Effective size

Search Result 4,770, Processing Time 0.03 seconds

Ischial Pressure Sore Reconstruction Using Inferior Gluteal Artery Perforator Flap (아래볼기동맥 관통가지피판을 이용한 궁둥 욕창의 치료)

  • Kim, Young Seok;Kang, Jong Wha;Lee, Won Jai;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.209-216
    • /
    • 2007
  • Purpose: The ischial area is by far the most common site of pressure sores found in wheel chair bound paraplegic patients, because greatest pressure is exerted from the body on this area in a sitting position. Even after a series of successful pressure sore treatments, the site is very prone to relapse by the simplest ordinary tasks of everyday life. Therefore, it is crucial to preserve the main pedicle during primary surgery. Various surgical procedures employed to treat pressure sores such as myocutaneous flap and perforator flap have been introduced. After introduction of ischial sore treatment using the inferior gluteal artery perforator (IGAP) has been made, the authors experienced favorable clinical results of patients who have undergone IGAP flap procedure in a three year time period. Methods: A total of 17 patients received IGAP flap surgery in our hospital from January 2003 to May 2006, among which 14 of them being males and 3 females. Surgery was performed on the same site again in 6(35%) patients who had originally relapsed after receiving the conventional method of pressure sore surgery. Patients' average age was 49.4(27-71) years old. Most of the patients were paraplegic(11 cases, 65%) and others were either quadriplegic(4 cases, 23%) or ambulatory(2 cases, 12%). Based on hospital records and clinical photographs, we have attempted to assess the feasibility and practicability of the IGAP flap procedure through comparative analysis of several parameters: size of defective area, treatment modalities, occurrence of relapses, complications, and postoperative treatments. Results: The average follow-up duration of 17 subjects was 25.4 months(5-42 months). All flaps survived without any necrosis. Six cases were relapsed cases from conventional surgical procedures. All of them healed well during our follow-up study. Postoperative complications such as wound dehiscence and fistula developed in some subjects, but all were well healed through secondary treatment. A total of 2 cases relapsed after surgery. Conclusion: The inferior gluteal artery perforator flap is an effective method that can be primarily applied in replacement to the conventional ischial pressure sore reconstructive surgery owing to its many advantages: ability to preserve peripheral muscle tissue, numerous possible flap designs, relatively good durability, and the low donor site morbidity rate.

Vaginal Reconstruction with Modified Singapore Flap in MRK Syndrome Patients (MRK증후군 환자에서 변형 Singapore피판술을 이용한 질 재건)

  • Kim, Do-Hoon;Pyon, Jai-Kyong;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung;Lim, So-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.616-620
    • /
    • 2011
  • Purpose: Mayer-Rokitansky-Kuster syndrome (MRK) is second common cause of primary amenorrhea. It is a syndrome of vaginal aplasia and Mullerian duct anomaly. Vaginal aplasia varies from agenesis of whole vagina to aplasia of upper 2/3. For reconstructing vagina, various methods are introduced. Gracilis myocutaneous flap was the first attempt in that the flap is used in vaginal reconstruction. Various flap-based vaginal reconstruction methods have been introduced. Modified Singapore flap (pedicled neurovascular pudendal thigh fasciocutaneous flap) is one of those methods that used posterior labial artery as pedicle, and pudendal nerve branch as sensory root. As its donor lies on inguinal crease that is easily hidden and there are benefits on sexual intercourse by early sensory recovery, authors think that modified Singapore flap is effective for young MRK syndrome patients. Methods: Eight patients underwent surgery between 2008 and 2010. The flap was designed on both groin area with external pudendal artery branch as a pedicle. All flaps were fixated in pelvic cavity with absorbable suture, and additional compression on neovaginal wall was supplied by polyvinyl alcohol sponge ($Merocel^{(R)}$). Results: All patients were successfully reconstructed without flap related complications such as congestion or partial flap loss. The average size of the flap (each side) was 69.34 $cm^2$. Polyvinyl alcohol sponge ($Merocel^{(R)}$) was inserted into neovagina for 5 days on every patient. One case of rectal laceration was occurred while making pelvic pocket by OBGY team. Other complications such as lumen narrowing, wound contracture or vaginal prolapsed were not reported during 8 months of follow up. Conclusion: Modified Singapore flap is a sensate fasciocutaneous flap that is thinner than other myocutaneous flap such as VRAM, and more durable over skin graft. Therefore this is a good choice for vaginal reconstruction in MRK syndrome. And known complications of Modified Singapore flap could be reduced with careful procedure and mild compression techniques.

Experimental Assessment of Hemostatic Agents: Comparison with New Developed Chitosan-Based Material (신개발 키토산 제재의 지혈 효과에 대한 비교)

  • Cho, Young-Kyoo;Lee, Sang-Yun;Kim, Tae-Jung;Lim, Hyun-Ju;Oh, Eun-Jung;Lee, Soo-Bok;Choi, Kang-Young;Yang, Jung-Dug;Cho, Byung-Chae;Chung, Ho-Yun
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.369-375
    • /
    • 2011
  • Purpose: Many hemostatic agents and dressings have been tested with variable degree of success. Chitosan has a positive charge, it attracts red blood cells, which have a negative charge. Our goal is to test the efficacy of new developed chitosan-based hemostatic materials in providing durable hemostasis in a high-flow arterial wound model. Methods: We compared each group with SD rats motality tests and in vitro blood compatibility test by blood clotting index (BCI). We devided the SD rats into 6 groups (N =15) by type of hemostatic agents. A: 100% nonwoven chitosan (degree of the deacetylation: 90%). B: 50% N-acetylation on nonwoven of chitosan gel (degree of the deacetylation: 50%). C: 60% N-acetylation on nonwoven of chitosan ge (degree of the deacetylation: 40%)l. D: Cutanplast$^{(R)}$. E: HemCon$^{(R)}$ F: Gauze. In vivo test, a proximal arterial injury was created in unilateral femoral arteries of 90 anesthetized SD rats. Each materials was made same size and thickness then applied to the injury site for 3 minutes. In vitro test, we compared each group with BCI in human blood. Results: In vivo test, group A showed lower motality rate of 46% than any other groups, Group B and C showed lower motality rate of 60% than group D and E's motality rate of 66%. In vitro test, BCI of group A ($30.6{\pm}1.2$) and B ($29.3{\pm}1.0$) were showed nearly about group D ($29.1{\pm}1.8$) and E ($27.4{\pm}1.6$). Group C ($37.1{\pm}2.0$) showed higher BCI than group A and B, it means group C decreased blood clotting. Conclusion: In conclusion, this study suggests a newly developed chitosan-based hemostatic materials induced durable hemostasis and increased blood clotting, and are considered as effective biologic hemostatic agents.

Microsurgical Training using Preserved Saphenous Vein (혈관문합 연습을 위한 보존된 복재정맥의 활용)

  • Song, Jennifer K.;Hwang, So-Min;Lim, Kwang-Ryeol;Jung, Yong-Hui
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.391-395
    • /
    • 2010
  • Purpose: Given that the critical nature of the microvascular anastomosis to what is often a long and difficult reconstructive operation, trainees need to have a high level of microsurgical competence before being allowed to perform microsurgery on patients. Some artificial substitutes and dead or live animal models have been used to improve manual dexterity under the operating microscope. Yet, most surgeons are not equipped with such models, so search for easy available and appropriate microsurgical practice model have been an issue. Umbilical artery, placental vessels and gastroepiploic arteries have been previously suggested as a microsurgical training model, which involves other surgical departments. The purpose of this article is to introduce that saphenous vein specimen obtained from varicose vein surgery is useful and has many advantages as training model for the practice of microvascular anastomosis. Methods: The conventional technique using perforation/inversion method with a metallic stripper is widely performed for varicose vein patients. The stripper is inserted through disconnected safeno-femoral junction and retrieved at the knee or the medial side of ankle. The length of saphenous vein specimens removed is about that of one's leg and inversed from inside out. Obtained saphenous vein specimens are re-inversed and cleansed with normal saline, to be readily available for microsurgical practice. Preserved in a squeezed wet saline gauze and refrigerated, frozen or glycerated specimens were investigated into their comparative quality for microsurgical practice. Results: Varicose vein surgery remains one of the common operations performed in the field of plastic surgery. Convenient informed consent regarding the vessel donation can be easily signed. The diameter of the obtained saphenous vein is as variable as 1.5 to 6 mm, which is already stripped, and is in sufficient length corresponding to that of patient's leg. Vessels specimens were available for microsurgical practice within 1 week period when preserved with squeezed wet saline gauze, and the preservation period could be extended monthly by freezing it. Conclusion: Saphenous vein obtained from varicose vein patients provide with variable size of vessel lumen with sufficient length. The practice can be cost effective and does not require microsurgical laboratory. Additionally there is no need of involving other surgical departments in acquiring vessel specimens. Furthermore, simple preservation method of refrigerating for a week or freezing with squeezed wet saline gauze for a month period, allow the saphenous vein obtained after varicose vein surgery as an excellent model for the microsurgical practice.

Experiment for Reduction Effectiveness of Pollutants with the Improvement of Infiltration Ability in Vegetation Filter Strip (식생여과대내 침투능력 향상에 따른 오염물질 저감효과에 대한 실험)

  • Lee, Young-A;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.183-190
    • /
    • 2007
  • Soil layer in vegetation filter strip is one of the very important factor for reduction of non-point pollutants by physical, chemical and biological reactions of it through infiltration process. This study was carried out to prepare more effective vegetation filter strip through modification of soil layer for river water quality improvement. Therefore, the main aims of this study are to compare and evaluate normal (straighten type) and modified (step type) vegetation filter strip, which make artificially change the soil layer to improve infiltration ability, through bench scale experiments. In the results of this study, vegetation filter strip of step type is much more highly reduction effectiveness of pollutants in surface flow compared with normal vegetation filter strip. In case of below effluent, however, it appeared that the vegetation filter strip modified soil layer showed lower reduction effectiveness of pollutants than the general vegetation filter strip. This result was judged because effluent through the vegetation filter strip of step type passed bigger size of aggregate or sand than the vegetation filter strip of straighten type. If we compare it as a definition of pollutant load to estimate total amount of reduced pollutants by vegetation filter strip, reduced pollutants load by step type showed higher than those by straighten type because below effluent amount relied on total effluent amount was higher at step type (4%) than at straighten type (2%). In conclusion, the vegetation filter strip of step type to improve infiltration effect is much more reduction effectiveness of pollutants than vegetation filter strip of straighten type.

Clinical outcome of proton therapy for patients with chordomas

  • Youn, Sang Hee;Cho, Kwan Ho;Kim, Joo-Young;Ha, Boram;Lim, Young Kyung;Jeong, Jong Hwi;Lee, Sang Hyun;Yoo, Heon;Gwak, Ho-Shin;Shin, Sang Hoon;Hong, Eun Kyung;Kim, Han Kyu;Hong, Je Beom
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.182-191
    • /
    • 2018
  • Purpose: To investigate the clinical outcome of proton therapy (PT) in patients with chordoma. Materials and Methods: Fifty-eight patients with chordoma treated with PT between June 2007 and December 2015 at the National Cancer Center, Korea, were retrospectively analyzed. The median total dose was 69.6 cobalt gray equivalent (CGE; range, 64.8 to 79.2 CGE). Local progression-free survival (LPFS), distant metastasis-free survival (DMFS), overall survival (OS), and disease-specific survival (DSS) rates were calculated by the Kaplan-Meier method. Results: With the median follow-up of 42.8 months (range, 4 to 174 months), the 5-year LPFS, DMFS, OS, and DSS rates were 87.9%, 86.7%, 88.3%, and 92.9%, respectively. The tumor location was associated with the patterns of failure: the LPFS rates were lower for cervical tumors (57.1%) than for non-cervical tumors (93.1%) (p = 0.02), and the DMFS rates were lower for sacral tumors (53.5%) than for non-sacral tumors (100%) (p = 0.001). The total dose was associated with both the LPFS rate and DMFS rate. The initial tumor size was associated with the DMFS rate, but was not associated with the LPFS rate. Three patients had grade 3 late toxicity with none ≥grade 4. Conclusion: PT is an effective and safe treatment in patients with chordomas. The tumor location was associated with the patterns of failure: local failure was common in cervical tumors, and distant failure was common in sacral tumors. Further refinement of PT, such as the utilization of intensity modulated PT for cervical tumors, is warranted to improve the outcome.

Effect of Kami-kanghwalsan (KKHS) on Atopic Dermatitis-like Skin Lesions Induced in NC/Nga Mouse by Mite Antigen Stimulation (가미강활산(加味羌活散)이 집먼지 진드기 추출물로 유도된 NC/Nga mouse의 아토피 피부염에 미치는 영향)

  • Kim, Yun-Hee;Han, Jae-Kyung;Kim, Yun-Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.69-93
    • /
    • 2008
  • Objectives The purpose of this study is to investigate the effect of KKHS on atopic dermatitis in an in-vivo experiment using an NC/Nga atopic dermatitis mouse, which has histological and clinical similarities to this condition in humans. Methods To investigate the effect of KKHS on atopic dermatitis (AD), we evaluated atopic dermatitis-like skin lesions by clinical skin index and analyzed immunological parameters in peripheral blood mononuclear cells(PBMCs), splenocytes, draining lymph node(DLN) and performed skin histology in ears and dorsal skin of atopic dermatitis of NC/Nga mouse in vivo. Results In vivo, clinical skin severity score was significantly lower in the KKHS group than in the control group. IgE, IL-6, TNF-${\alpha}$, IgM, IgG2a and IgG2b levels in serum decreased remarkably in the KKHS group than in the control group, and the level of IFN-${\gamma}$ production which is secreted from Th1 cell was increased by KKHS. After this experiment we analyzed immunological cells ($CD3^+$, $CD19^+$, $CD4^+$, $CD8^+$, $CD3^+CD69^+$, $CD4^+CD25^+$ and $CD49b^+$) by flow cytometry. It results that the total absolute number of $CD3^+$, $CD19^+$, $CD4^+$ and $CD8^+$ cells were recovered as much as normal state, and the level of $CD3^+CD69^+$ in isolated DLN and PBMCs were significantly decreased, and total absolute number of $Gr-1^+$, $CD11b^+$ and $CD3^+$ in dorsal skin of NC/Nga mouse were decreased by KKHS. We analyzed ear, DLN, and neck-back skin after biopsy and dyeing by hematoxyline/eosin(H&E), toluidine staining (mast cells marker). KKHS were very effective to the histological symptoms which are in dermal and epidermal thickening, hyperkeratosis and inflammatory cell infiltration. Ear thickness was significantly decreased compared with the control group and the size of inflammatory lymphocytes cells (ILC) and plasma cells (PC) in DLN were also decreased. Conclusions KKHS on atopic dermatitis in an in-vivo experiment using an NC/Nga atopic dermatitis mouse was very effectiveness to the atopy dermatitis treatment.

  • PDF

Transmission Dose Estimation Algorithm for Irregularly Shaped Radiation Field (부정형 방사선 조사면에 대한 투과선량 보정 알고리즘)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Wu Hong Gyun;Lee Hyoung Koo;Shin Kyo Chul;Kim Siyong;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.274-282
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, the algorithm for estimating the transmission dose for open radiation fields was modified for application to partially blocked radiation fields. Materials and Methods : The beam data was measured with a flat solid phantom with various blocked fields. A new correction algorithm for partially blocked radiation field was developed from the measured data. This algorithm was tested in some settings simulating clinical treatment with an irregular field shape. Results : The correction algorithm for the beam block could accurately reflect the effect of the beam block, with an error within ${\pm}1.0\%$, with both square fields and irregularly shaped fields. Conclusion : This algorithm can accurately estimate the transmission dose in most radiation treatment settings, including irregularly shaped field.

Supplementation of the Indoor Location Tracking Techniques Based-on Load-Cells Mechanism (로드셀 기반의 실내 위치추적 보완 기법)

  • YI, Nam-Su;Moon, Seung-Jin
    • Journal of Internet Computing and Services
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current indoor intrusion detection and location tracking methods have the weakness in seamless operations in tracking the objective because the object must possess a communicating device and the limitation of the single cell size (approximate $100cm{\times}100cm$) exits. Also, the utilization of CCTV technologies show the shortcomings in tracking when the object disappear the area where the CCTV is not installed or illumination is not enough for capturing the scene (e.g. where the context-awarded system is not installed or low illumination presents). Therefore, in this paper we present an improved in-door tracking system based on sensor networks. Such system is built on a simulated scenario and enables us to detect and extend the area of surveillance as well as actively responding the emergency situation. Through simulated studies, we have demonstrated that the proposed system is capable of supplementing the shortcomings of signal cutting, and of estimating the location of the moving object. We expect the study will improve the better analysis of the intruder behavior, the more effective prevention and flexible response to various emergency situations.

LiDAR Chip for Automated Geo-referencing of High-Resolution Satellite Imagery (라이다 칩을 이용한 고해상도 위성영상의 자동좌표등록)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.319-326
    • /
    • 2014
  • The accurate geo-referencing processes that apply ground control points is prerequisite for effective end use of HRSI (High-resolution satellite imagery). Since the conventional control point acquisition by human operator takes long time, demands for the automated matching to existing reference data has been increasing its popularity. Among many options of reference data, the airborne LiDAR (Light Detection And Ranging) data shows high potential due to its high spatial resolution and vertical accuracy. Additionally, it is in the form of 3-dimensional point cloud free from the relief displacement. Recently, a new matching method between LiDAR data and HRSI was proposed that is based on the image projection of whole LiDAR data into HRSI domain, however, importing and processing the large amount of LiDAR data considered as time-consuming. Therefore, we wmotivated to ere propose a local LiDAR chip generation for the HRSI geo-referencing. In the procedure, a LiDAR point cloud was rasterized into an ortho image with the digital elevation model. After then, we selected local areas, which of containing meaningful amount of edge information to create LiDAR chips of small data size. We tested the LiDAR chips for fully-automated geo-referencing with Kompsat-2 and Kompsat-3 data. Finally, the experimental results showed one-pixel level of mean accuracy.