• 제목/요약/키워드: Effective Thickness

검색결과 1,955건 처리시간 0.024초

입구경계층 두께와 경계층 펜스가 터빈 캐스케이드내 열전달 특서에 미치는 영향 (Effects of the Inlet Boundary Layer Thickness and the Boundary Layer Fence on the Heat Transfer Chracteristics in a Turbine Cascade)

  • 정지선;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.765-770
    • /
    • 2001
  • The objective of the present study is to investigate the effects of the various inlet boundary layer thickness on convective heat transfer distribution in a turbine cascade endwall and blade suction surface. In addition, the proper height of the boundary layer fences for various inlet boundary layer thickness were applied to turbine cascade endwall in order to reduce the secondary flow, and to verify its influence on the heat transfer process within the turbine cascade. Convective heat transfer distributions on the experimental regions were measured by the image processing system. The results show that heat transfer coefficients on the blade suction surface were increased with an augmentation of inlet boundary layer thickness. However, in a turbine cascade endwall, magnitude of heat transfer coefficients did not change with variation of inlet boundary layer thickness. The results also present that the boundary layer fence is effective in reducing heat transfer on the suction surface. On the other hand, in the endwall region, boundary layer fence brought about the subsidiary heat transfer increment.

  • PDF

불안정 지지면에서 복부 드로잉-인 호흡을 동반한 교각운동 시 사용도구에 따른 복부 근육 두께 및 활성도 비교 (Comparison of the Abdominal Muscle Thickness and Activity by Using Tool and Unstable Surface which is Accompanied Bridge Exercise Doing Abdominal Drawing-in Breath)

  • 김현수;배원식;이건철
    • 대한통합의학회지
    • /
    • 제5권1호
    • /
    • pp.25-34
    • /
    • 2017
  • Purpose : The purpose of this study was to identify comparison of the abdominal muscle thickness and activity by using tool and unstable surface which is accompanied bridge exercise doing abdominal drawing-in breath. Method : This study was performed on normal 13 males and 17 females subjects doing bridge exercise accompanied abdominal drawing-in breath used tools. At this time muscle thickness and muscle activity is measured through ultrasound and EMG. Result : The results of this study, rectus abdominis, internal oblique and transverse abdominis showed a significant difference in muscle thickness when performed using pilates circle. And external oblique showed a significant difference muscle thickness when performed using gym ball. Rectus abdominis and external oblique showed a significant difference in muscle activity when performed using pilates circle. And internal oblique showed a significant difference in muscle activity when performed using sling. Conclusion : Therefore it is suggested that it would be effective to apply the gymball and pilates circle in the unstable surface for abdominal weakness.

볼엔드밀 가공의 칩두께 모델 해석 (Analysis of Chip Thickness Model in Ball-end Milling)

  • 심기중;문상돈
    • 한국공작기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.73-80
    • /
    • 2006
  • This paper describes a analysis on the chip thickness model required for cutting force simulation in ball-end milling. In milling, cutting forces are obtained by multiplying chip area to specific cutting forces in each cutting instance. Specific cutting forces are one of the important factors for cutting force predication and have unique value according to workpiece materials. Chip area in two dimensional cutting is simply calculated using depth of cut and feed, but not simply obtained in three dimensional cutting such as milling due to complex cutting mechanics. In ball-end milling, machining is almost performed in the ball part of the cutter and tool radius is varied along contact point of the cutter and workpiece. In result, the cutting speed and the effective helix angle are changed according to length from the tool tip. In this study, for chip thickness model analysis, tool and chip geometry are analyzed and then the definition of chip thickness and estimation method are described. The resulted of analysis are verified by compared with geometrical simulation and other research. The proposed chip thickness model is more precise.

안정된 면과 폼 롤러 위에서 한 발 들기 자세 시 초음파를 이용한 복근들의 두께 양상 비교 (Comparisons of Abdominal Muscles Thickness During Single Leg Holding Exercise on Stable Surface and on a Foam Roller Using Ultrasound Imaging)

  • 정도영;고은경;김수정;권오윤
    • 한국운동역학회지
    • /
    • 제20권4호
    • /
    • pp.415-420
    • /
    • 2010
  • The purpose of this study was to compare the thickness of the abdominal muscles during single leg holding exercise (SLH) in a hooked lying position on stable surface and on a foam roller. Healthy twenty subjects who had no medical history of lower extremity or lower back pain were recruited for this study. Muscle thickness of transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) was recorded using real-time ultrasonography during SLH. Paired t-test with Bonferroni adjustment was used to compare the muscles thickness during SLH on stable surface and on a foam roller. The result showed that TrA and IO muscle demonstrated greater thickness during SLH on foam roller than those on the stable surface. This finding suggests that SLH on an unstable foam roller is more effective to increase thicknesses of TrA and IO muscles than stable surface.

비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향 (Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance)

  • 이동우;정모범
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

Effect of Neuromuscular Electrical Stimulation Combined with Traditional Dysphagia Rehabilitation on Masseter Muscle Thickness and Bite Force in Stroke with Dysphagia Patient

  • Lee, Myunglyeol;Lee, Kuija;Kim, Jinuk
    • 국제물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.2365-2369
    • /
    • 2021
  • Background: Patients with dysphagia after stroke are treated with neuromuscular electrical stimulation (NMES), but its effect on masseter muscle thickness and bite force in the oral phase is not well known. Objectives: To investigated the effect of NMES on masseter muscle thickness and occlusal force in patients with dysphagia after stroke. Design: Two group, pre-post design. Methods: In this study, 25 patients with dysphagia after stroke were recruited and allocated to either the experimental or the control groups. Patients in the experimental group were treated with NMES to the masseter muscle at the motor level for 30 minutes and were additionally treated with traditional swallowing rehabilitation for 30 minutes. In contrast, patients in the control group were only treated with traditional swallowing rehabilitation for 30 minutes. Masseter muscle thickness was measured using ultrasonography before and after intervention, and bite force was measured using an bite force meter. Results: The experimental group showed significant improvement in masseter muscle thickness and bite force compared to the control group. Conclusion: NMES combined with traditional dysphagia rehabilitation is effective in improving masseter muscle thickness and bite force in patients with dysphagia after stroke.

P형 Bi0.5Sb1.5Te3 박막의 열전 특성에 미치는 두께 및 어닐링 효과 (Thickness and Annealing Effects on the Thermoelectric Properties of P-type Bi0.5Sb1.5Te3 Thin Films)

  • 김일호;장경욱
    • 한국재료학회지
    • /
    • 제14권1호
    • /
    • pp.41-45
    • /
    • 2004
  • P-type $Bi_{0.5}$$Sb_{1.5}$ $Te_3$ thin films were deposited by the flash evaporation technique, and their thermoelectric properties and electronic transport parameters were investigated. The effective mean free path model was adopted to examine the thickness effect on the thermoelectric properties. Annealing effects on the carrier concentration and mobility were also studied, and their variations were analyzed in conjunction with the antisite defects. Seebeck coefficient and electrical resistivity versus inverse thickness showed a linear relationship, and the effective mean free path was found to be 3150$\AA$. No phase transformation and composition change were observed after annealing treatment, but carrier mobility increased due to grain growth. Carrier concentration decreased considerably due to reduction of the antisite defects, so that electrical conductivity decreased and Seebeck coefficient increased. When annealed at 473 K for 1 hr, Seebeck coefficient and electrical conductivity were $160\mu$V/K and 610 $W^{-1}$ $cm^{ -1}$, respectively. Therefore, the thermoelectric quality factor were also enhanced to be $16\mu$W/cm $K^2$.>.

Evidence-based use of cold for plantar fasciitis

  • Laymon, Michael S.;Petrofsky, Jerrold S.;Alshammari, Faris;Fisher, Stacy
    • Physical Therapy Rehabilitation Science
    • /
    • 제2권2호
    • /
    • pp.75-80
    • /
    • 2013
  • Objective: The purpose of this study was to examine the effect of cold applied the night before or in the morning on pain and symptoms of plantar fasciitis. Design: Experimental study. Methods: Thirty subjects with plantar fasciitis were recruited for this study. Subjects with plantar fasciitis either had no intervention, cold applied (20 minutes) at night before bed, or 20 minutes in the morning upon wakening. Plantar fascia tenderness and pain were evaluated. There were ten subjects in each group. Measures included visual analog scale, plantar facial thickness via high resolution ultrasound, algometer measure, and range of motion of the ankle and foot. There were 3 groups of 10 subjects, control (no intervention), cold the night before bed, and cold in the morning before rising. Results: The greatest relief of symptoms was cold used at bedtime the night before the measurements. Cold used in the morning was not as effective as cold used in the evening before bed. Cold use reduced the thickness of the plantar fascia and irritation. There was a 13% reduction in plantar fascia thickness with cold the night before (p<0.05), a 44% reduction in pain and an 86 % increase in the force that could be applied to the bottom of the foot without pain (p<0.05). Conclusions: Cold applied for 20 minutes prior bedtime is effective for reduced symptomology caused by plantar fascia inflammation.

타운 재목(材木)의 천연건조(天然乾燥) 특성(特性) 및 캘린더에 관한 연구(硏究)(I) (Study on Air-drying Characteristics of Taun Lumber and Air-dring Calendar(I))

  • 정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권3호
    • /
    • pp.27-33
    • /
    • 1985
  • Air-drying tests were carried out on green taun (Pometia pinnata f glabra) for 25-mm and 50-mm thickness to elucidate drying characteristics on air-drying rate, time and defects in spring and air-drying calendar. The results of this study were as follows: 1. The air-dried lumber for 25-mm thickness from an initial average moisture content (MC) of $58.3{\pm}3.5$ percent reached 30 percent MC in 17 days, 25 percent MC in 24 days, 20 percent MC in 38 days and 15 percent MC in 84 days. 2. The air-dried lumber for 50-mm thickness from an initial average MC of $59.6{\pm}5.0$ percent reached 30 percent MC in 39 days, 25 percent MC in 55 days and 20 percent MC in 84 days. 3. Air-drying calendar that could be useful in estimating drying times for each month developed by the use of climatological data for Suwon. Total number of effective air-drying days during a year were 243.5 days and the major determinant of the effect air-drying days was temperature. 4. The air-drying rates for 25-mm and 50-mm coated lumber were slight1y slower than those of uncoated lumber. The number and total length of both end checks and surface checks for end coated lumber were less severe than those of uncoated lumber.

  • PDF

용접 조건이 소형 용기용 Sn 도금 강재의 와이어 심 용접성에 미치는 영향 (Effect of Welding Parameters on Wire Seam Weldability of Tin Coated Steels for Small Containers)

  • 김기철;이기호;이목영
    • Journal of Welding and Joining
    • /
    • 제15권5호
    • /
    • pp.74-83
    • /
    • 1997
  • Effect of welding parameters such as current, speed and electrode pressure on the weld quality of tin coated steels for small containers was discussed in this paper. Welding was performed with low frequency wire seam welding system which was loaded with 1.5mm in diameter copper wire electrode. The welding parameters were monitored at the position close to the welding spot so as to minimize the instrumentation error, and the signals were stored into a digital data acquisition system before analysis. Results showed that critical current for sufficient nugget size increased as the base material thickness increased, while the width of the optimum welding range was reduced. The acceptable welding condition derived from this study was found to be effective within the thickness range of $\pm$10% of the nominal (0.25mm) thickness. Tin coating layer was proved not to affect seriously on the weld quality, i.e. strength and formability, since consumable wire electrode was used in this process. Test results also demonstrated that the welding current was thought to be the most effective parameter to form an acceptable weld, while welding speed or electrode pressure exerted less effect on the nugget formation. However, these two parameters played an important role because the former was related to the nugget overlap interval, and the latter, to the formation of expulsion during welding.

  • PDF