• Title/Summary/Keyword: Effective Spectrum Sensing

Search Result 58, Processing Time 0.025 seconds

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Compression Sensing Technique for Efficient Structural Health Monitoring - Focusing on Optimization of CAFB and Shaking Table Test Using Kobe Seismic Waveforms (효율적인 SHM을 위한 압축센싱 기술 - Kobe 지진파형을 이용한 CAFB의 최적화 및 지진응답실험 중심으로)

  • Heo, Gwang-Hee;Lee, Chin-Ok;Seo, Sang-Gu;Jeong, Yu-Seung;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.23-32
    • /
    • 2020
  • The compression sensing technology, CAFB, was developed to obtain the raw signal of the target structure by compressing it into a signal of the intended frequency range. At this point, for compression sensing, the CAFB can be optimized for various reference signals depending on the desired frequency range of the target structure. In addition, optimized CAFB should be able to efficiently compress the effective structural answers of the target structure even in sudden/dangerous conditions such as earthquakes. In this paper, the targeted frequency range for efficient structural integrity monitoring of relatively flexible structures was set below 10Hz, and the optimization method of CAFB for this purpose and the seismic response performance of CAFB in seismic conditions were evaluated experimentally. To this end, in this paper, CAFB was first optimized using Kobe seismic waveform, and embedded it in its own wireless IDAQ system. In addition, seismic response tests were conducted on two span bridges using Kobe seismic waveform. Finally, using an IDAQ system with built-in CAFB, the seismic response of the two-span bridge was wirelessly obtained, and the compression signal obtained was cross-referenced with the raw signal. From the results of the experiment, the compression signal showed excellent response performance and data compression effects in relation to the raw signal, and CAFB was able to effectively compress and sensitize the effective structural response of the structure even in seismic situations. Finally, in this paper, the optimization method of CAFB was presented to suit the intended frequency range (less than 10Hz), and CAFB proved to be an economical and efficient data compression sensing technology for instrumentation-monitoring of seismic conditions.

The Analysis of Spectral characteristics of Water Quality Factors Uisng Airborne MSS Data (Airborne MSS 자료를 이용한 수질인자의 분광특성 분석)

  • Dong-Ho Jang;Gi-Ho Jo;Kwang-Hoon Chi
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.296-306
    • /
    • 1998
  • Airborne MSS data is regarded as a potentially effective data source for the measurement of water quality and for the environmental change of water bodies. In this study, we measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be reached in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. We also investigated the possibility of extraction of water quality factors in water bodies by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract environmental factors related with eutrophication such as chlorophyll-a, suspended sediments and turbidity, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. Although it was difficult to explicitly correlate Airborne MSS data with water quality factors due to the insufficient number of ground truth data. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation could be found. The spectrum was reached highest at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible bands. Second, as a result of the radiance reflectance Chlorophyll-a represented high mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$, respectively. Finally, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution image after carrying out ratio of B3 and B5 to B7. Band 7 was useful for making the distribution image of suspended sediments. When we carried out PCA, suspended sediments and turbidity had distributions at PC 1 and PC 4 which are similar to the ground data. Above results can be changed according to the change of season and time. Therefore, in order to analyze the environmental factors of water quality by using LRC data more exactly, we need to investigate the ground data and the radiance feature of reflectance of water bodies constantly. For further studies, we will constantly analyze the radiance feature of the surface of water in wafter bodies by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFS). We will also gather the data of water quality analysis in water bodies and analyze the pattern of water pollution.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

Energy Harvesting Technique for Efficient Wireless Cognitive Sensor Networks Based on SWIPT Game Theory

  • Mukhlif, Fadhil;Noordin, Kamarul Ariffin Bin;Abdulghafoor, Omar B.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2709-2734
    • /
    • 2020
  • The growing demand to make wireless data services 5G compatible has necessitated the development of an energy-efficient approach for an effective new wireless environment. In this paper, we first propose a cognitive sensor node (CSN) based game theory for deriving energy via a primary user-transmitted radio frequency signal. Cognitive users' time was segmented into three phases based on a time switching protocol: energy harvest, spectrum sensing and data transmission. The proposed model chooses the optimal energy-harvesting phase as the effected factor. We further propose a distributed energy-harvesting model as a utility function via pricing techniques. The model is a non-cooperative game where players can increase their net benefit in a selfish manner. Here, the price is described as a function pertaining to transmit power, which proves that the proposed energy harvest game includes Nash Equilibrium and is also unique. The best response algorithm is used to achieve the green connection between players. As a result, the results obtained from the proposed model and algorithm show the advantages as well as the effectiveness of the proposed study. Moreover, energy consumption was reduced significantly (12%) compared to the benchmark algorithm because the proposed algorithm succeeded in delivering energy in micro which is much better compared to previous studies. Considering the reduction and improvement in power consumption, we could say the proposed model is suitable for the next wireless environment represented in 5G.

Two-Dimensional Arrays of Gold Nanoparticles for Plasmonic Nanosensor

  • Sim, Brandon;Monjaraz, Fernando;Lee, Yong-Joong;Park, So-Yeun
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.525-531
    • /
    • 2011
  • Two dimensional (2D) arrays of noble metal nanoparticles are widely used in the sensing of nanoscale biological and chemical events. Research in this area has sparked considerable interest in many fields owing to the novel optical properties, e.g., the localized surface plasmon resonance, of these metallic nanoarrays. In this paper, we report successes in fabricating 2D arrays of gold nano-islands using nanosphere lithography. The reproducibility and the effectiveness of the nano-patterning method are tested by means of spin coating and capillary force deposition. We found that the capillary force deposition method was more effective for nanospheres with diameters greater than 600 nm, whereas the spin coating method works better for nanospheres with diameters less than 600 nm. The optimal deposition parameters for both methods were reported, showing about 80% reproducibility. In addition, we characterize gold nano-island arrays both geometrically with AFM as well as optically with UV-VIS spectrometry. The AFM images revealed that the obtained nano-arrays formed a hexagonal pattern of truncated tetrahedron nano-islands. The experimental and theoretical values of the geometric parameters were compared. The 2D gold nano-arrays showed strong LSPR in the absorption spectra. As the nano-islands increased in size, the LSPR absorption bands became red-shifted. Linear dependence of the plasmon absorption maximum on the size of the gold nano-islands was identified through the increment in the plasmon absorption maximum rate for a one nanometer increase in the characteristic length of the nano-islands. We found that the 2D gold nano-arrays showed nearly seven-fold higher sensitivity of the absorption spectrum to the size of the nano-islands as compared to colloidal gold nano-particles.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Vegetation Cover Type Mapping Over The Korean Peninsula Using Multitemporal AVHRR Data (시계열(時系列) AVHRR 위성자료(衛星資料)를 이용한 한반도 식생분포(植生分布) 구분(區分))

  • Lee, Kyu-Sung
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.4
    • /
    • pp.441-449
    • /
    • 1994
  • The two reflective channels(red and near infrared spectrum) of advanced very high resolution radiometer(AVHRR) data were used to classify primary vegetation cover types in the Korean Peninsula. From the NOAA-11 satellite data archive of 1991, 27 daytime scenes of relatively minimum cloud coverage were obtained. After the initial radiometric calibration, normalized difference vegetation index(NDVI) was calculated for each of the 27 data sets. Four or five daily NDVI data were then overlaid for each of the six months starting from February to November and the maximum value of NDVI was retained for every pixel location to make a monthly composite. The six bands of monthly NDVI composite were nearly cloud free and used for the computer classification of vegetation cover. Based on the temporal signatures of different vegetation cover types, which were generated by an unsupervised block clustering algorithm, every pixel was classified into one of the six cover type categories. The classification result was evaluated by both qualitative interpretation and quantitative comparison with existing forest statistics. Considering frequent data acquisition, low data cost and volume, and large area coverage, it is believed that AVHRR data are effective for vegetation cover type mapping at regional scale.

  • PDF