• Title/Summary/Keyword: Effective SNR

Search Result 169, Processing Time 0.026 seconds

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Assessment of Effective Dose by using additional Filters in Dental Radiography: PC-Based Monte Carlo Program Analysis Subjected on Intraoral Radiography (치과 방사선 촬영의 부가 필터 사용에 따른 유효선량 평가: 구내 촬영에 대한 PC-Based Monte Carlo Program 분석)

  • Kwak, Jong Hyeok;Kim, A Yeon;Kim, Gyeong Rip;Cho, Hee Jung;Moon, Sung Jin;Kil, Sang Hyeong;Lee, Jong Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.491-498
    • /
    • 2021
  • In this study, the effective dose was measured using the PCXMC v2.0 program by examining the conditions used to set the diagnostic reference level for intraoral imaging recommended by the government, and the effect of the Al additive filter was confirmed. In oral imaging, the largest effective dose was calculated from the oral mucosa among 11 organs. The effect of the Al additive filter showed an excellent radiation reduction effect at 2mm rather than 1mm. In the case of children aged 5 years, the overall effective dose was calculated to be high in all 11 organs because they are more sensitive to radiation than adults. And as a result of evaluating the image quality according to the use of an additional filter during intraoral imaging, there was no significant difference in SNR and CNR changes compared to before the additional filter was used. Based on this study, it is thought that additional filter settings can be recommended for intraoral imaging.

Improved Acoustic Modeling Based on Selective Data-driven PMC

  • Kim, Woo-Il;Kang, Sun-Mee;Ko, Han-Seok
    • Speech Sciences
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2002
  • This paper proposes an effective method to remedy the acoustic modeling problem inherent in the usual log-normal Parallel Model Composition intended for achieving robust speech recognition. In particular, the Gaussian kernels under the prescribed log-normal PMC cannot sufficiently express the corrupted speech distributions. The proposed scheme corrects this deficiency by judiciously selecting the 'fairly' corrupted component and by re-estimating it as a mixture of two distributions using data-driven PMC. As a result, some components become merged while equal number of components split. The determination for splitting or merging is achieved by means of measuring the similarity of the corrupted speech model to those of the clean model and the noise model. The experimental results indicate that the suggested algorithm is effective in representing the corrupted speech distributions and attains consistent improvement over various SNR and noise cases.

  • PDF

A Selection Method of Optimal Digital Low-pass Differentiator for Spike Detection of Surface Motor Unit Action Potential (표면 운동단위 활동전위 스파이크 검출을 위한 최적의 디지털 저역통과 미분기 선정 방법)

  • Lee, Jin;Kim, Sung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1951-1958
    • /
    • 2011
  • The objective of this study is to analyze the performance of digital low-pass differentiators(LPD) and then to provide a method to select effective LPD filter, for detecting spikes of surface motor unit action potentials(MUAP). The successful spike detection of MUAPs is a first important step for EMG signal decomposition. The performances of simple and weighted LPD(SLPD and WLPD) filters are analyzed based on different filter lengths and varying MUAPs from simulated surface EMG signals. The SNR improving coefficient and effective MUAP duration range from the analysis results can be used to select proper LPD filters under the varying conditions of surface EMG.

Performance Enhancement of Multi-Band OFDM using Spectrum Equalizer

  • Yoon, Sang-Hun;Jung, Jun-Mo
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.6
    • /
    • pp.687-689
    • /
    • 2010
  • In this paper, the equalization for frequency slope of path loss in Multi-Band(MB) OFDM UWB is proposed. The path loss of a signal is proportionate to the square of the signal's frequency. So, the received signal amplitudes of OFDM subcarrier can be different up to 3dB when MB-OFDM occupies bandwidth over 1.5GHz. The differences of subcarrier-amplitudes make an effective of 0.3 bit reduction of soft decision bits of viterbi decoder, and when the effective of 0.3 bit reduction can cause 0.5dB SNR degradation. This paper proposes two modem architectures which compensate for the degraded subcarrier by multiplying the reciprocal of degraded values in analog or digital domain. It is shown that, for the proposed architecture applied to MB-OFDM UWB, the performance improvements up to 0.5dB can be obtained over the conventional uncompensated receiver architecture.

Effective Asymptotic SER Performance Analysis for M-PSK and M-DPSK over Rician-Nakagami Fading Channels (Rician-Nakagami 페이딩 채널에서 M-PSK와 M-DPSK 시스템에 대한 효과적인 점근적 심볼 에러 확률 성능 분석)

  • Lee, Hoojin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2177-2182
    • /
    • 2016
  • Using the existing exact but quite complicated symbol error rate (SER) expressions for M-ary phase shift keying (M-PSK) and M-ary differential phase shift keying (M-DPSK), we derive effective and concise closed-form asymptotic SER formulas especially in Rician-Nakagami fading channels. The derived formulas can be utilized to efficiently verify the achievable error rate performances of M-PSK and M-DPSK systems for the Rician-Nakagami fading environments. In addition, by exploiting the modulation gains directly obtained from the asymptotic SER formulas, we also theoretically demonstrate that M-DPSK suffers an asymptotic SER performance loss of 3.01dB with respect to M-PSK for a given M in Rician-Nakagami fading channels at high signal-to-noise ratio (SNR).

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.

A Study on Development of the Low Electrical Power Echo Sounder System for Coastal Use (연안목적용 저출력 어군탐지기 음향계의 개발에 관한 연구)

  • Park, Ju-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.243-250
    • /
    • 2009
  • The expression of signal to noise ratio (SNR) is derived for the individual echo sounder and for the general specifications of commercial echo sounder. The SNR is depicted by several factors on transmitting and receiving, sound propagation, scattering by fishes, and mainly self ship noise. The detection ranges of echo sounders in depth and breadth are derived by finding the border of an acceptable SNR. The detection ranges are computed for the echo sounders of individual and general specifications. Generally, the detection range is lager for low frequencies. Increasing an electrical power and a diameter of transducer is not as effective for high frequencies as for low frequencies to increase the detection range. The theoretical results of the detection range can be applied to design low electrical power echo sounder for coastal use, to select an appropriate echo sounder, to know the capability of a sounder, and to interpret echograms. A method for evaluating and designing low electrical power echo sounder is developed. A universal diagram for the basic design of the low electrical power echo sounder where SNR is plotted against frequency is developed. An appropriate frequency, transducer diameter, and beam width are easily determined by using the diagram.

  • PDF

System Design and Evaluation of Digital Retrodirective Array Antenna for High Speed Tracking Performance (고속 추적 특성을 위한 디지털 역지향성 배열 안테나 시스템 설계와 특성 평가)

  • Kim, So-Ra;Ryu, Heung-Gyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.623-628
    • /
    • 2013
  • The retrodirective array antenna system is operated faster than existing techniques of beamforming due to its less complexity. Therefore, it is effective for beam tracking in the environment of fast vehicle. On the other hand, it also has difficulty in estimating AOA according to multipath environment or multiuser signals. To improve the certainty of estimating AOA), this article proposes hybrid digital retrodirective array antenna systme combined with MUSIC algorithm. In this paper, the digital retrodirective array antenna system is designed according to the number of antenna array by using only one digital PLL which finds angle of delayed phase. And we evaluate the performance of the digital retrodirective array antenna for the high speed tracking application. Performance is studied by simulink when the speed of mobile is 300km/h and the distance between transmitter and receiver is 100m and then we have to confirm the performance of the system in multi path environment. As a result, the mean of AOA (Angle Of Arrival) error is $4.2^{\circ}$ when SNR is 10dB and it is $1.3^{\circ}$ when SNR is 20dB. Consequently, the digital RDA shows very good performance for high speed tracking due to the simple calculation and realization.