• Title/Summary/Keyword: Effective Impedance

Search Result 366, Processing Time 0.028 seconds

A Method to Arrange Absorptive Materials on Walls for Effective Interior Noise Control (효율적 실내 소음 저감을 위한 흡음재 분포 위치 결정 방법)

  • 김양한;조성호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.303-309
    • /
    • 2004
  • Absorptive material arrangement method for effective interior noise control is proposed. Sound field with arbitrary boundary condition is formulated by Kirchhoff-Helmholtz integral equation. A simple example such as a rectangular cavity will present physical meaning between changing boundary condition and control of sound field. The effect of changing boundary condition is expressed in modal admittance. From this formulation. an admittance map is presented. The admittance map is the figure to represent position where absorptive material is attached for effective interior noise control. The admittance map can be assigned to each resonant frequency. There. however, may be common area of those maps. Then, frequency robust arrangement of absorptive material in noise control will be presented.

Analysis of the Coplanar Waveguide Shielded by Rectangular Waveguide (구형 도파관으로 차폐된 코플래너 도파관 해석)

  • 황정섭;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.7
    • /
    • pp.19-25
    • /
    • 1993
  • By using the point matching method, the coplanar waveguide shielded by the rectangular waveguide has been analyzed. The particular potential solution of C.P.W has been obtained from the boundary condition by using the point matching method. The line capacitance has been obtained from the total charge of the center conductor per length. The effective dielectric constant and the line impedance have been obtained from the line capacitance of C.P.W.

  • PDF

Interface Reaction Between LSMC and YSZ and Impedance Properties (LSMC와 YSZ의 계면반응 및 임피던스 특성)

  • 김재동;김구대;문지웅;김창은;이해원
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.9
    • /
    • pp.899-904
    • /
    • 1998
  • Interface reaction between LSMC and YSZ is discussed with chemical composition of LSMC. The reac-tivity between LSMC and YSZ increased with increasing Co amount and A-site deficient perovskite is very effective on reducing reactivity. The (La0.8Sr0.2)xMn0.8Co0.2O3 (X=0.9-1) composition is not reactive with YSZ in experimental range. The electrode reaction reaction resistance increases due to reaction product.

  • PDF

Dispersionless transmission line and the characterization using leaky circuit board for high speed and high density digital circuits (고속/고밀도 디지털 회로를 위한 기판을 이용하는 무왜곡 전송 구현 및 해석)

  • 이중호;윤상기;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.8
    • /
    • pp.1-7
    • /
    • 1998
  • This paper reports a dispersion compensation technique to implement tje distortionless transmission line by satisfying the heaviside conditon. Because of the skin depth for aconductor, compensation condition is dependent on the freuqncy variation. For this reason, first, the resistance have been chaacterized in awide range of frequencies, and then found the effective conductivity of the substrate which satisfied the heaviside condition. The phase velocity and the characteristics impedance are prresented nearly constant over a wideband frequency range.

  • PDF

Mother Wavelet Transform Suitable to Fault Method Algorism (고장 표정 알고리즘에 적합한 원형 웨이브릿 변환)

  • Park, In-Deok;Lee, Seung-Hwan;Kim, Si-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.62_63
    • /
    • 2009
  • This paper is distribution utility to generation of analysis fault several cases on the ground of substation in a energy meter three phase current, voltage data measurement to fault type and characteristics. Mother wavelet transformation of suitable to method algorism from the distribution utility to generation of fault in image impedance etc several parameter for utility characteristics effective to probatory.

  • PDF

Analysis of the Shielded Suspended Substrate Strip Transmission Line (차폐된 서스펜디드 섭스트레이트 스트립 전송선 해석)

  • 황정섭;백경훈;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.53-59
    • /
    • 1994
  • The characteristics of the shielded suspended substrate strip transmission line(SSSL) are analyzed by the point matching method and the variational method in Quasi-TEM mode. The accuracy of this solution is confirmed by analyzing and comparing this solution with the empirical solution obtained from the same dimension. The characteristic impedance and the effective dielectric constant are also studied by increasing the air-layer height of SSSL.

  • PDF

Analysis of the Shielded Coplanar Waveguide by Using the Variational Method (변분법을 이용한 차폐된 코플래너 도파관 해석)

  • 황정섭;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.36-42
    • /
    • 1993
  • By the variational method, the coplanar waveguide(C.P.W) shielded by two conducting plates has been analyzed. The particular potential solution has been obtained for the boundary conditions in C.P.W. The characteristic impedance and the effective dielectric constant in C.P.W. have been obtained by the variational method using the potential function and the assumed basis function for charge distributions. To consider the effect of the conducting plate in C.P.W. two cases, with and without the top plate, have been analyzed and compared respectively.

  • PDF

Mother Wavelet Transform using Distribution Utility of Fault Point Extraction (원형 웨이브릿 변환을 이용한 배전계통의 고장점 추출)

  • Park, In-Deok;Lee, Seung-Hwan;Choi, Kwang-Jin;Kim, Si-Kyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1855-1860
    • /
    • 2009
  • This paper caused a distribution utility to generation of analysis fault several cases on the ground of substation in a energy meter three phase current, voltage data measurement to fault type and characteristics. Mother wavelet transformation of suitable to method algorithm from the distribution utility to generation of fault in image impedance etc several parameter for utility characteristics effective to probatory fault point extraction.

Impedance-based Long-term Structural Health Monitoring for Jacket-type Tidal Current Power Plant Structure in Temperature and Load Changes (온도 및 하중 영향을 고려한 임피던스 기반 조류발전용 재킷 구조물의 장기 건전성 모니터링)

  • Min, Jiyoung;Kim, Yucheong;Yun, Chung-Bang;Yi, Jin-Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5A
    • /
    • pp.351-360
    • /
    • 2011
  • Jacket-type offshore structures are always exposed to severe environmental conditions such as salt, high speed of current, wave, and wind compared with other onshore structures. In spite of the importance of maintaining the structural integrity for offshore structure, there are few cases to apply structural health monitoring (SHM) system in practice. The impedance-based SHM is a kind of local SHM techniques and to date, numerous techniques and algorithms have been proposed for local SHM of real-scale structures. However, it still requires a significant challenge for practical applications to compensate unknown environmental effects and to extract only damage features from impedance signals. In this study, the impedance-based SHM was carried out on a 1/20-scaled model of an Uldolmok current power plant structure under changes in temperature and transverse loadings. Principal component analysis (PCA) was applied using conventional damage index to eliminate principal components sensitive to environmental change. It was found that the proposed PCA-base approach is an effective tool for long-term SHM under significant environmental changes.

Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media (다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석)

  • Kim, Yoon-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.61-67
    • /
    • 2010
  • A characterization procedure for analyzing symmetric coupled MIS(Metal-Insulator-Semiconductor) transmission line is used the same procedure as a general single layer symmetric coupled line with perfect dielectric substrate from the extraction of the characteristic impedance and propagation constant for even- and odd-mode. In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain (FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Symmetric coupled MIS transmission line parameters for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.