• Title/Summary/Keyword: Effective Area

Search Result 6,990, Processing Time 0.045 seconds

A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter (복부직경에 따른 CT유효선량 및 화질변화 비교 분석)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.821-826
    • /
    • 2018
  • This study was performed randomly from all the patients who visited the University Hospital in Gyeonggi-do from January 1, 2018 to June 30, 2018 for the abdominal CT scan. We divided the patients into three groups and evaluated the extent of effective dose and image quality according to the area of the abdominal CT image. As a result, the effective dose was 7.34 mSv in the average area group, 8.39 mSv in the average area and 5.89 mSv in the average area. For the analysis of image quality, ROI was plotted in the same three regions according to the abdominal area. As a result, CT values were significantly different in the abdominal area classified into 3 groups (p <0.05). The results of this study can be used as a basic data for the development of a protocol that can be applied in actual clinical practice. It is thought that it can help to reduce the image quality and the radiation dose.

Physiological Effect on Changes of the Surface Area and the Volume of Limb and Their Effective Measurements (하퇴부(下腿部)의 표면적(表面積) 및 체적변화(體積變化)의 생리적(生理的) 배경(背景)과 측정(測定)에 대(對)한 연구(硏究))

  • Han, Sang-Deok;Lee, Yeong-Suk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.15-21
    • /
    • 1988
  • Changes of the surface area and the volume of limb are important factors for designing clothes and shoes. The limb volume increases slightly in the afternoon in general, because of human activity, as a diurnal variation. Changes are also associated with menstrual cycle, pregnancy, physical exercise and environmental temperature. The most effective method for measuring the surface area of limb is the paper replacement method.

  • PDF

A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz (5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구)

  • Youn, Ju-Shin;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

an Analysis of the Variation on the Impedance Characteristic according to Effective Area of Globe Control Valve at Low Frequency Perturbation (저주파 압력섭동에서 글로브 제어밸브의 유효 단면적에 따른 임피던스 특성 변화 해석)

  • Park, Seungsoo;Yoon, Woongsup;ohm, Wonsuk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.718-723
    • /
    • 2017
  • In this paper, Analytical study is carried out on the impedance characteristics of the globe control valve, which is mainly used for thrust control in liquid rockets, according to the effective area at low frequency perturbation. The impedance tends to increase according to effective area and the cause of impedance characteristic change through flow field visualization is investigated. In the future, the information on the change in the impedance characteristics of the control valve can be used to obtain the impedance of the supply system and it can be utilized to predict pogo phenomenon as well as design accumulator and orifice to reduce the pogo phenomenon.

  • PDF

Experimental Parametric Study on the Rotordynamic Characteristics and Optimal Design of a Flexible Rotor Supported by a Slotted-Ring Electro-Rheological Squeeze Film Damper (슬롯 링 형상을 갖는 전기 유변 스퀴즈 필름 댐퍼로 지지된 연성 로터의 동특성 및 최적설계 파라미터 실험 연구)

  • 이용복;김창호;이남수;최동훈;정시영
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A discharge free Electro-Rheological Squeeze Film Damper (ER-SFD) with predetermined-clearances at leakage ends can inherently eliminate electric discharge problems while still supplying stable leakage control. Test results show that the damping force of the slotted-ring ER-SFD is mainly affected by electric voltage, oil supply pressure, position of the damper and ratio of effective surface area of slotted-rings. As the supply voltage is larger, the amplitudes of both slotted ER-SFD and rotor are decreased at first and second critical speeds. The influence of the oil supply pressure and the effective surface area ratio was shown mainly near the first critical speed. The effective surface area ratio of slotted-rings influences the reduction of flexible rotor vibration. As a result, experimental results confirm that the slotted-ring ER-SFD satisfactorily controls the flexible rotor vibration, while eliminates the inherent electric discharge problems in conventional ER-SFDs.

Water Quality Management of Agricultural Reservoirs Considering Effective Water Depth (농업용 저수지의 유효수심과 수질관리방안)

  • Kim, Hyung-Joong;Kim, Ho-Il
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.95-104
    • /
    • 2010
  • Water quality data for 10 years (2000~2009) from about 826 reservoirs that are operated as a agricultural water quality survey network were analyzed in order to seek water quality management plan based on physical and chemical characteristics of agricultural reservoirs. The 95% reservoirs that exceed agricultural water quality standard of Chl-a (35mg/ $m^3$) had effective water depth shallower than 5m. The reason was that the reservoirs had more inflows of nutrient salts from the watershed, bigger surface water area of weak structure to algae occurrence. As the reservoirs of effective water depth shallower than 5m cover 49% of benefited area for irrigation, it is critical for agricultural water quality management of the reservoirs. The water quality of reservoir with shallower than 5m effective water depth was worse than reservoir with deeper than 5m effective water depth. Therefore, it is desirable that effective water depth of reservoirs make more than 5m for water quality management by building the bank higher and dredging the bottom of reservoirs.

  • PDF

Effect of Inspiratory Muscle Training with Elastic Taping on Forced vital capacity and Sway Area in Stroke Patients

  • Park, Shin Jun
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.121-125
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the forced vital capacity and sway area of respiratory muscles taping with threshold inspiratory muscles training for 1 week. Methods: Nineteen stroke patients were divided into two groups: experimental group (respiratory muscles taping with threshold inspiratory muscles training, n=10) and control group (threshold inspiratory muscles training, n=9). Forced vital capacity tests were performed using a spirometer. The instrument records the forced vital capacity (FVC). COP excursion test was performed using Zebris. The instrument records the sway area. All tests were measured before and after intervention. Results: The experimental group and control group showed significant increase in FVC (p<0.05). The sway area showed a significant decrease only in the experimental group (p<0.05). The FVC and sway area was no significant difference between the two groups (p>0.05). Conclusion: Threshold inspiratory muscles training is an effective intervention for improving FVC. Threshold inspiratory muscles training with respiratory taping is an effective intervention for improving FVC and sway area. Threshold inspiratory muscles training with respiratory taping can improve balance ability.

Studies on Productivity in Meadow Fescue ( Festuce pratensis Huds. ) V. Vertical distribution of leaf area and dry matter production (Meadow fescue의 건물생산량에 관한 연구 V. 엽면적의 수직적 분포와 건물생산)

  • 이주삼;정충섭
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.4 no.3
    • /
    • pp.187-193
    • /
    • 1984
  • Using the stratifying clip method, we examine the differences in vertical distribution of leaf area and its relationships with dry matter production were investigated in the primary swards of six varieties. The results obtained were as follows: 1. The varieties could be classified into 4 different types according to their of vertical distribution of leaf area within the canopy. Thus, M had a greater leaf area distribution in the base layers and became smaller towards the upper layers, Leto, First and Bundy had the leaf area distribution which was most abundant in the middle layers and became smaller towards the base and the upper layers, Tammisto had a greater leaf area distribution in the middle layers and intensively distributed to the upper layers, and Trader had the relatively uniform leaf area distribution over all layers. 2. Effective leaf area index(ELAI) correlated with leaf area index(LAI), dry weight of plant(DW), stem weight of plant(SW) and stem area index(SAI). 3. The variety with the heading tiller type had the effective leaf area intensively distributed to the upper layers of canopy, but the vegetative type showed a high ratio of effective leaf area index. 4. Varietal differenced was found between the effective leaf area and specific leaf weight(SLW) in each stratum above the layer indicating the highest leaf area density within the canopy. M and Trader had a highly negative significant correlation, but the other varieties was not significant correlation.

  • PDF

Experiment on the Effective Helix Area to Determine the Bearing Capacity of Helical Steel Piles (나선형 강관파일의 날개 유효면적 산정을 위한 지지력 실험)

  • Lee, Min-Joo;Kim, Kyoung-Min;Rhim, Hong-Chul;Seo, Gum-Bae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.25-27
    • /
    • 2010
  • Helical steel piles are being widely used in foundation for the buildings in urban areas because of their high compressive and tensile capacities. Helical steel piles have many advantages; ease installation, a vibration-free and low level of noise process, and so on. However, the most researches are about the capacity of helical steel piles under uplift condition. Therefore, this paper focuses on the capacity under compressive loading according to the soil condition. The bearing capacity of helical steel piles varies with the diameter of the helix and shaft and the bearing area of helical steel piles is not always identical with the sum of helix and shaft area due to the difference of each bearing mechanism. Therefore, the experiment with the parameters of the ratio of helix and shaft diameter and soil condition will be carried out to survey the effective helix area under a given soil condition for the bearing capacity of helical steel piles.

  • PDF

Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit (보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정)

  • Zhang, J.F.;Kim, C.T.;Jeong, H.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF