• 제목/요약/키워드: Effective Area

검색결과 7,008건 처리시간 0.037초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

국유림경영(國有林經營)의 합리화(合理化)에 관(關)한 연구(硏究) (A Study on Rationalization of National Forest Management in Korea)

  • 최규련
    • 한국산림과학회지
    • /
    • 제20권1호
    • /
    • pp.1-44
    • /
    • 1973
  • 국유림경영(國有林經營)은 어느 나라를 막론(莫論)하고 그 사명(使命)과 경영목적(經營目的)으로 봐서 중요시(重要視)되고 있다. 한국(韓國)의 국유림(國有林)도 또한 한국경제(韓國經濟)의 비약적(飛躍的)인 발전(發展)에 따라 목림수요(木林需要)의 계속적(繼續的)인 증가(增加)로 국가적(國家的)인 사명(使命)과 산업경제적(產業經濟的)으로 더욱 중요(重要)한 위치(位置)에 놓이게 되었다. 그러나 지금(只今)까지 한국임정(韓國林政)의 주요목표(主要目標)가 산림자원(山林資源)의 보존(保存)과 국토보전기능(國土保全機能)의 회복(回復)에만 급급(汲汲)한 나머지 임업(林業)의 경제생산성(經濟生產性)을 높이는 산업정책적의의(產業政策的意義)가 적었음을 우리는 부인(否認)할 수 없다. 그리하여 한국(韓國)의 임업(林業)도 한국경제구조중(韓國經濟構造中)의 일환(一環)으로서 산업적(產業的)으로 발전(發展)시킬 필요(必要)에 직면(直面)하게 되어 국유림(國有林)도 합리적(合理的)인 산림시업(山林施業)에 기초(基礎)를 둔 산림생산력(山林生產力)의 증강(增强)이 절실(切實)하게 되었고, 그렇게 하므로써 결과적(結果的)으로 우수(優秀)한 산림(山林)이 조성(造成)되어 자연(自然), 산림(山林)의 국토보전기능(國土保全機能) 기타(其他)의 공익적기능(公益的機能)도 발휘(發揮)될 수 있을 것으로 본다. 한국(韓國)의 국유림(國有林)은 1908년(年) 임적계출시(林籍屆出時)의 역사적(歷史的) 소산(所產)으로서 그 후(後) 국토보존(國土保存)과 산림경영(山林經營) 학술연구(學術硏究) 기타(其他) 공익상(公益上) 국유(國有)로 보존(保存)할 필요(必要)가 있는 요존림(要存林)과 이에 속(屬)하지 않는 부요존림(不要存林)으로 구분(區分)하고 요존국유림중(要存國有林中) 국가(國家)가 직접(直接) 임업경영(林業經營)을 목적(目的)으로 하는 산림(山林)은 3개영림서(個營林署)에서 관리(管理)하고 있으며 기타(其他)는 각시도(各市道) 및 타부처소관(他部處所管)으로 되어있는데 국유림(國有林)은 1971년말현재(年末現在) 전국산림면적(全國山林面積)의 19.5%(1,297,708 ha)를 점(占)하고 있으나 임목축적(林木蓄積)은 전국산림총축적량(全國山林總蓄積量)의 50.1%($35,406,079m^3$)를 점(占)하고 연간(年間) 국내용재생산량(國內用材生產量)의 23.6%($205,959m^3$)를 생산(生產)하고 있는 사실(事實)은 한국임업(韓國林業)에 있어 국유림(國有林)이 점(占)하고 있는 지위(地位)가 중요시(重要視)되고 있는 이유(理由)이다. 따라서 국유림경영(國有林經營)의 성패(成敗)는 한국임업(韓國林業)의 성쇠(盛衰)를 좌우(左右)한다고 단언(斷言)할 수도 있을 것이다. 산림(山林)이 가진 모든 기능(機能)이 가 중요(重要)하지만 특(特)히 목재생산(木材生產)은 한국(韓國)과 같이 매년(每年) 막대(莫大)한 외재도입(外材導入)(1971년도(年度)는 $3,756,000m^3$ 도입(導入)에 160,995,000불(弗) 지출(支出))을 필요(必要)로 하는 임업실정(林業實情)임에 비춰 더욱 중요시(重要視)되고 이에 대처(對處)하기 위(爲)한 산림생산력(山林生產力)의 증강(增强)은 시급(時急)한 과제(課題)인 것이다. 그러나 임업생산(林業生產)은 장기생산(長期生產)이기 때문에 경제발전(經濟發展)에 따른 급격(急激)한 목재수요(木材需要)의 증가(增加)에 직시(直時) 대처(對處)하기 어려우므로 장기적(長期的)인 전망(展望)밑에 자금(資金)과 기술(技術)을 효과적(効果的)으로 투입(投入)하고 국유림경영(國有林經營)을 합리화(合理化)하고 능률화(能率化)하여 생산력증강(生產力增强)을 기(期)하여야 할 것이다. 한국(韓國)의 국유림사업(國有林事業)에는 기술적(技術的) 재정적(財政的)인 애로(隘路)와 인건비(人件費)의 증대(增大) 노임(勞賃)의 상승(上昇) 행정제경비(行政諸經費)의 증가등(增加等) 많은 난관(難關)이 가로놓여있다 하겠으나 앞으로의 국유림(國有林)의 발전여부(發展與否)는 사회(社會) 경제(經濟)의 발전(發展)에 적응(適應)한 기술(技術)과 경영방식(經營方式)을 채용(採用)할 수 있느냐 없느냐에 달려있다고 본다. 이러한 관점(觀點)에서 본조사연구(本調査硏究)에서는 한국(韓國)의 국유림경영(國有林經營)의 실태(實態)를 파악분석(把握分析)하고 불합리(不合理)한 문제점(問題點)들을 찾아서 정책적(政策的) 기술적(技術的) 재정적면(財政的面)에서 개선(改善)할 수 있도록 하는데에 본연구(本硏究)의 목적(目的)이 있다. 본논문작성(本論文作成)에 있어 국유림(國有林)의 각종통계(各種統計)는 산림청(山林廳)이 1971년말현재(年末現在) 산림기본통계(山林基本統計) 및 1973년도(年度) 산림사업실적통계(山林事業實績統計)에 의거(依據)하였고 기타(其他)는 현지영림서(現地營林署)에서 얻은 자료(資料)를 인용(引用)하였다. 논자(論者)는 본연구결과(本硏究結果) 다음과 같은 국유림개선방안(國有林改善方案)을 제시(提示)코저 한다. 1) 국유림조직기구(國有林組織機構)에 있어 영림서(營林署)의 증설(增設)로 집약적(集約的)안 국유림경영(國有林經營)을 도모(圖謀)하고 경영계획계(經營計劃係)를 과기구(課機構)로 강화(强化)한다. 2) 보호직원(保護職員)의 증원(增員)으로 1인당책임구역면적(人當責任區域面積)을 1,000~2,000ha 정도(程度)로 축소(縮小)시킨다. 3) 국유림경영(國有林經營) 일선책임자(一線責任者)인 영림서장(營林署長)의 빈번(頻繁)한 인사이동(人事異動)으로 일관성(一貫性)있는 경영계획실행(經營計劃實行)에 차질(蹉跌)을 가져오지 않도록 한다. 4) 경영계획업무(經營計劃業務)에 있어 부실(不實)한 계획(計劃)이 되지 않도록 충분(充分)한 예산(豫算)과 인원(人員)을 배정(配定)하여 기초적(基礎的)인 조사(調査)를 면밀(綿密)히 한다. 5) 1영림서(營林署) 1사업구원칙(事業區原則)을 현실(現實)시키고 1사업구면적(事業區面積)은 평균(平均) 2만(萬) ha 이하(以下)로 한다. 6) 장기차입금(長期借入金)으로 조속(早速)히 미립목지(未立木地)를 입목지화(立木地化)하고 활엽수림(濶葉樹林)의 수종갱신(樹種更新)과 활엽수림(濶葉樹林)의 이용방도(利用方途)를 개발(開發)한다. 7) 조림(造林) 및 양묘사업(養苗事業)의 기계화(機械化) 약제화(藥劑化) 방안(方案)을 강구(講究)하고 실천(實踐)하므로써 노동력(勞動力) 부족(不足)에 대비(對備)한다. 8) 보호사업(保護事業)에 있어 산화피해율(山火被害率)이 외국(外國)에 비(比)하여 막대(莫大) 하므로 제도변(制度面)이나 장비면(裝備面)에서 개선(改善)되어야 하고 방화선(防火線)의 설치(設置) 및 유지(維持)에 필요(必要)한 최소한도(最小限度)의 예산(豫算)을 확보(確保)한다. 9) 제품생산사업(製品生產事業)을 강화(强化)하고 생산(生產) 가공(加工) 유통(流通)을 계열화(系列化)하여 지원민(地元民)에게 경제적혜택(經濟的惠澤)을 준다. 10) 임도망(林道網)의 시설정비(施設整備)와 치산사업(治山事業)은 국유림자체(國有林自體)의 개발(開發)을 위(爲)해서나 지방개발(地方開發)을 위(爲)해서 필요(必要)하므로 일반회계(一般會計)의 부담(負擔)으로 추진(推進)한다. 11) 임업(林業)의 기계화(機械化)는 목재수요(木材需要)의 증대(增大)와 노력부족(勞力不足)에 따라 필연적(必然的)이므로 가계도입(機械導入) 및 국산화(國產化), 사용자(使用者)의 양성(養成) 및 기계관리(機械管理)에 만전(萬全)을 기(期)한다. 12) 노무사정(勞務事情)은 악화(惡化)할 것이 예견(豫見)되므로 임업노동자(林業勞動者)의 확보(確保) 및 복리후생대책(福利厚生對策)을 수립(樹立)한다. 13) 경제변동(經濟變動)에 따른 수지악화시(收支惡化時)에도 일정규모(一定規模)의 지출(支出)을 보장(保障)하기 위(爲)하여 잉여금(剩餘金)의 일부(一部)은 기금(基金)으로 확보(確保)하고 나머지는 확대조림(擴大造林) 임도사업등(林道事業等) 선행투자사업(先行投資事業)에 사용(使用)한다.

  • PDF

기관지 암의 진단에서 형광기관지 내시경검사의 유용성 (Usefulness of LIFE in diagnosis of bronchogenic carcinoma)

  • 이상화;심재정;이소라;이상엽;서정경;조재연;김한겸;인광호;최영호;김학제;유세화;강경호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권1호
    • /
    • pp.69-84
    • /
    • 1997
  • 배경 : 폐암은 13%만이 완치할 수 있는 예후가 불량한 질환으로 조기진단이 중요한 것으로 알려져 있다. 상피내암이나 미세침윤성 기관지암 등의 조기폐암은 조기에 효과적으로 치료할 수 있어 그 진단이 중요하며, 최근에는 전구암 병변도 조기에 진단 가능하므로써 그 예방적인 치료가 시도되고 있다. 조기진단을 위한 객담 세포진 검사나 기존의 기관지 내시경검사는 조기폐암과 전구암 병변에 대한 진단율이 떨어져 진단에 어려운 실정이다. 최근에는 정상과 암세포의 자기형광 (autofluorescence)을 이용한 형광 기관지 내시경(lung imaging fluorescence endoscope device : LIFE)을 통하여 조기 폐암과 전구암 병변의 진단에 효과적인 것으로 알려져 있다. 목적 : 본 연구는 기존의 내시경을 시행하는 환자를 대상으로 형광기관지 내시경 검사를 시행하여 기관지 점막에 이상이 있는 경우 조직검사를 통하여 두 검사 사이에 민감도와 특이도의 차이를 비교하였다. 방법 : 대상환자는 총 35명으로 평균연령 59.3(27-77)세였으며, 남자 26명, 여자 9명이었다. 흉부 방사선상에 폐암 환자 9명, 폐구엽성 무기폐환자 4명, 폐렴환자 3명, 객담에서 악성세포 양성을 보인 2명, 원인 모르는 흉수 환자 2명, 혈담환자 9명, 만성 기침환자 6명이였다. 대상환자 중 악성종양으로 진단된 환자는 15명이였으며, 기존의 백색빛 광원의 기관지 내시경검사와 형광 기관지 내시경 검사를 시행하였으며, 두 검사에 중에 한 검사에서도 이상병변이 있는 경우 조직검사를 시행하여 총 79조직을 얻어 두 검사간에 민강도와 특이도를 비교하여 다음과 같은 결과를 얻었다. 결과 : 1) 총 79조직은 정상조직이 8, 상피세포 증식이 21, 상피세포의 이형성이 23, 침윤성 폐암이 27조직이었다. 2) 상피세포의 이형성인 23조직에서 백색빚 기관지내시경은 14조직에서 양성으로 60.9 % 였으나, LIFE는 19조직에서 양성으로 82.6 %로 높은 경향을 보였다. 3) 27조직의 침윤성 폐암에 대한 백색빛 기관지내시경는 27조직 모두 양성(100%)인 반면에, LIFE는 19조직이 양성으로 70.3 %의 양성율을 나타냈다. LIFE에서 음성으로 보인 8조직의 침융성 폐암은 선암 7조직 중 3조직, 소세포암 8조직 중 5조직이었으며, 이들은 모두 상피조직은 정상이나 암조직이 점막이하에 침윤되어 있었던 조직이었다. 반면에 상피조직에 이상이 있던 7조직의 편평상피 세포암 조직, 1조직의 대세포암, 2조직의 유암과 2조직의 전이성 앙은 모두 양성이었다. 결론 : 이상의 결과로 LIFE는 전구암 병변과 기관지 기관지 폐암증에 상피세포에 이상이 있는 기관지 폐암의 진단에는 백색빛 기관지내시경보다 민감도가 높아 기관지 상피세포에 이상이 있는 전구암 병변과 조기폐암에는 유용할 것으로 사료되나, 기관지 폐암중에 정상의 기관지 점막하에 칩윤하는 기관지 폐암의 진단에는 한계가 있을 것으로 사료된다.

  • PDF

북서태평양에 서식하는 살오징어(Todarodes pacificus) 계군 분석에 대한 고찰 (Stock Identification of Todarodes pacificus in Northwest Pacific)

  • 김정연;문창호;윤문근;강창근;김경렬;나태희;최은정;이충일
    • 한국해양학회지:바다
    • /
    • 제17권4호
    • /
    • pp.292-302
    • /
    • 2012
  • 본 종설논문은 살오징어의 기존 및 최근에 새롭게 적용되고 있는 계군 분석방법들을 비교 분석하여 각 분석방법의 장단점과 분석방법간의 상호보완에 대하여 고찰하였다. 살오징어는 북서태평양의 넓은 지역을 회유하는 어종으로 생태계 및 상업적으로 중요한 자원이다. 살오징어는 해양환경변화의 생물학적 지표로서의 가능성을 평가 받고 있으며, 장단기적인 어획량 및 분포역의 변화가 환경 변화와 함께 나타난다. 예를 들어, 1987/1988 무렵에 발생한 기후체제전환 이후 한류성 어종으로 분류되는 명태의 어획량은 급감하여 현재까지 그 영향이 지속되고 있는 반면, 살 오징어 어획량은 크게 증가하였다. 현재까지 명태 어획량의 감소에 대하여 남획과 기후변화에 초점이 맞추어진 해석이 있으나, 뚜렷한 원인 분석은 이루어지지 않고 있다. 그 이유 중 한 가지는 계군 분석에 근거한 생태, 환경적 측면에 대한 정확한 원인 분석이 이루어지지 않고 있는 것과 관련이 된다. 계군은 유사한 생물학적 특징을 가진 개체들이 제한된 영역 내에서 유성생식과정을 통하여 동일한 유전자 풀(gene pool)을 공유하는 집단으로, 동일 계군을 형성하는 개체들은 산란에서 자원으로 가입 후 다시 재생산 과정에 이르기까지 시간 및 공간적으로 각기 다른 환경의 영향을 받을 수 있다. 따라서, 종에 대한 정확한 계군 분석은 자원의 효과적인 관리 및 급격한 변화에 대한 중요한 대응 방안의 역할을 할 수 있다. 살오징어 계군 분석에 적용된 주요 방법은 크게 4가지로 형태학적 방법, 생태학적 방법, 표지방류법, 유전학적 방법이 있다. 형태학적인 방법은 분석방법이 가장 간단하고 다수의 개체를 비교적 쉽게 분석할 수 있지만 각 형질들은 성장기간 동안 환경에 의해 영향을 많이 받게 되어 개체간의 차이가 생긴다. 생태학적 방법은 주로 개체의 생리적인 변화와 분포 및 회유상태, 기생충의 기생상태나 종류 및 기생률 등을 분석, 산란장의 차이를 알아보는 연구이며, 현재 활발히 연구되고 있는 방법으로 유사한 환경에서 생활하는 집단을 알 수 있지만 유전적으로 같은 집단인지는 알기 어렵다. 표지방류법은 직접적인 방법으로 계군의 회유 및 분포, 산란장의 위치를 파악할 수 있지만 수거가 어렵고 초기 단계에는 표식을 하기 어렵다. 수산생물의 계군 분석을 위한 유전학적 방법은 자원관리학적 연구에 관한 기본적 정보를 제공해 왔다. 계군 분석을 위한 유전학적 방법은 이에 사용하는 유전자 마커(marker)의 감도에 따라 결정되며, 유전자 마커의 다형성이 높은 것을 선택해야 한다. 계군 분석을 위한 유전자 마커로는 오랜 기간 동안 동위효소 다형이 사용되어졌으며, 최근에는 mitochondria, microsatellite와 같이 DNA 염기배열 중에서도 변이성이 높은 영역을 선택하여 마커로 이용한 연구가 증가되고 있다. 기존의 형태학적 방법, 표지방류법, 생태학적인 방법들은 살오징어의 생활사, 회유경로, 산란장의 변화 등을 밝혀내어 계군을 파악하는데 많은 기여를 하였지만 여전히 각 해역에 분포하는 살오징어의 계군을 파악하기에는 어려움이 있다. 최근에는 기존의 계군 분석이 지닌 장단점을 비교 분석하여 복합적인 방법의 계군 분석이 이루어지며, 이러한 정보들을 바탕으로 유전학적 방법을 보완한다면 살오징어 자원의 변동에 대한 관리 방안을 마련하는데 도움을 줄 것이다.

수도(水稻)에 대(對)한 심층추비효과(深層追肥効果)에 관(關)한 연구(硏究) - Zeolite 첨가(添加) Ball complex 비료(肥料)의 비효(肥効) - (Study on the Effect of Deep Fertilization on Paddy Field - Efficiency of Ball Complex Fertilizer Mixed with Zeolite -)

  • 김태순;유장걸
    • 한국토양비료학회지
    • /
    • 제10권1호
    • /
    • pp.61-67
    • /
    • 1977
  • 수도(水稻)에 대(對)한 Zeolite 첨가(添加) Ball Complex 비료(肥料)의 심층(深層) 추비(追肥) 방법(方法)과 현행(現行) 표층(表層) 추비법(追肥法)과의 비효(肥効)를 비교(比較)했다. 대조구(對照區)와 Ball Complex 구(區)의 기비(基肥) 질소(窒素)를 동량(同量)으로 시비(施肥)하고 질소(窒素) 추비(追肥)는 대조구(對照區) 3회(回) 표층(表層) 시비(施肥)를 했고, Ball Complex 구(區)는 출수(出穗) 전(前) 35일(日)에 12~13cm 깊이로 4주간(株間)에 한개(個)씩 심층(深層) 추비(追肥)를 1회(回)했을 때 얻어진 결과(結果)를 요약(要約) 하면 다음과 같다. 1. Ball Complex 구(區) 수도체(水稻體)는 질소(窒素), 가리(加里)를 수확기(收穫期)까지 지속적(持續的)으로 흡수(吸收)하는데 비(比)해서 대조구(對照區) 수도체(水稻體)는 출수(出穗) 후(後) 부터 이들 양분(養分)의 흡수(吸收)는 급격(急激)히 감소(減少) 경향(傾向)을 보인다. 등숙기(登熟期)에 있어서 수도체(水稻體)의 질소(窒素), 가리(加里) 일당(日當) 흡수량(吸收量)은 대조구(對照區)가 주당(株當) 각각(各各) 0.45mg, 0.68mg에 불과(不過)하나 Ball Complex 구(區)는 각각(各各) 4.8mg 7.0mg 이다. 2. 물질(物質) 생산 속도(速度)는 각(各) 처리구(處理區) 수도(水稻)의 양분(養分) 흡수(吸收) 양상(樣相)이 잘 반영(反映)되어 대조구(對照區)는 출수(出穗) 직후(直後) 최고(最高) 값을 나타 내였다가 등숙기(登熟期)에는 떨어지지만 Ball Complex 구(區)는 오히려 등숙기(登熟期)에 크다. 3. Bali Complex 심층(深層) 추비구(追肥區)는 무효(無効) 분얼(分蘖)이 적어 유효(有効) 경율(莖率)이 높기 때문에 주당(株當) 수수(穗數)는 대조구(對照區) 수도(水稻) 보다 많다. 4. Ball Complex 심층(深層) 추비(追肥)는 수당(穗當) 완전입수(完全粒數), 등숙율(登熟率), 천입중(千粒重) 모두 다 크다. 5. 수량(收量)은 10a당 대조구(對照區)가 423kg이고 Ball Complex 구(區)는 528kg로서 25%가 많았다. 6. 심층(深層) 추비(追肥) 수도체(水稻體)의 형태적(形態的) 특징(特徵)은 지엽(止葉), 제(第)2엽(葉)의 엽신장(葉身長), 엽(葉) 면적(面積)이 표층(表層) 추비(追肥) 수도체(水稻體) 보다 크다. 7. Ball Complex 비료(肥料)의 심층(深層) 추비(追肥)는 등숙기간중(登熟期間中) 질소(窒素), 가리(加里)의 흡수(吸收)가 많아서 엽신중(葉身中)의 질소(窒素) 농도(濃度)를 높이 유지(維持)하기 때문에 수도체(水稻體)의 지엽(止葉), 제(第)2엽(葉)의 엽신(葉身) 신장(伸長)을 촉진(促進)하여 엽(葉) 면적(面積)이 넓어지고 엽신중(葉身重)이 무겁고 단위(單位) 동화능(同化能)을 높여 광합성(光合成) 능력(能力)을 향상(向上) 시킨다. 또한 표층(表層) 추비(追肥) 수도체(水稻體) 보다 하엽(下葉) 고사(枯死)가 적고 생엽수(生葉數)가 많아 수도체(水稻體) 군(群)의 엽면적(葉面積) 지수(指數)의 감소(減少)를 적게 하므로 본시험(本試驗)에서는 현행(現行) 표층(表層) 추비법(追肥法) 보다 더 증수(增收)가 가능(可能)하였다. 8. 이상(以上)과 같은 결과(結果)로 보아서 Ball Complex 비료(肥料)는 현존(現存) 비료(肥料)의 시비(施肥)보다 추비효과(追肥効果)가 컸으며, 추비(追肥) 방법(方法)은 심층(深層) 추비(追肥)가 현행(現行) 표층(表層) 추비법(追肥法) 보다 훨씬 좋았다.

  • PDF

볏짚거적덮기공의 사방효과(砂防効果)에 관(關)한 연구(硏究)(I) - 사면지피조성(斜面地被造成) 및 침식방지(浸蝕防止) 효과(効果) - (Studies on Soil Conservation Effects of the Straw-mat Mulchings (I) - Vegetation Establishment and Erosion Control Effects -)

  • 우보명
    • 한국산림과학회지
    • /
    • 제13권1호
    • /
    • pp.67-78
    • /
    • 1971
  • 우리나라에서 황폐산지(荒廢山地)를 복구녹화(復舊綠化)하기 위하여 시행(施行)되고 있는 산복공중(山腹工中)에서 가장 Weight를 많이 찾이 하고 있는 산복공작물(山腹工作物)은 입지공(立芝工)인데, 입지공(立芝工)은 상하계단(上下階段) 간사면라지(間斜面裸地)를 식피조성(植被造成)하지 못하는 시공자체(施工自體)의 취약점(脆弱點)을 가지고 있다. 입지공(立芝工)이 가진 이러한 단점(短點)을 보완해결(補完解決)하며, 나아가서 급경사(急傾斜)의 황폐침식(荒廢浸蝕)된 산복(山腹)에 속성식피조성(速成植被造成)을 기(期)할 수 있는 효과적(効果的)인 산복녹화공법(山腹綠化工法)을 개발(開發)하고저, 급경사(急傾斜)의 점토질(粘土質) 토양사면(土壤斜面) (사면장(斜面長) 1.6m)에 특별(特別)히 조립(組立)한 볏짚거적 (피복율(被覆率) 약(約) 70%)을 피복(被覆)하고 볏짚거적덮기공이 지표토양유실량(地表土壤流失量) 및 토양수분함유량(土壤水分含有量)과 식피조성(植被造成)에 미치는 효과(効果)를 측정(測定)(측정기간(測定期間) 5~9월(月))한바 그 결과(結果)는 대체로 다음과 같이 요약(要約)될 수 있다. 1. 볏짚거적덮이공이 지표토양유실방지(地表土壤流失防止)에 미치는 효과(効果): 일(一) 각처리별(各處理別) 지표토양유실량(地表土壤流失量)의 합계량(合計量) (표(表) 3참조)은 파종후무피복구(播種後無被覆區)$T_1$에서 4,651 g/$1.6m^2$, 파종후피복구(播種後被覆區)$T_2$에서 163 g/$1.6m^2$, 그리고 피복후파종구(被覆後播種區)$T_3$에서 2, 891 g/$1.6m^2$로 측정(測定)되어, $T_2$$T_1$의 약(約)28.5배(倍), $T_3$의 17.7배(倍), 또 $T_3$$T_1$의 약(約) 1.6배(倍)의 지표토양유실방지효과(地表土壤流失防止効果)가 인정(認定)되었다. (표(表) 2, 3 및 4참조) 2. 볏짚거적덮기공이 사면토양수분함유량(斜面土壤水分含有量)에 미치는 효과(効果): 일처리별(一處理別) 지표면평균토양수분함유량(地表面平均土壤水分含有量)은 $T_1$=21.60%, $T_2$=23.04%, $T_3$=22.21%, 또 지표하(地表下)에서의 그것은 $T_1$=23.81%, $T_2$=26.16% 및 $T_3$=24.81%로 측정(測定)되어, 볏짚거적덮기공이 사면토양수분함유량(斜面土壤水分含有量)에 미치는 효과(効果)에 있어서 고도(高度)의 유의성(有意性)이 인정(認定)되었다. (표(表) 7, 8 및 9 참조) 3. 볏짚거적덮기공이 사면식피조성(斜面植被造成)에 미치는 효과(効果): 일(一) 처리별(處理別) 평균발아본수(平均發芽本數)는 $T_1$=237본(本), $T_2$=246본(本) 및 $T_3$=262본(本)으로 조사(調査)되었으며, 식피율(植被率)(무성기(茂盛期))은 각처리(各處理) 모두 90% 정도(程度)로써 볏짚거적덮기공이 사면식피조성(斜面植被造成)에 미치는 효과(効果)에 있어서는 유의성(有意性)이 인정(認定)되지 아니하였다. 4. 이상(以上)의 결과(結果)를 종합(綜合)해 볼 때에 볏짚거적덮기공은 황폐침식(荒廢浸蝕)된 산복사방공법(山腹砂防工法)으로써 뿐만 아니라 붕양지(崩壤地)와 절개지(切開地)의 사면방호공법(斜面防護工法)으로써 유효(有効)하게 적용(適用)할수 있을것이며, 특(特)히 황폐산지유역(荒廢山地流域)으로부터의 지표토사유실방지상(地表土砂流失防止上) 중요(重要)한 사면녹화공법(斜面綠化工法)이 될 것이다. 5. 본인(本人)은 본(本) 공종(工種)을 새로운 사면녹화공(斜面綠化工)으로써 "볏짚거적덮기공"이라고 호칭(呼稱)하고저 한다.

  • PDF

서울지역 여대생의 BMI를 기준으로 식생활, 영양섭취상태 및 혈액인자 비교 연구 (Comparison of the Dietary Pattern, Nutrient Intakes, and Blood Parameters According to Body Mass Index (BMI) of College Women in Seoul Area)

  • 최경순;신경옥;정근희
    • 한국식품영양과학회지
    • /
    • 제37권12호
    • /
    • pp.1589-1598
    • /
    • 2008
  • 본 연구는 $20{\sim}24$세의 여대생 대상으로 비만유형에 따라 각 군별로 식습관과 식생활 평가, 영양섭취상태 및 혈액인자가 건강에 어떠한 영향을 주는지를 조사하였다. 체질량지수 (BMI)에 따라 저체중군, 정상군, 비만군으로 분류하였을 때, 신장은 군 간에 유의적인 차이가 없었지만, 체중 골격근량 체지방량 제지방량 체지방률 및 waist-hip ratio는 비만군에서 가장 높았다(p<0.05). 조사대상자의 식습관은 매일 아침식사를 하는 경우는 129명 중 저체중군은 36명 27.9%, 정상군은 88명 68.2%, 비만군은 5명 3.9%로 나타났으며, 전체 조사대상자의 아침 식사의 결식률도 15.3%나 되었다. 아침 결식의 이유로는 아침시간이 바쁘거나, 늦게 일어나서 아침을 거르는 경우가 많았으며, 결식으로 인한 배고픔을 간식으로 대체하고 있어 하루에 $1{\sim}2$회 정도 간식을 한다고 답하였다. 식생활 평가를 보면, 저체중군에 속하는 여대생들은 육류, 생선, 알류 등의 단백질 식품의 섭취(23.4%)와 과일 및 과일주스의 섭취(37.8%)를 많이 하는 경향을 보였으며, 비만군에 속하는 여대생들은 삼겹살, 갈비 등 지방이 많은 육류를 주 2회 이상 먹는 비율(77.8%)과 김치 및 채소를 식사 때마다 먹는 비율(66.7%)이 다른 군에 비해 높았다(p<0.05).그러나 비만군에 속한 여대생의 경우 모든 식품을 골고루 섭취하려고 많은 노력을 하였으며, 저체중군에 비해 오히려 비만군에서 식생활과 건강에 더 많은 관심을 보이고 있는 것으로 나타났다. 영양소 섭취상태 중 콜레스테롤 섭취량은 오히려 다른 군에 비해 비만군에서 낮았고(p<0.05), 전체 여대생의 영양소 섭취상태를 한국인 영양섭취기준과 비교해 볼 때, 철, 칼슘, 섬유소의 섭취는 제시된 기준치에 비해 현저히 낮았으며, 소디움의 섭취는 오히려 기준치에 비해 과다하게 섭취하는 것으로 나타났다. 혈액 검사 결과 혈중 총 콜레스테롤, HDL-cholesterol 및 HDL-C/LDL-C(ratio)는 비만군에서 낮았으며, 중성지방 수치는 다른 두 군에 비해 비만군에서 매우 높은 수치를 나타내었다(p<0.05). 혈중 총콜레스테롤은 각각 HDL-cholesterol 및 LDL-cholesterol과 정의 상관관계를 보였으며, 중성지방은 HDL-cholesterol과 역의 상관관계를 보였다. 따라서 본 연구의 결과를 보면, BMI에 의해서 분류된 세 그룹 모두에서 아침 결식률과 운동부족이 문제가 있는 것으로 나타났다. 저체중군에서는 균형적인 영양섭취가 요구되는 것으로 나타났고, 비만군에서는 너무 본인의 신체적 문제를 의식하여 식품의 섭취에 있어서 균형적인 식사를 무시하고, 체중을 줄이려고 편식을 시도하려는 경향이 있는 것이 문제점으로 지적되었다. 따라서 저체중군, 정상군 및 비만군에 상관없이 여대생의 현실에 맞는 전반적인 식생활의 개선과 건강 증진을 위한 영양교육 강화의 필요성 및 체계적인 식사관리 프로그램이 요구됨을 알 수 있었다. 또한 비만인 뿐만 아니라 저체중의 비율도 높아 자신의 건강상태를 올바르게 판단하여 자신에게 맞는 식생활 계획을 세우는 것이 필요하다고 사료된다.

어머니의 식습관, 요리습관 및 운동습관과 학령기 후기 아동의 Broca 체질량지수와의 상관관계 연구 (Relationship between Broca Index of Late School-Aged Children and Their Mothers' Eating, Cooking, and Exercise Habit)

  • 이혜림;이경은;고광석;홍은아
    • 한국식품영양과학회지
    • /
    • 제45권10호
    • /
    • pp.1488-1496
    • /
    • 2016
  • 발달과 성장이 매우 빠르게 진행되는 학령기 아동 및 청소년기에는 비만뿐 아니라 부적절한 저체중 또한 장 단기적으로 많은 건강문제를 초래할 수 있다. 그럼에도 불구하고 이 시기의 비만과 관련된 건강문제 및 개선책에 대한 연구는 활발히 이루어지고 있지만 저체중과 관련된 건강 관련 연구는 상대적으로 미흡한 실정이다. 또한, 실제로 아동의 식습관과 생활습관에 가장 직접적인 영향을 끼치는 요인은 어머니임에도 불구하고, 어머니들의 식습관, 요리습관 및 운동습관과 학령기 아동의 저체중과의 상관관계를 분석한 연구는 특히 국내에서 찾아보기 힘든 실정이다. 이것은 한국 학령기 아동의 저체중을 가져오는 환경적 요인, 그중에서도 가장 큰 요인으로 보고되고 있는 가족의 생활습관에 대한 현실과 연구사이에 큰 괴리(missing gap)가 존재함을 의미한다. 따라서 본 연구는 어머니의 인구 사회학적 특성에 따른 식습관, 요리습관 및 운동습관을 분석하고, 어머니들의 건강과 관련된 생활습관 및 체질량지수가 그들의 학령기 후기 자녀의 체질량지수와 어떠한 상관관계가 있는지를 조사하는 것에 목적을 두고 시행되었다. 본 연구 결과에서 Pearson's correlation 분석을 통한 어머니의 체질량지수와 자녀의 체질량지수는 서로 유의한 상관관계를 보였는데(r=0.345, P<0.001), 이는 어머니의 저체중 정도가 클수록 자녀의 저체중 정도 또한 크다는 것을 의미하는 것으로 학령기 아동들의 체중과 관련하여 일반적으로 가장 친밀하게 관계를 맺는 어머니로부터 강하게 영향을 받는다는 선행연구들의 결과를 재조명해 주었다. 또한, 본 연구 결과를 통해 Broca 지수가 90% 미만인 저체중인 어머니가 82.4%로 다수를 차지하는 것과 연관하여 중년 어머니가 저체중 상태에서 적정수준의 운동을 하지 않음으로 인한 전반적인 체력 저하가 있을 수 있음이 의심되었다. 따라서 어머니의 운동 부족과 건강하지 못한 운동습관이 자녀의 운동에 대한 동기부여와 건강상태에 미치는 영향에 대한 연구가 향후에 이루어져야 함을 제안한다. 주목할 만한 또 다른 연구 결과는 어머니의 체질량지수에 따른 어머니의 식습관, 요리습관은 통계적으로 유의한 차이를 보였다는 것이다. 이는 대다수의 참여자가 저체중인 그룹에 속하는 체질량지수를 가지고 있다고 하더라도 저체중 그룹 내 어머니의 식습관과 요리습관이 좋을수록 체질량지수가 정상에 가까운 것으로 해석될 수 있다. 이 결과는 좋은 식습관과 요리습관이 건강상태와 긍정적 상관관계가 있다는 기존의 선행연구 결과들을 지지함과 동시에 비만뿐만 아니라 저체중 그룹 내에서도 적절한 식습관과 요리 습관이 체질량의 적절한 증가와도 상관관계가 있음을 보여준다. 마지막으로 본 연구 결과에서 자녀의 Broca 체질량지수 분류별 어머니의 Broca 체질량지수의 차이는 유의한 것으로 나타났다(F=7.158, P<0.001). 요리습관만을 사후분석 하였을 때 저체중군이 정상군보다 요리습관의 평균점수가 높아 자녀가 저체중군인 어머니들이 자녀가 정상군에 속한 어머니들보다 더 건강한 식습관을 가진 것으로 나타났다. 학령기 아동은 물론 청소년을 대상으로 자녀의 저체중과 어머니의 요리습관과의 상관관계를 살펴본 선행연구를 거의 찾을 수 없는 실정을 고려할 때 이 두 요인과의 상호 연관성을 제시하였다는 점에서 본 연구의 가치를 찾을 수 있다. 따라서 저체중 그룹 학령기 아동의 건강증진 및 건강문제 예방을 위해 어머니들의 건강한 요리습관 형성을 목적으로 하는 교육 프로그램이 효과적인 중재방법이며 이를 개발하여 그 효과를 증명하는 향후 연구를 제안하는 바이다. 본 연구의 결과들은 학령기 후기 아동의 체질량지수와 학령기 아동의 어머니를 대상으로 하는 식습관, 요리습관 및 운동습관의 다각적 측면을 고려한 맞춤형 건강 교육 프로그램을 개발할 수 있는 기반을 마련함에 동시에, 어머니의 생활습관 변화가 학령기 후기 아동의 저체중 및 과체중에 미치는 긍정적인 효과를 연구하는 중요한 기초자료를 제공함에 그 중요한 의의가 있다고 하겠다.

무부자 쌍끌이 중층망 어구어법의 개발 (III) - 카이트를 부착한 모형어구의 전개성능 - (Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net (III) - Opening Efficiency of the Model Net attaching the Kite -)

  • 유제범;이주희;이춘우;권병국;김정문
    • 수산해양기술연구
    • /
    • 제39권3호
    • /
    • pp.197-210
    • /
    • 2003
  • 무부자망은 망구의 전개 및 예망시 중저층에서의 예방수심 조절이 효과적이었지만, 표층~30m에서는 예망이 어렵다는 것이 확인되었다. 따라서 본 연구는 이것을 극복하기 위하여 카이트(Kite)의 적용을 검토한 것으로 무부자 쌍끌이 중층망의 뜸줄에 연결된 대형망목부에 부분적으로 카이트를 부착하여 회류수조에서 모형실험으로 그 전개성능을 비교 조사하고 우리나라 쌍끌이 중층망에 적용 가능성을 검토하였다. 그 결과를 요약하면 다음과 같다. 1. 예망수심은 카이트망이 기준형과 무부자망보다 유속별 예망수심이 모두 상승하였으며, 실제 조업시의 예망속도 4.9knot일때는 기준으로 2개의 카이트를 부착했을 때는 약 20m였고, 4개의 카이트를 부착했을 때는 약 5m였다. 또한, 카이트망의 추와 날개 끝 추의 무게가 증가함에 따른 예망수심의 변화는 거의 없었으며, 발줄의 깊이만 각각 약15m와 10m 침강하였다. 그리고, 아래끌줄의 길이(dL)의 증가에 따른 예망수심의 변화는 없었고, 발줄의 깊이만 약 22m 침강하였다. 2. 유체저항은 유속이 2.0~5.0knot로 증가함에 따라 거의 직선적으로 증가하였으며, 그 증가율은 유속이 증가함에 따라 커지는 경향을 보였다. 또, 카이트망의 유체저항은 무부자망과 기준형에 비해 약 5~10ton 더 컸다. 그리고, 카이트망의 유체저항은 4.0knot를 기준으로 추의 무게가 1.40~3.50ton 으로 증가할 때 약 3ton, 날개끝 추의 무게가 0~1.11ton으로 증가할 때 약 4ton 증가하였으며, 아래끌줄의 길이(dL)가 0~40m로 증가할 때 유체저항은 약 5.5ton 증가하였다. 3. 망고는 4.0knot를 기준으로 카이트의 면적이 $2,270mm^2(2kite)에서; 4,540mm^2(4kite)$로 증가할 때 약 10m 증가하였으며, 카이트의 면적이 $4,540mm^2$(4kite)일 때 기준망보다는 약 50m, 무부자망보다는 약 30m 증가하였다. 망폭의 변화는 모든 경우에서 유속의 변화에 따라 5m 내외로 거의 일정하였다. 4. 여과량은 카이트망이 기준형과 무부자망에 비해 유속이 2.0knot일 때는 약 28%, 34% 더 컸으며, 3.0knot일 때는 약 42%, 41%이었고, 4.0knot일 때는 약 62%, 45%이었으며, 5.0knot일 때는 약 74%, 54%로 더 컸다. 각 어구별 적정 예망속도는 뜸이 있는 기준형은 약 3.0knot, 무부자망은 4.0knot이상 이였으며, 카이트망은 5.0knot 이상에서도 가능한 것으로 판단된다. 5. 망구면적당 유체저항의 비는 기준형, 무부자형, 카이트망의 순으로 전개효율은 카이트망이 가장 우수하였으며 다음으로 무부자망, 기준형의 순이었다. 실제 예망속도인 4.0knot를 기준으로 카이트망은 기준형에 비해서는 약50%, 무부자형에 비해서는 약 25%로 더 효율적인 것으로 나타났다.