• Title/Summary/Keyword: Effect Measurement

Search Result 6,927, Processing Time 0.035 seconds

Economic Effect of National Measurement Standards (측정표준의 국민경제 기여효과 분석)

  • 안병덕;남경희;안웅환;김동진;조연상
    • Journal of Korea Technology Innovation Society
    • /
    • v.5 no.2
    • /
    • pp.245-256
    • /
    • 2002
  • Measurement standards, as being widely recognized, is necessary for national economic development and advanced industrialization. Also measurement standards give reliability and fair trade to the producers and consumers. Macro-effect of measurement standards using estimation of cost function has four effects: 1) value-added causing effect, 2) effect of employment, 3) reduction effect transaction cost, 4) reduction effect defect rates. In this study, to investigate the impacts between specific and the other industries, we used I-O Table of Korea Bank. The relation between the value-added produced by original production factors and final use is determined through production level, and the relation can be investigated with production causing coefficient matrix. In this study, it was showed that the measurement standards investments including measurement only man power of industries were increased from 1995 rapidly. The establishment and maintenance of measurement standards contributes to reduce the defect rate of products in production process and improve the confidence of the product quality. The results from this study show that measurement technology contributes to improve quality, decrease defect rate, improve production process, develope new products, reduce prime cost and increase the consumer's confidence on the firms. Since these results indicate that measurement standards are very important in the point of their vast contribution, we hope our findings can contribute to encourage measurement activities in industries.

  • PDF

A Method of an Accurate Six Sigma Financial Effect Measurement and Connecting the Financial Effect to the Corporate Income Performance (6시그마 재무성과의 정확한 측정과 기업 손익실적과의 연계 방안)

  • Kim, Ho-In;Jeong, Jae-Ho;Kim, Chan-Mo
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.3
    • /
    • pp.94-101
    • /
    • 2009
  • It is important to measure financial effect of six sigma projects accurately for successful implementation of six sigma in a company. However, researches on methods of six sigma financial effect measurement are relatively new. In this study, frequent error patterns of six sigma financial effect measurement are defined and accurate measurement methods are suggested. And a method of connecting six sigma financial effect to corporate income performance is also suggested which not only assures reliability of financial effect measurement but also helps to align with business strategy.

A Basic Study of Displacement Measurement of Magnetic Bearing System Using Hall Effect Sensor (자기베어링 시스템에서의 변위측정을 위한 홀 효과 센서의 기초 연구)

  • Yang, J.H.;Jeong, G.G.;Jeong, H.H.;Son, S.K.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.72-76
    • /
    • 2007
  • Since the magnetic bearing system has unstability inherently it is necessary to measure the displacement for stable operation. Normally the displacement measurement is implemented by using sensors. The sensor for the displacement measurement is selected by precision, installation space, effect of magnetic field and response speed. And the cost of displacement measurement sensor also is considered. At the cost the hall effect sensor has a large advantage comparing with the others. Therefore this study concern about the basis experimental test for the displacement measurement of the magnetic bearing system that uses the hall effect sensor coupled with a tiny permanent magnet. The experimental results confirm the validity and practicability for this displacement measurement sensor.

  • PDF

An Approach for the Uncertainty Evaluation of the Overall Result from Replications of Measurement: Separately Combining Individual Uncertainty Components According to their 'systematic' and 'random' Effects

  • Kim, In Jung;Kim, Byungjoo;Hwang, Euijin
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1057-1060
    • /
    • 2014
  • In our previous articles, an approach has been proposed for the evaluation of the uncertainty of overall result from multiple measurements. In the approach, uncertainty sources were classified into two groups: the first including those giving same 'systematic' effect on each individual measurement and the second including the others giving 'random' effect on each individual measurement and causing a variation among individual measurement results. The arithmetic mean of the replicated measurements is usually assigned as the value for the overall result. Uncertainty of the overall result is determined by separately evaluating and combining an overall uncertainty from sources of the 'systematic' effect and another overall uncertainty from sources of the 'random' effect. This conceptual approach has been widely adopted in chemical metrology society. In this study, further logical proof with more detailed mathematical expressions is provided on the approach.

The effect of noise and doppler for range measurement of low orbit satellite using tone method (톤 방식을 사용한 저궤도 위성 거리 측정에서의 잡음과 도플러 영향 분석)

  • 김영완;박동철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.641-650
    • /
    • 2000
  • The effects of noise and doppler for low orbit satellite range measurement using tone method are represented in this paper. Also the optimal noise bandwidth of range signal detection circuit which is used for range measurement system of KOMPSAT is proposed. Based on the effects of satellite orbit parameters via the deduction of dynamic motion characteristics of low orbit satellite and signal to noise spectral density of range measurement signal, the effects of noise and doppler for range measurement system are analyzed. The effect of satellite link noise is decreased, but the effect for doppler is increased as the PLL noise bandwidth of range signal detection circuit is increased. The validation of analyzed effect is verified via comparison of measurement results of KOMPSAT's range measurement system and simulation results in environments of low orbit satellite.

  • PDF

An Analysis on the status of Measurement Investment in Korean Industry (한국산업의 계측투자실태분석)

  • Kim, Dong-Jin;Nam, Gyeong-Hui
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.76-93
    • /
    • 1992
  • The purpose of this study, by surveying the status of firms, measurement-related investment and the defect rate, is to analyze the effect of measurement-related investment and to propose a scheme of efficient measurement-related investment which reduces the defect rate. For this project we obtain the data of the status of the measurement-related investment and the defect rate of 928 firms in Korean manufacturing industry by mailing survey. One of our results shows that the firms which have measurement standard laboratory, i.e, which invest in measurement-related area comparatively high, have the defect rate about 0.8% lower than those firms which don't have measurement standard laboratory. Also we find that the small-and-middle size firms have worse measurement-related facility than the large firms and the firms in the heavy-chemical industry have higher measurement-related investment effect than the firms in the light industry.

  • PDF

Exploration of temperature effect on videogrammetric technique for displacement monitoring

  • Zhou, Hua-Fei;Lu, Lin-Jun;Li, Zhao-Yi;Ni, Yi-Qing
    • Smart Structures and Systems
    • /
    • v.25 no.2
    • /
    • pp.135-153
    • /
    • 2020
  • There has been a sustained interest towards the non-contact structural displacement measurement by means of videogrammetric technique. On the way forward, one of the major concerns is the spurious image drift induced by temperature variation. This study therefore carries out an investigation into the temperature effect of videogrammetric technique, focusing on the exploration of the mechanism behind the temperature effect and the elimination of the temperature-caused measurement error. 2D videogrammetric measurement tests under monotonic or cyclic temperature variation are first performed. Features of measurement error and the casual relationship between temperature variation and measurement error are then studied. The variation of the temperature of digital camera is identified as the main cause of measurement error. An excellent linear relationship between them is revealed. After that, camera parameters are extracted from the mapping between world coordinates and pixels coordinates of the calibration targets. The coordinates of principle point and focal lengths show variations well correlated with temperature variation. The measurement error is thought to be an outcome mainly attributed to the variation of the coordinates of principle point. An approach for eliminating temperature-caused measurement error is finally proposed. Correlation models between camera parameters and temperature are formulated. Thereby, camera parameters under different temperature conditions can be predicted and the camera projective matrix can be updated accordingly. By reconstructing the world coordinates with the updated camera projective matrix, the temperature-caused measurement error is eliminated. A satisfactory performance has been achieved by the proposed approach in eliminating the temperature-caused measurement error.

Study on the Influence of Mixing Effect to the Measurement of Particle Size Distribution using DMA and CPC (혼합효과가 DMA와 CPC를 이용한 입자분포 측정에 미치는 영향에 관한 연구)

  • Lee, Youn-Soo;Ahn, Kang-Ho;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.326-333
    • /
    • 2003
  • In the measurement using DMA and CPC in series, there is some time delay for particles classified in DMA to detect in CPC. During this time, the DMA time-response changes due to the velocity profile of sampling tube and the diffusion of particles in the volume that exists between the DMA exit and the detector of ultra-fine CPC. This is called mixing effect. In the accelerated measurement methods like the TSI -SMPS, the size distribution is obtained from the correlation between the time-varying electrical potential of the DMA and the corresponding particle concentrations sampled in DMA. If the DMA time -response changes during this delay time, this can cause the error of a size distribution measured by this accelerated technique. The kernel function considering this mixing effect using the residence time distribution is proposed by Russell et al. In this study, we obtained a size distribution using this kernel to compare to the result obtained by the commercial accelerated measurement system, TSI -SMPS for verification and considered the errors that result from the mixing effect with the geometric mean diameters of originally sampled particles, using virtually calculated responses obtained with this kernel as input data.

Analysis of the Relative Effect of Rebar and Electrode Arrangement in the Measurement of Spparent Resistivity (겉보기 비저항 측정에서 철근과 전극배치의 상대적 영향 분석)

  • Lim, Young-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.317-318
    • /
    • 2021
  • The effect of reinforcing bars embedded in concrete varies depending on the position of the electrode in the electrical resistivity measurement. In this study, the apparent resistivity according to the electrode arrangement is analyzed for each measurement angle. Through this, it is intended to be used to improve the accuracy of measurement in the concrete resistivity.

  • PDF

Measurement of Reflection Coefficient of Sound Absorbent Material with Respect to Angle of Incidence and Its Associated Errors (입사각에 따른 흡음재의 반사 계수 측정 방법론 및 오차에 대한 고찰)

  • 이수열;김상렬;김양한
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.295-305
    • /
    • 1994
  • The reflection coefficient of a material at oblique incidence is measured in a free field. The sound pressure distributions are measured at discrete points on two measurement lines and then decomposed into plane wave components by using spatial Fourier transform. The inciedent and reflected plane wave components are obtained from a set of "decomposition equations" of which uses the plane wave propagation theory. Numerical simulations and experiments have been performed to see the effect of finite size of measurement area. To reduce this effect, a window fuction has been performed to see the effects of finite size of mesurement area. To reduce this effect, a window function has been proposed and its effect on the measurement of sound absorbing material property has been studied as well. The reflection coefficient obtained by this method is compared with those obtained from other methods; 2-microphone method in a duct and an expirical equation of which determines the characteristic impedance .rho.c and propagation constant k of a material from flow resistance information.formation.

  • PDF