• Title/Summary/Keyword: Edge Preserving

Search Result 152, Processing Time 0.022 seconds

A analysis of Thin-Straight Monopole antenna on a conducting box Using the Wire-Grid Method (Wire-Grid 방법을 이용한 도체 상자에 부착된 선형 모노폴 안테나 해석)

  • 이승엽;김경재;이영훈;허선종;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1669-1676
    • /
    • 1993
  • In this paper, a thin-straight monopole antenna attached to a conducting box is analyzed using a moment method with the pocklington integral expression for the exact Green's function. A modeling of a conducting box is based on a Wire-Grid method for an efficient calculation procedure. A system of linear equation is obtained using the piecewise sinusoidal basis function. And a Junction basis function is enforcing to represent the physical current on the edge of the conducting box. Especially, the junction basis functions are overlapped for the current continuity preserving on the vertexes. Numerical results are obtained for the current distribution on the unified antenna/conducting box system, input impedance and radiation pattern. The results are compared with the known data.

  • PDF

The characteristics of pseudomedian filter for De-interlacing scan conversion (De-interlacing scan coversion을 위한 pseudomedian filter의 특성)

  • 권병헌;김근배;황병원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1155-1171
    • /
    • 1996
  • In this paper, we have analized the characteristics of pseudomedian filter based on the preceding study. The proposed pseudomedian filter methods consist of two types, that are H-shaped and Asterisk-shaped window types. At first, the definition of pseudomedian filter and its algorithm for de-interlacing scan conversion have been descibed, especially its charateristics, this, is the edge preserving characteristics and the required computation have been compared with the conventional algorithms. And PSNR has been introduced to evaluate the pseudomedian filter methods and the conventional algorithms. Finally, it has been discussed on the features and trade off of the pseudomedian filter methods. And the merit and application fields of the pseudomedian filter methods have been discussed.

  • PDF

Depth Map Upsampling with Improved Sharpness (선명도를 향상시킨 깊이맵 업샘플링 방법)

  • Jang, Seungeun;Lee, Dongwoo;Kim, Sung-Yeol;Choi, Hwang Kyu;Kim, Manbae
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.933-944
    • /
    • 2012
  • In this paper, we propose a new method to convert a low-resolution depth map into its high-resolution one called distance transform-based bilateral upsampling. Since the proposed method controls the spatial domain weighting function based on distance transform values of the depth map, it increases the input depth map resolution while preserving edge sharpness. The proposed method is composed of three main steps: distance transform, spatial weighting control, and image interpolation. Experimental results show that our method outperforms the conventional bilateral upsampling in terms of the quality of output depth maps.

Image Deblocking Scheme for JPEG Compressed Images Using an Adaptive-Weighted Bilateral Filter

  • Wang, Liping;Wang, Chengyou;Huang, Wei;Zhou, Xiao
    • Journal of Information Processing Systems
    • /
    • v.12 no.4
    • /
    • pp.631-643
    • /
    • 2016
  • Due to the block-based discrete cosine transform (BDCT), JPEG compressed images usually exhibit blocking artifacts. When the bit rates are very low, blocking artifacts will seriously affect the image's visual quality. A bilateral filter has the features for edge-preserving when it smooths images, so we propose an adaptive-weighted bilateral filter based on the features. In this paper, an image-deblocking scheme using this kind of adaptive-weighted bilateral filter is proposed to remove and reduce blocking artifacts. Two parameters of the proposed adaptive-weighted bilateral filter are adaptive-weighted so that it can avoid over-blurring unsmooth regions while eliminating blocking artifacts in smooth regions. This is achieved in two aspects: by using local entropy to control the level of filtering of each single pixel point within the image, and by using an improved blind image quality assessment (BIQA) to control the strength of filtering different images whose blocking artifacts are different. It is proved by our experimental results that our proposed image-deblocking scheme provides good performance on eliminating blocking artifacts and can avoid the over-blurring of unsmooth regions.

Reduction of Quantum Noise using Adaptive Weighted Median filter in Medical Radio-Fluoroscoy Image (적응성 가중 메디안 필터를 이용한 의료용 X선 투시 영상의 양자잡음 제거)

  • Lee, Hoo-Min;Nam, Moon-Hyon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.10
    • /
    • pp.468-476
    • /
    • 2002
  • Digital images are easily corrupted by noise during the data transmission, data capture and data processing. A technical method of noise analyzing and adaptive filtering for reducing of quantum noise in medical radio-fluoroscopy images is presented. By adjusting the characteristics of the filter according to local statistics around each pixel of the image as moving windowing, it is possible to suppress noise sufficiently while preserve edge and other significant information required in diagnosis. We proposed adaptive weighed median(AWM) filters based on local statistics. We showed two ways of realizing the AWM filters. One is a simple type of AWM filter, which is constructed by Homogeneous factor(HF). Homogeneous factor(HF) from the noise models that enables the filter to recognize the local structures of the image is introduced, and an algorithm for determining the HF fitted to the diagnostic systems with various inner statistical properties is proposed. We show by the experimented that the performances of proposed method is superior to these of other filters and models in preserving small details and suppressing the noise at homogeneous region. The proposed algorithms were implemented by Visual C++ language on a IBM-PC Pentium 550 for testing purposes and the effects and results of the filter in the various levels of noise and images were proposed by comparing the values of NMSE(normalized mean square error) with the value of the other existing filtering methods.

A Study on Image Noise Reduction Technique for Low Light Level Environment (저조도 환경의 영상 잡음제거 기술에 관한 연구)

  • Lee, Ho-Cheol;Namgung, Jae-Chan;Lee, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.283-289
    • /
    • 2010
  • Recent advance of digital camera results in that image signal processing techniques are widely adopted to railroad security management. However, due to the nature of railroad management many images are acquired in low light level environment such as night scenes. The lack of light causes lots of noise in the image, which degrades image quality and causes errors in the next processes. 3D noise reducing techniques produce better results by using consecutive sequence of images. On the other hand, they cause degradation such as motion blur if there are motions in the sequence. In this paper, we use an adaptive weight filter to estimate more accurate motions and use the result of the adaptive filter to 3D result to improve objective and subjective mage quality.

Quantitative Evaluation of Sparse-view CT Images Obtained with Iterative Image Reconstruction Methods (반복적 연산으로 얻은 Sparse-view CT 영상에 대한 정량적 평가)

  • Kim, H.S.;Gao, Jie;Cho, M.H.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.257-263
    • /
    • 2011
  • Sparse-view CT imaging is considered to be a solution to reduce x-ray dose of CT. Sparse-view CT imaging may have severe streak artifacts that could compromise the image qualities. We have compared quality of sparseview images reconstructed with two representative iterative reconstruction techniques, SIRT and TV-minimization, in terms of image error and edge preservation. In the comparison study, we have used the Shepp-Logan phantom image and real CT images obtained with a micro-CT. In both phantom image and real CT image tests, TV-minimization technique shows the best performance in error reduction and preserving edges. However, the excessive computation time of TV-minimization is a technical challenge for the practical use.

Salt and Pepper Noise Removal Considering Directionality of Local Mask (국부 마스크의 방향성을 고려한 Salt and Pepper 잡음 제거)

  • Hong, Sang-Woo;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.676-678
    • /
    • 2016
  • Noise occurs in the process of obtaining, transmission, and processing in image processing systems and these noises lower the resolution of image and cause visual errors. Currently, a representative filter to remove salt and pepper noise is SMF(standard median filter) but it is inadequate in preserving edge as the noise field expands. Therefore, for salt and pepper noise enviroment, the study suggested and algorithm that are places with original pixel when the central pixel is non-noise and process by applying weighted value on areas with less local mask pixel changes when there is noise.

  • PDF

Performance Comparison of Ray-Driven System Models in Model-Based Iterative Reconstruction for Transmission Computed Tomography (투과 컴퓨터 단층촬영을 위한 모델 기반 반복연산 재구성에서 투사선 구동 시스템 모델의 성능 비교)

  • Jeong, J.E.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.142-150
    • /
    • 2014
  • The key to model-based iterative reconstruction (MBIR) algorithms for transmission computed tomography lies in the ability to accurately model the data formation process from the emitted photons produced in the transmission source to the measured photons at the detector. Therefore, accurately modeling the system matrix that accounts for the data formation process is a prerequisite for MBIR-based algorithms. In this work we compared quantitative performance of the three representative ray-driven methods for calculating the system matrix; the ray-tracing method (RTM), the distance-driven method (DDM), and the strip-area based method (SAM). We implemented the ordered-subsets separable surrogates (OS-SPS) algorithm using the three different models and performed simulation studies using a digital phantom. Our experimental results show that, in spite of the more advanced features in the SAM and DDM, the traditional RTM implemented in the OS-SPS algorithm with an edge-preserving regularizer out-performs the SAM and DDM in restoring complex edges in the underlying object. The performance of the RTM in smooth regions was also comparable to that of the SAM or DDM.

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.