• Title/Summary/Keyword: Eddy current type

Search Result 155, Processing Time 0.03 seconds

Characteristic Simulation of PM-Type Magnetic Circuit Breaker

  • Park, Han-Seok;Jung, Hong-Sub;Woo, Kyung-il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1279-1285
    • /
    • 2004
  • This paper presents the characteristic simulation of PM-type magnetic circuit breaker with the 2D finite element magnetic field solution including non-linearity of the material and an eddy current. Change of dynamic characteristic of the actuator is quantified from the finite element analysis. The results obtained from a commercial finite element analysis software are compared with those calculated from the developed finite element analysis software. A new modified model to decrease the eddy current is proposed. The characteristics of the two models are compared.

Analysis of Operating Characteristics of PM-Type Magnetic Circuit Breaker

  • Jun, Hee-Deuk;Woo, Kyung-Il;Kwon, Byung-Il
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.74-78
    • /
    • 2003
  • This paper describes the operating characteristic analysis of the PM-type linear oscillatory actuator used as a magnetic circuit breaker for the electromagnetic field, electric circuit, and mechanical motion problems. Transient calculations are based upon a 2D finite element magnetic field solution including non-linearity of materials. Changes of the dynamic characteristics from the eddy current in the plunger are quantified from finite element analysis. A new laminated model is proposed to decrease the eddy current effect.

Analysis of Mechanical Fixation Made of Aluminum Alloy in an Axial Flux Permanent Magnet Machine

  • Lee, Jiyoung;Park, Byounggung;Koo, Daehyun
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.309-313
    • /
    • 2014
  • This paper presents an eddy current loss analysis of a Mechanical Fixation (MF) made of 6061 aluminum alloy, which is used for an NS type double-rotor single-stator axial flux permanent magnet machine. The prototype MF made of aluminum alloy shows good mechanical performance, but poor electro-magnetic performance, since the machine's efficiency can decrease because of eddy current loss in the MF. In order to prevent efficiency decrease, a modification of the MF structure is also introduced. Three-dimensional finite element analysis (FEA) is used for magnetic field analysis, and eddy current losses are computed. The analysis results are compared to, and verified by the test results.

Development of an Eddy Current Type Magnetic Floor Hinge

  • Lee, Kapjin;Kim, Chulsoo;Park, Kyihwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.118.4-118
    • /
    • 2002
  • $\textbullet$ Magnetic floor hinge $\textbullet$ Recovering torque $\textbullet$ Eddy Currents $\textbullet$ Magnetic damper $\textbullet$ Optimal design $\textbullet$ Cost optimization

  • PDF

Extraction Method of Parameter of Self Excited Eddy Current Brake Using L-C Resonance and characteristic research (L-C 공진형 자여자 와전류 브레이크의 파라미터 추출 방법 및 특성연구)

  • Jeong, Taechul;Cho, Sooyoung;Ahn, Hanwoong;Jeong, Geochul;Park, Eung-Seok;Cho, Hyuntae;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.82-88
    • /
    • 2015
  • In recent years, numerous studies have attempted to find and explore the auxiliary brake and the oil pressure type and electrical type are mainly used. However, the model proposed here is to self-excited eddy current brake. The advantage of this is it does not require an external power supply and can be produced to reduce the size than others. This self-eddy current brake consists of RLC circuit so resistance, inductance and capacitance value can be considered a fixed value. But, inductance and resistance value changes depending on the shape, temperature and magnetic alteration. Therefore, in this paper, the focal point is characteristic analysis according to the parameter variations. Also, using this result, this paper explains how to estimate the capacitance.

Torque Analysis of Axial Flux PM Type Eddy Current Brake (영구자석형 와전류제동기의 토크 특성 해석)

  • Shin, Hyeon-Jae;Choi, Jang-Young;Cho, Han-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1019-1020
    • /
    • 2011
  • This paper deals with torque analysis of axial flux permanent magnet (AFPM) type eddy current brake (ECB) based on analytical field computation. On the basis of a magnetic vector potential and a two-dimensional (2-D) polar coordinate system, analytical solutions for normal and tangential flux density due to permanent magnet (PM) considering eddy current effect are obtained. And then, using derived analytical field solutions, braking torque and normal force characteristics according to rotor speed are also predicted. A three-dimensional (3-D) finite element (FE) analysis is employed to confirm the validity of analyses.

  • PDF

Linear Permanent Magnet Halbach Array Type Eddy Current Braker (선형 영구자석 Halbach 배열을 이용한 와전류 제동장치)

  • Jang, S.M.;Cha, S.D.;Jeong, S.S.;Ryu, D.W.;Park, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.855-857
    • /
    • 2000
  • Brake system using eddy current is adequate to obtain safe braking force in high speed transportation system and electric vehicle etc. In this paper, we propose the new type eddy current braker using Halbach array. which compared with the conventional permanent magnet array. The airgap flux density of Halbach array is higher 25% then conventional array, therefor we can predict that braking force is much large 1.56 times then conventional array.

  • PDF

Eddy Current Testing of Type-439 S/S Tube of MSR in Turbine System (터빈 습분분리재열기 Type-439 스테인리스강 튜브 와전류검사)

  • Lee, Heejong;Cho, Chanhee;Jung, Jeehong;Moon, Gyoonyoung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.50-56
    • /
    • 2008
  • The tubes in heat exchanger are typically made of copper alloy, stainless steel, carbon steel, titanium alloy material. Type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs) in turbine system. LP feedwater heaters generally utilize thin wall Type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the O.D(outside diameter) surface of Type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

  • PDF

Vibration of rotating machinery due to proximity (Proximity에서 유도된 회전기계의 이상 진동)

  • 구재량;황재현;김두영;윤완노;김연환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.532-535
    • /
    • 2003
  • Vibration of rotating machinery is a factor that is something to do with abnormal machinery. Former days, Perception of vibration at rotating machinery had used Shaft rider type. Shaft rider type was adhered to surface of shaft and detected vibration of rotating machinery. Recently, Perception of vibration at rotating machinery uses to non-contact sensor. Working principle of non-contact sensor is used of eddy current. Vibration at rotating machinery appears to deviation of eddy current. In this paper, We investigate abnormal vibration due to non-contact sensor.

  • PDF

Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline (연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발)

  • Kim, Young-Joo;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.187-192
    • /
    • 2002
  • The open-connect type eddy current transducer for the flaw detection in continuously connected pipelines was developed. This eddy current transducer is for the on-line inspection of the tubes in industries, to which commercial encircling probes are not applicable. The excitation coil that consists of a ribbon type cable and a flat connector can be opened and closed on purpose. The sensing coils of this transducer are circumferentially arrayed near the outside of the tube wall but axially displaced from the exciter by about one and half tube diameter. In application to steel tubes, and the performance of this transducer was evaluated as a little behind those of magnetic saturation type in signal to noise ratio and flaw size decision, but usable to detect or to locate large size flaws in steel tubes. Surface cracks deeper than 19% of the tube thickness could be detected with good signal to noise ratio.