• 제목/요약/키워드: Eddy covariance data

검색결과 63건 처리시간 0.022초

산림 사면에서 토양수분 실측 자료, 평형증발 및 에디-공분산방법을 이용한 토양증발비교 (Comparison of Soil Evaporation Using Equilibrium Evaporation, Eddy-Covariance and Surface Soil Moisture on the Forest Hillslope)

  • 곽용석;김상현;김수진
    • 한국환경과학회지
    • /
    • 제22권1호
    • /
    • pp.119-129
    • /
    • 2013
  • We compared equilibrium evaporation($E_{equili}$) eddy-covariance($E_{eddy}$) with soil moisture data($E_{SMseries}$) which were measured with a 2 hours sampling interval at three points for a humid forest hillslope from May 5th to May 31th in 2009. Accumulations of $E_{eddy}$, $E_{equili}$ for the study period were estimated as 2.52, 3.28 mm and those of $E_{SMseries}$ were ranged from 1.91 to 2.88 mm. It suggested that the eddy-covariance method considering the spatial heterogeneity of soil evaporation is useful to evaluate the soil evaporation. Method A, B and C were proposed using mean meterological data and daily moisture variation and the computations were compared to eddy-covariance method and equilibrium evaporation. The methods using soil moisture data can describe the variations of soil evaporation from eddy-covariance through simple moving average analysis. Method B showed a good matched with eddy-covariance method. This indicated that Dry Surface Layer (DSL) at 14:00 which was used for method B is important variable for the evaluation of soil evaporation. The total equilibrium evaporation was not significantly different to those of the others. However, equilibrium evaporation showed a problem in estimating soil evaporation because the temporal tendency of $E_{equili}$ was not related with the those of the other methods. The improved understanding of the soil evaporation presented in this study will contribute to the understandings of water cycles in a forest hillslope.

농림생태계와 대기간의 상호 작용 연구를 위한 에디 공분산 방법의 사용에 관하여 (On Using the Eddy Covariance Method to Study the Interaction between Agro-Forest Ecosystems and the Atmosphere)

  • 최태진;김준;윤진일
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.60-71
    • /
    • 1999
  • The micrometeorological tower flux network is the cornerstone of the global terrestrial vegetation monitoring. The eddy covariance technique used for tower fluxes is derived from the conservation of mass and is most applicable for steady-state conditions over flat, extended, and uniform vegetation. This technique allows us to obtain surface fluxes of energy budget components, greenhouse and trace gases, and other pollutants. The quality-controlled flux data are invaluable to validate various models with temporal scales ranging from minutes to years and spatial scales ranging from a few meters to hundreds of kilometers. In this paper, we review the theoretical background of this important eddy covariance technique, examine the measurement criteria and corrections, and finally suggest some measurement strategies that may facilitate coordinated flux measurements among different disciplines and provide a strong infrastructure for the global flux network.

  • PDF

남극 세종기지에서의 지표 플럭스 관측: I. 난류 특성과 현열 플럭스 (Surface Flux Measurements at King Sejong Station in West Antarctica: I. Turbulent Characteristics and Sensible Beat Flux)

  • 최태진;이방용;이희춘;심재설
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.453-463
    • /
    • 2004
  • The Antarctic Peninsula is important in terms of global warming research due to pronounced increase of air temperature over the last century. The first eddy covariance system was established at King Sejong Station located in the northern region of the Antarctic Peninsula in December of 2002 and has been operated over one year. Here, we analyze turbulent characteristics to determine quality control criteria for turbulent sensible heat flux data as well as to diagnose the possibility of long term eddy covariance measurement under extreme weather conditions of the Antarctic Peninsula. We also report the preliminary result on sensible heat flux. Based on the analyses on turbulent characteristics such as integral turbulence characteristics of vertical velocity (w) and heat (T), stationarity test and investigation of correlation coefficient, they fallow the Monin-Obukhov similarity and eddy covariance flux data were reliable. ${\sim}47%$ of total retrieved sensible heat flux data could be used for further analysis. Daytime averaged sensible heat flux showed a pronounced seasonal variation, with a maximum of up to $300Wm^{-2}$ in summer. In conclusion, continuous and long-term eddy covariance measurement may be possible at the study site and the land surface may influence the atmosphere significantly through heat transport in summer.

이어도해양과학기지에서의 에디 공분산 방법을 이용한 플럭스 관측 (Tower-based Flux Measurement Using the Eddy Covariance Method at Ieodo Ocean Research Station)

  • 이희춘;이방용;김준;심재설
    • Ocean and Polar Research
    • /
    • 제26권2호
    • /
    • pp.145-154
    • /
    • 2004
  • Surface energy and $CO_2$ fluxes have been measured over an ocean at Ieodo Ocean Research Station of KORDI since May 2003. Eddy covariance technique, which is a direct flux measurement, is used to quantitatively understand the interaction between the ocean surface and the atmospheric boundary layer. Although fluxes were continuously measured during the period from May 2003 to February 2004, the quality control of these data yielded <20% of data retrieval. The atmospheric stability did not show any distinct dirunal patterns and remained near-neutral to stable from May to June but mostly unstable during fall and winter in 2003. Sensible heat flux showed a good correlation with the difference between the sea water temperature and the air temperature. The maximum fluxes of sensible heat and latent heat were $120Wm^{-2}$ and $350Wm^{-2}$ respectively, with an averaged Bowen ratio of 0.2. The ocean around the tower absorbed $CO_2$ from the atmosphere and the uptake rates showed seasonal variations. Based our preliminary results, the daytime $CO_2$ flux was steady with an average of $-0.1 mgCO_2m^{-2}s^{-1}$ in summer and increased in winter. The nighttime $CO_2$ uptake was greater and fluctuating, reaching up to $-0.1 mgCO_2m^{-2}s^{-1}$ but these data require further examination due to weak turbulent mixing at nighttime. The magnitude of $CO_2$ flux was positively correlated with the half hourly changes in horizontal mean wind speed. Due to the paucity of quality data, further data collection is needed for more detailed analyses and interpretation.

낙동강 유역에서 관측된 에디 공분산 자료의 품질 관리 및 플럭스 특성 (Quality Control and Characteristic of Eddy Covariance Data in the Region of Nakdong River)

  • 이영희;이병주;강금아;김수진;홍선옥
    • 대기
    • /
    • 제23권3호
    • /
    • pp.307-320
    • /
    • 2013
  • We performed comprehensive quality control for eddy-covariance measurements from 3 farmland sites and 1 industrial site adjacent to Nakdong river. The quality control program is based on Foken and Wichura (1996) and Vicker and Mahrt (1997) and we added criteria for trend and standard deviation for scalar variables and modified criteria for non-stationarity condition of Foken and Wichura (1996) to consider random error of fluxes. The classification of data quality is designed for the raw data and the processed flux data, separately. Use of added criteria efficiently reduces the number of outlier for water vapor and $CO_2$ fluxes and use of modified criteria for non-stationarity reduces the number of outlier for scalar fluxes and increases the number of data with accepted quality for further work. Energy balance ratio is higher in farmlands than industrial site, which is due to neglect of heat storage term in industrial site. Among farmland sites, C4 site shows higher energy balance ratio than other sites. This is due to more homogeneous surface of C4 site than other farmland sites. However, energy balance ratio is very low or even negative at night. Mismatch between the flux footprint and the other energy component footprint over the heterogeneous surface is main cause for energy imbalance at night. Other possible causes are also discussed.

태국 Tak 플럭스 관측소의 실시간 자료 감시 및 모사 시스템 (Real Time Monitoring and Simulation System (RTMASS) for Tak Flux Measurement Site, Thailand)

  • Wonsik Kim;Hyungjun Kim;Joon Kim;Yasushi Agata;Shin Miyazaki;Taikan Oki
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.116-127
    • /
    • 2003
  • 태국 북서부의 Tak 지방에 KoFlux(Korean Flux Network) 연구의 일환으로서 플럭스 관측소(Tak flux measurement, TFM site)가 설립되었다. 이곳에서 이산화탄소와 물, 그리고 에너지 플럭스를 관측하기 위해 와 공분산시스템(eddy covariance system)을 적용하였으며 관측된 자료는 실시간 자료 감시 및 모사 시스템(Real time monitoring and simulation system, RTMASS)을 이용하여 처리되어 전송된다. RTMASS는 KoFlux-DIS(Data information system)의 핵심 구조이고 원격지 시스템과 중앙 시스템으로 나누어지며 자료의 수집 및 전송. 자료의 저장 및 처리가 본 시스템의 주된 기능이다. 난류특성과 미기상학적인 분석 자료에 따르면, TM 관측소는 열대 낙엽수림에 대한 다양한 플럭스 및 에너지 수지를 관측하고 분석하는데 적합하다고 할 수 있다.

주간에 두 타워로부터 관측된 에디 공분산 자료의 확률 오차의 추정 (Estimation of the Random Error of Eddy Covariance Data from Two Towers during Daytime)

  • 임희정;이영희;조창범;김규랑;김백조
    • 대기
    • /
    • 제26권3호
    • /
    • pp.483-492
    • /
    • 2016
  • We have examined the random error of eddy covariance (EC) measurements on the basis of two-tower approach during daytime. Two EC towers were placed on the grassland with different vegetation density near Gumi-weir. We calculated the random error using three different methods. The first method (M1) is two-tower method suggested by Hollinger and Richardson (2005) where random error is based on differences between simultaneous flux measurements from two towers in very similar environmental conditions. The second one (M2) is suggested by Kessomkiat et al. (2013), which is extended procedure to estimate random error of EC data for two towers in more heterogeneous environmental conditions. They removed systematic flux difference due to the energy balance deficit and evaporative fraction difference between two sites before determining the random error of fluxes using M1 method. Here, we introduce the third method (M3) where we additionally removed systematic flux difference due to available energy difference between two sites. Compared to M1 and M2 methods, application of M3 method results in more symmetric random error distribution. The magnitude of estimated random error is smallest when using M3 method because application of M3 method results in the least systematic flux difference between two sites among three methods. An empirical formula of random error is developed as a function of flux magnitude, wind speed and measurement height for use in single tower sites near Nakdong River. This study suggests that correcting available energy difference between two sites is also required for calculating the random error of EC data from two towers at heterogeneous site where vegetation density is low.

KoFlux 관측지에서 에디 공분산 자료의 품질관리 및 보증 (Quality Control and Assurance of Eddy Covariance Data at the Two KoFlux Sites)

  • 권효정;박성빈;강민석;유재일;렌민 유안;김준
    • 한국농림기상학회지
    • /
    • 제9권4호
    • /
    • pp.260-267
    • /
    • 2007
  • 이 연구노트에서는 KoFlux 관측지인 광릉 산림과 해남 농경지에서 관측된 에디 공분산 자료의 품질을 관리하고 보증하는 방법을 소개하였다. 자료의 품질 관리는 미기상학적/통계학적 분석을 기반으로 8 단계의 과정을 거쳐 이루어졌고 자료의 품질에 따라 5 등급으로 분리되어 표시되었다. 품질관리를 위해 사용된 프로그램과 품질 보증된 최종 자료는 KoFlux 웹사이트(http://www.koflux.org/)에서 내려 받을 수 있다.

경사가 있는 지형의 거칠기 아층에서 풍향시어와 운동량 플럭스의 특성 (Characteristics of Wind Direction Shear and Momentum Fluxes within Roughness Sublayer over Sloping Terrain)

  • 이영희
    • 대기
    • /
    • 제25권4호
    • /
    • pp.591-600
    • /
    • 2015
  • We have analyzed wind and eddy covariance data collected within roughness sublayer over sloping terrain. The study site is located on non-flat terrain with slopes in both south-north and east-west directions. The surface elevation change is smaller than the height of roughness element such as building and tree. This study examines the directional wind shear for data collected at three levels in the lowest 10 m in the roughness sublayer. The wind direction shear is caused by drag of roughness element and terrain-induced motions at this site. Small directional shear occurs when wind speed at 10 m is strong and wind direction at 10 m is southerly which is the same direction as upslope flow near surface at this site during daytime. Correlation between vertical shear of lateral momentum and lateral momentum flux is smaller over steeply sloped surface compared to mildly sloped surface and lateral momentum flux is not down-gradient over steeply sloped surface. Quadrant analysis shows that the relative contribution of four quadrants to momentum flux depends on both surface slope and wind direction shear.

개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정 (Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy)

  • 강남구;윤주열;아산 탈룩더;문민규;강민석;심교문;김준
    • 한국농림기상학회지
    • /
    • 제17권1호
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$$CO_2$$N_2O$와 더불어 중요한 온실가스로서 지속적이고도 체계적인 감시가 요구된다. 에디 공분산 기술 기반의 $CO_2$ 플럭스의 관측은 이미 세계적으로 관측망이 구축되어 관측부터 자료처리에 이르기까지 모든 과정이 표준화되어 있을 뿐 아니라 체계적으로 잘 문서화되어 있다. 그러나 미량 기체인 $CH_4$의 경우, 레이저 기반의 고속반응 분광계를 필요로 할 뿐 아니라, 이에 수반되는 플럭스 자료의 처리 과정이 표준화되어 있지 않다. 본 연구 노트에서는 최근에 상용화된 개회로 파장 변조 분광계를 사용하여 에디 공분산 방법으로 논에서 관측한 $CH_4$ 플럭스 결과를 보고하였다. 모내기 전과 직후의 각 5일간 연속 관측한 자료를 KoFlux 프로토콜에 따라 상용화된 $EddyPro^{TM}$ 프로그램을 사용하여 자료를 처리하였다. 이 후처리 과정에서 세 가지 주요 보정, (1) 주파수 반응 보정, (2) 공기 밀도 보정, (3) 분광 보정의 효과를 정량화 하였다. 보정 효과는 밤과 낮에 따라 차이를 보였고, 메탄플럭스가 작을수록 보정 효과가 컸다. 전반적으로 보정 후에 메탄 플럭스는 평균 20-25% 정도 증가하였다. 국가농림기상센터(www.ncam.kr)에서는 분광 보정과 빈 자료 메우기를 포함한 $CH_4$플럭스 자료 처리가 포함된 업데이트된 KoFlux 프로그램을 일반 사용자에게 제공할 예정이다.