Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.

Design of a Shielded Reflection Type Pulsed Eddy Current Probe for the Evaluation of Thickness (두께 평가를 위한 차폐된 반사형 펄스 와전류 탐촉자의 설계)

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.398-408
    • /
    • 2007
  • For better evaluation of material thickness by using the reflection type pulsed eddy current method, various probe models are designed and their response signals, characteristics, and sensitivities to thickness variation are investigated by a numerical analysis method. Since the sensor needs to detect magnetic fields from eddy currents induced in a test material, not from the exciter coil, two types of models that are shielded by the combination of copper and ferrite and only by ferrite are considered. By studying response signals from these shielded probe models, the peak value and the zero crossing time are selected as useful signal features for the evaluation of material thickness. Investigation of sensitivities of these two features shows that the sensitivity of peak value is more useful than that of zero crossing time and that the probe shielded only by ferrite gives much better sensitivity to thickness variation.

Comparison of Absolute and Differential ECT Signals around Tube Support Plate in Steam Generator

  • Shin, Young-Kil;Lee, Yun-Tai;Song, Myung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.201-208
    • /
    • 2005
  • In this paper, absolute and differential eddy current signals from various defects in the steam generator tube are numerically predicted and their signal slope characteristics are investigated. The signal changes due to frequency increase are also observed. After studying signal patterns from various defects and frequencies, the analysis of mixed defect signals affected by the presence of a ferromagnetic support plate is attempted. For the signal prediction, axisymmetric finite element modeling is used and this leads us to the slope angle analysis of the signal. Results show that differential signals are useful for locating the position of a defect under the support plate, while absolute signals are easy to presume and interpret even though the effect of support plate is mixed. Combined use of these two types of signals will help us accomplish a more reliable inspection.

Analysis of Bobbin Probe Signal in Steam Generator Tube with Bulge Defect (증기발생기 세관의 Bulge결함에 대한 보빈프로브 신호해석)

  • Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.702-704
    • /
    • 2003
  • In this paper, analysis of bobbin probe signal in steam generator tube with bulge defect on CE system 80 nuclear power plant is represented. The CE system 80 steam generator is adopted in ULJIN-4 nuclear power plant. From Maxwell's equation, the electromagnetic governing equation for eddy current problem is derived and by performing the finite element formulation the 3-dimensional finite element code with brick element is developed. For the ease of the comparison the numerical results with experimental ones, the calculated signals are adjusted by using the ASME standard 100[%] through hole signal. For analysis of the effect of variation of the bulge depth on the impedance signal 0.2[mm] and 0.4[mm] depth of bulge defect signals are calculated and analyzed. As the depth of the bulge defect is increased, the magnitude of the signal is increased, too. But the rate of the increment of the signal is less than that of the depth of defect. From the result of this paper, we can obtained the information of the effect of bulge defect on the impedance signal.

  • PDF

An intelligent eddy current signal evaluation system to automate the non-destructive testing of steam generator tubes in nuclear power plant

  • Kang, Soon-Ju;Ryu, Chan-Ho;Choi, In-Seon;Kim, Young-Ill;Kim, kill-Yoo;Hur, Young-Hwan;Choi, Seong-Soo;Choi, Baeng-Jae;Woo, Hee-Gon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.74-78
    • /
    • 1992
  • This paper describes an intelligent system to automatic evaluation of eddy current(EC) signal for Inspection of steam generator(SG) tubes in nuclear power plant. Some features of the intelligent system design in the proposed system are : (1) separation of representation scheme ,or event capturing knowledge in EC signal and for structural inspection knowledge in SG tubes inspection; (2) each representation scheme is implemented in different methods, one is syntactic pattern grammar and the other is rule based production. This intelligent system also includes an data base system and an user interface system to support integration of the hybrid knowledge processing methods. The intelligent system based on the proposed concept is useful in simplifying the knowledge elicitation process of the rule based production system, and in increasing the performance in real time signal inspection application.

  • PDF

Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

  • Hwang, S.M.;Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, K.;Lee, S.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.20-23
    • /
    • 2013
  • For sensitive measurements of micro-Tesla nuclear magnetic resonance (${\mu}T$-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 $fT/{\surd}Hz$, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise ${\mu}T$-NMR experiments.

Eddy Current and Ultrasonic IRIS Signal Characteristics of Reboiler Tube by Using STS 316L Calibration Specimen (STS 316L 교정시험편을 이용한 재가열기 튜브의 와전류신호와 초음파 IRIS 신호 특성)

  • Tak, Kyeong-Joo;Kim, Byung-Il;Gook, Jin-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.56-63
    • /
    • 2012
  • In this study, a field applicability of reboiler tube was evaluated by comparing ECT signal with IRIS signal about wall loss rate and remaining wall thickness using worked austenite STS 316L ASME standard calibration tube. In the case of wall-loss rate, as a result, tolerance about $20%{\times}4$ flat bottom hole and 10% O D groove(ECT), 80% defect and 10% O D groove(IRIS) occurred up to ${\pm}15%$. In the case of remaining wall thickness, ECT was satisfied with the both tolerance, but tolerance about 80% defect occurred up to ${\pm}15%$ in IRIS. Therefore, if the IRIS is performed for interpretation of non-relevant indication and measurement of wall-loss rate after ECT, reliability is supposed to be improved.

GMR Sensor Applicability to Remote Field Eddy Current Defect Signal Detection in a Ferromagnetic Pipe (강자성 배관의 원격장 와전류 결함 신호 검출에 GMR Sensor의 적용성 연구)

  • Park, Jeong Won;Park, Jae Ha;Song, Sung Jin;Kim, Hak Joon;Kwon, Se Gon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.483-489
    • /
    • 2016
  • The typical methods used for inspecting ferromagnetic pipes include the ultrasonic testing (UT) contact method and the following non-contact methods: magnetic flux leakage (MFL), electromagnetic acoustic transducers (EMAT), and remote field eddy current testing (RFECT). Among these methods, the RFECT method has the advantage of being able to establish a system smaller than the diameter of a pipe. However, the method has several disadvantages as well, including different sensitivities and difficult-to-repair coil sensors which comprise its array system. Therefore, a giant magneto-resistance (GMR) sensor was applied to address these issues. The GMR sensor is small, easy to replace, and has uniform sensitivity. In this experiment, the GMR sensor was used to measure remote field and defect signal characteristics (in the axial and radial directions) in a ferromagnetic pipe. These characteristics were measured in an effort to investigate standard defects at changing depths within a pipe. The results show that the experiment successfully demonstrated the applicability of the GMR sensor to RFECT signal detection in ferromagnetic pipe.

Prediction and Analysis of Bobbin ECT Signals generated by Tube Defects near Support Plate (지지대 부근의 전열관 결함으로 인해 발생되는 보빈 와전류신호의 예측 및 분석)

  • Shin, Young-Kil;Lee, Yun-Tai
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.942-944
    • /
    • 2005
  • In this study, eddy current signals from various anomalous defects in the heat exchanger tube are predicted af their signal slope characteristics no analyzed. The signal changes due to frequency increase are also observed. Based in the accumulated knowledge, the analysis of superimposed signal is attempted which includes the effects of support plate. Both differential and absolute bobbin probe signals are analyzed. For the prediction of signals, axisymmetric finite element modeling is used and this leads us to the utilization of slope angle analysis of the signal. Results show that differential signals are useful to locate the position of defect under the support plate and absolute signals no easy to predict and analyze even though they no superimposed signals. Combined use of these two types of signals will accomplish a reliable inspection.

  • PDF

Finite Element Analysis of Eddy Current Testing for Tubes with 3-Dimensional Defects (3차원 관결함에 대한 와전류탐상의 유한요소해석)

  • Lee, Hyang-Beom;Won, Sung-Yean;Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.191-199
    • /
    • 2000
  • In this paper, a numerical analysis using the finite element method (FEM) is presented which models the eddy current testing (ECT) of tubes with 3-dimensional defects. For the description of 3-dimensional eddy current problems, the governing equation is derived from the Maxwell's equations. The 3-dimensional FEM formulation with hexahedral elements is carried out using the Galerkin weighted residual method. The INCONEL 600 steam generator tube with inner and outer diameter defects is adopted for the numerical analysis, and the ECT signal, which is the trajectory of the probe impedance, is calculated. For the verification of the numerical analysis method, results of numerical calculations and experiments are compared and they show good agreements. Based on this verification, several defect signals are predicted and their characteristics are investigated with the variation in the defect depth and the circumferential angle of the defect.

  • PDF