• 제목/요약/키워드: Ecological simulation

검색결과 343건 처리시간 0.032초

지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구 (Feasibility study of ground source heat pump system according to the local climate condition)

  • 남유진
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.127-131
    • /
    • 2014
  • The ground source heat pump (GSHP) system is a kind of the temperature differential energy system using relatively stable underground temperature as heat source of space heating and cooling. This system can achieve higher performance of system than it of conventional air source heat pump systems. However, its superiority of the system performance is different according to installation location or local climate, because the system performance depends on the underground condition which is decided by annual average air temperature. In this study, in order to estimate the feasibility of the ground source heat pump system according to the local climate, numerical simulation was conducted using the ground heat transfer model and the surface heat balance model. The case study was conducted in the condition of Seoul, Daejeon, and Busan, In the result, the heat exchange rate of Busan was 34.33 W/m as the largest in heating season and it of Seoul was 40.61 W/m as the largest in cooling.

Energy Performance and Improvement in University Library - Concentrated on 'K'University Library located in Seojong City -

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.47-52
    • /
    • 2014
  • The problem of energy consumption is more serious in university buildings than primary, middle and high school buildings. Because university buildings have generally heating and cooling systems, and various incidental facilities. In university, the library is one of the building that many people use and the most energy is spent. So, investigation on energy saving is very important and urgent. This study aims finally to present the guideline for low-energy design of University library by aiding a designer to select best solution in the side of energy-saving. In this paper, composition of space, utilization schedule and performance of construction materials are grasped, some primary factors that effect to energy saving are analyzed by energy simulation. The result of this study is as follows; First, the subject library has more cooling load than heating load because of cooling load generated during middle season. Second, green roofs is the most effective to heating load saving, but not to cooling energy. Third, outdoor air cooling is the most effective to cooling energy saving among the investigated strategies included in this study.

Gap 모델을 이용한 광릉삼림군락의 천이에 대한 모의 실험 (Simulation of Forest Succession in Kwangnung Experimental Forest with Gap Model)

  • Han, You-Young;Park, Seung-Tai;Kim, Joon-Ho;Lee, Chang-Seok
    • The Korean Journal of Ecology
    • /
    • 제19권6호
    • /
    • pp.499-506
    • /
    • 1996
  • Forest stand development in Kwangnung Experimental Forest, Korea, was simulated with a forest succession gap model of the JABOWA/FORET type, in order to predict climax species and characterime the trend of community structure along the succession. The model runs for a period or 1, 000 yr and is based on the averaged successional characteristics of 50 forest plote with an individual size or 1/12 ha gap consisted of the 15 major tree species. The total bimass and leafarea index have arrived at a steady state since about 200 yr and these values are smaller than that or field survey. Carpinus cordata, C. laxiflora, Quercus mongolica and Q. serrata were epected to be climax species that represent about 86% or total biomass in later stage and these results coincided with the previous succession studies from field survey in the area.

  • PDF

발코니 거치 태양광 발전장치의 구조적 안전성에 관한 연구 (A Study on the Structural Safety of Photovoltaic System Mounted on Balcony Railing)

  • 조정제;정유근
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.33-38
    • /
    • 2012
  • This study aims to evaluate the structural safety of the balcony photovoltaic systems easily installed or moved on the buildings. Also, the systems are controlled by solar altitudes focused on its mobility rather than high efficiency generation performance thereof. The results of the study are as follows. Two types of typical photovoltaic systems which can be mounted on the balcony are proposed, and, the sizes of the systems are designed to be adjusted within certain ranges of the frames in order to attach the various rail sizes. To evaluate the structural safety of the proposed systems, several simulation evaluations are performed on the safety evaluation standards by the Ministry of Construction-Transportation and KCI 2007. The results are that the proposed plans are reasonable in terms of stress and deflection in the structural aspects at the wind pressures of $1,907(N/m^2)$ of external wall surface under the condition of wind velocity higher than 25(m/s).

Analysis for Energy Efficiency of the Algae Façade - Focused on Closed Bioreactor System -

  • Kim, Tae-Ryong;Han, Seung-Hoon
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.15-21
    • /
    • 2014
  • Recently, energy generation using algae technology is being promising due to the emerging issues on energy insufficiency and environmental contamination, although the solution has not been resolved in aspect of technological and economical efficiencies since it was originally proposed in the early 1980s by many scholars. The energy production technology using algae materials has great values as not only a solution for new energy generation but also an eco-friendly sustainable building equipment system. In addition, cultivation tank for algae using water sources seems to play a role as a decreasing system for thermal transmittance on building components. This study aims at investigating the adaptability towards the future sustainable building with algae technology and testifying the energy efficiency of the algae skins by operating a couple of simulation tools to measure building performances for the proposed prototype of the façade system.

자연환기 시스템을 이용한 고층 공동주택의 환기성능 향상에 관한 연구 (A Study on Improving Ventilation Performance in High-rise Residential Building by Natural Ventilation System)

  • 최태환;김유미;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2007
  • This study focuses on developing natural ventilation system which is able to satisfy the good indoor air quality and air speed. The natural ventilation system developed in this study is for double window façade and it has two operation modes for summer and winter. Operational sections of the devices have been analyzed by CFD simulation to calculate discharge coefficients of openings and estimated indoor air speed. For the analysis of the appropriate installation area ratio for each room and the optimum installation area, TRNFLOW simulation has been used. As the results, we could see that the natural ventilation system can provide the similar pollutant removal performance to 0.7 ACH of mechanical ventilation with appropriate installation area and installation area ratio.

투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구 (A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building)

  • 임상준;서혜수;김병선
    • KIEAE Journal
    • /
    • 제2권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

시스템 다이내믹스를 활용한 친환경건축물 인증기준의 동태모형 개발에 관한 연구 (Dynamic Modeling of Green Building Certification Criteria Using System Dynamics)

  • 최우람;이효원
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.53-61
    • /
    • 2009
  • Green Building Certification System currently going into effect is a static evaluation model. Therefore, as far as the sustainable development of certification system is concerned, further long-term evaluation is required. The main purpose of this study is to offer a model in a way of developing and verifying a dynamic model in Green Building Certification. A dynamic model development has been given System Dynamics based on the causal structure. Thus, this study focused on searching the causal structure of certification criteria and verifying the reality of the model through simulation processing after developing a model. In conclusion, the development of dynamic evaluation method can be attributed to systematic evaluation for the criteria of Certification System.

CFD해석에 의한 침실 호흡역의 환기효율 분석 (Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room)

  • 유복희;윤정숙
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

인접도로의 유형에 따른 공동주택 주거단지의 도로교통소음 전달영향 및 평가 (A Study on the Prediction and Evaluation of Road Traffic Noise at the Apartment Housing Complex depending on the Types of Adjacent Roads)

  • 백건종;장길수;백은선
    • KIEAE Journal
    • /
    • 제9권1호
    • /
    • pp.61-68
    • /
    • 2009
  • In this study, computer simulation program was using to identify the effects of road traffic noise propagation depending on the road types which are very variable in dense city. To achieve this goal, the roads should adjacent to housing complex were categorized into 7 types and propagation noise level should predicted then after simulation of noise exposure population calculation are carried out. Followings the results. First, the road types producing the higher noise level are R1, R2, R3 and R7. The lowest one is R6. And R4, R5 showed that some amount of noise level reduction. Second. the R6 road type which is tunnel shaped showed the highest noise level reduction in vertical distance gap. Last, the order of noise exposure population ratio is R1>R2>R7 and R6 showed the lowest.