• 제목/요약/키워드: Echo Image

검색결과 262건 처리시간 0.026초

고등어(Scomber japonicus), 불볼락(Sebastes thompsoni) 및 쥐노래미(Hexagrammos otakii)에 의한 광대역 음향산란신호의 시간-주파수 분석 (Time-Frequency Analysis of Broadband Acoustic Scattering from Chub Mackerel Scomber japonicus, Goldeye Rockfish Sebastes thompsoni, and Fat Greenling Hexagrammos otakii)

  • 이대재
    • 한국수산과학회지
    • /
    • 제48권2호
    • /
    • pp.221-232
    • /
    • 2015
  • Broadband echoes measured in live chub mackerel Scomber japonicus, goldeye rockfish Sebastes thompsoni, and fat greenling Hexagrammos otakii with different morphologies and internal characteristics were analyzed in time and frequency domains to understand the species-specific echo feature characteristics for classifying fish species. The mean echo image for each time-frequency representation dataset obtained as a function of orientation angle was extracted to mitigate the effect of fish orientation on acoustic scattering. The joint time-frequency content of the broadband echo signals was obtained using the smoothed pseudo-Wigner-Ville distribution (SPWVD). The SPWVDs were analyzed for each echo signature of the three fish species. The results show that the time-frequency analysis provided species-specific echo structure patterns and metrics of the broadband acoustic signals to facilitate fish species classification.

자기공명 확산강조영상검사 시 영상왜곡 감소에 관한 연구 (The Study on Reduction of Image Distortion by using Single-Shot Turbo Spin Echo in Brain Stem Diffusion MRI)

  • 최관우;이호범;나사라;유병규;손순룡
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.279-284
    • /
    • 2016
  • 본 연구는 DWI 검사 시 자화율 차이로 인해 뇌줄기에 발생하는 영상의 왜곡을 새로운 SS-TSE를 적용하여 감소시키고자 하였다. 연구방법은 2015년 7월부터 동년 9월까지 DWI 검사를 검사한 30명을 대상으로, 기존의 SS-EPI 기법과 새로운 SS-TSE를 적용하여 기법에 따른 뇌줄기의 왜곡과 오차율을 비교평가 하였다. 연구결과, 새로운 SS-TSE 적용 시 왜곡이 감소된 것을 볼 수 있으며, 오차율 또한 b0 영상은 2.4%(11.1%에서 8.7%), b1000 영상은 1.2%(11.4%에서 10.1%) 감소하는 것을 볼 수 있었다. 결론적으로, 뇌줄기의 DWI 검사 시 본 연구의 SS-TSE를 이용하면 기존 기법 사용 시 발생하는 영상의 왜곡을 감소시킬 수 있어 진단적 가치가 높은 영상을 획득할 수 있다.

실내 환경에서 Chirp Emission과 Echo Signal을 이용한 심층신경망 기반 객체 감지 기법 (DECODE: A Novel Method of DEep CNN-based Object DEtection using Chirps Emission and Echo Signals in Indoor Environment)

  • 남현수;정종필
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권3호
    • /
    • pp.59-66
    • /
    • 2021
  • 인간은 오감 (시각, 청각, 후각, 촉각, 미각) 중 시각 및 청각 정보를 위주로 사용하여 주변 물체를 인식한다. 최신의 객체 인식과 관련한 주요 연구에서는 주로 이미지센서 정보를 이용한 분석에 초점이 맞추어져 있다. 본 논문에서는 다양한 chirp 오디오 신호를 관측공간에 방출하고 2채널 수신센서를 통해 echo를 수집하여 스펙트럼 이미지로 변화시킨 후 딥러닝을 기반으로 이미지 학습 알고리즘을 이용하여 3D 공간상의 객체 인식 실험을 진행하였다. 본 실험은 무향실의 이상적 조건이 아닌 일반적인 실내 환경에서 발생하는 잡음 및 echo가 있는 환경에서 실험을 진행하였고 echo를 통해 객체 인식률을 83% 정확도로 물체의 위치 추정할 수 있었다. 또 한 추론 결과를 관측공간과 3D Sound 공간 신호로 mapping 하여 소리로 출력하여 3D 사운드의 학습을 통해 소리를 통한 시각 정보를 얻을 수 있었다. 이는 객체 인식 연구를 위해서 이미지 정보와 함께 다양한 echo 정보의 활용이 요구된다는 의미이며 이런 기술을 3D 사운드를 통한 증강현실 등에 활용 가능할 것이다.

2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정 (Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images)

  • Yoo, Done-Sik
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.33-40
    • /
    • 1999
  • 목적 : 본 논문은 2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기를 계산하고 측정값과 비교 분석하는 데 목적을 두었다. 대상 및 방법 : 신경계 양성자 강조영상은 뼈를 제외한 뇌척수액과 근육 및 지방 등 모든 조직을 보여준다. 또한 자기공명영상을 이용하면 2차원이나 3차원 영상을 얻을 수 있다. 본 연구에서는 2차원 영상기법으로 2차원 고속스핀반향 (Fast spin-echo) 영상법을 사용하였고 3 차원 영상기법으로는 3차원 경사자계반향(Gradient-echo) 영상법을 사용하였다. 2차원 스핀반향 (Spin-echo)과 3차원 경사자계반향 영상법에 나타난 뇌척수액과 근육 및 지방의 신호세기를 알아내기 위해 2차원 스핀 반향과 3차원 경사자계반향의 신호세기의 이론값을 계산하였다. 2차원 고속스핀반향 영상법에서는 양성자 강조영상을 얻기 위해 긴 반복시간 (4000 ms) 과 짧은 반향시간(TE$_{eff}$ =22 ms)을 적용하였다. 3차원 경사자계반향 영상법에서는 양성자 강조영상을 얻기 위해 작은 꺽임각 (8$^{\circ}$) 과 짧은 반복시간 (35 ms) 및 짧은 반향시간 (3 ms)을 적용하였다. 결과: 2차원 고속스핀반향 영상법에서는 뇌척수액과 근육 및 지방의 영상 대조도가 우수하였고 신호 대 잡음비(SNR) 값은 39-57 사이였다. 3차원 경사자계반향 영상법에 나타난 뇌척수액과 근육 및 지방의 영상 대조도는 2차원 고속스핀반향 영상법의 결과와 비슷하였지만 신호 대 잡음비(SNR) 값은 26-33 사이였다. 신호 대 잡음비는 2차원 고속스핀반향 영상법이 3차원 경사자계반향 영상 법보다 높았고 가장자리 향상효과 때문에 2차원 고속스핀반향 영상에서 머리뼈의 가장자리를 쉽게 구별할 수 있었다. 덧붙여 2차원 고속스핀반향 영상에 나타난 뇌척수액과 근육 및 지방 사이의 대조도는 강한 신호세기와 향상된 뇌척수액의 가장자리 때문에 상당히 우수하였다. 결론 : 2차원과 3차원 신경계 자기공명영상에서 머리뼈 주위에 있는 여러 조직의 신호세기를 계산하고 측정값과 비교 분석하였다. 뇌척수액과 근육 및 지방의 계산값과 측정값의 영상 대조도와 신호 대 잡음비 값이 2차원 고속스핀반향 영상법과 3차원 경사자계반향 영상법에서 대체로 일치하였다. 그렇지만 2차원 고속스핀반향 영상에서 뇌척수액과 근육 및 지방 사이의 대조도가 우수하였고 신호 대 잡음비는 상대적으로 높았으며 상대적으로 짧은 영상시간이 소요되었다.

  • PDF

음향 반향 제거기의 수렴속도 개선에 대한 연구 (Study on Improvement of Convergence Rate of Acoustic Echo Canceller)

  • 강희훈
    • 한국전자통신학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-69
    • /
    • 2009
  • 적응형 반향제거기는 스피커폰, 3G 화상전화와 VoIP 서비스 시스템과 같은 응용분야에 필수적인 요소이다. 일반적인 반향제거기들은 반향을 제거하기 위해서 매우 많은 탭을 필요한다. 이들 탭수의 증가는 계산량을 증가시키고 수렴속도를 떨어뜨리는 원인이 된다. 이러한 단점들을 극복하기 위해서, 본 논문에서는 수렴속도를 개선할 수 있는 적응형 반향제거기를 제안한다. 본 논문에서 수렴속도를 개선하기 위해서 반향대역을 부대역으로 구분하고 각 부대역에 적용형 필터링을 적용한다. 각 부대역 필터는 부대역 반향 신호로써 반향신호를 인식하게 되고 따라서 동적인 부대역이 적게 되어 수렴속도를 빠르게 한다. 게다가 탭수와 가중치 갱신이 각 부대역에서 산출되므로 각 적응 필터의 구현상 복잡성을 감소시킨다.

  • PDF

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

A Study on Fusion and Visualization using Multibeam Sonar Data with Various Spatial Data Sets for Marine GIS

  • Kong, Seong-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.407-412
    • /
    • 2010
  • According to the remarkable advances in sonar technology, positioning capabilities and computer processing power we can accurately image and explore the seafloor in hydrography. Especially, Multibeam Echo Sounder can provide nearly perfect coverage of the seafloor with high resolution. Since the mid-1990's, Multibeam Echo Sounders have been used for hydrographic surveying in Korea. In this study, new marine data set as an effective decision-making tool in various fields was proposed by visualizing and combining with Multibeam sonar data and marine spatial data sets such as satellite image and digital nautical chart. The proposed method was tested around the port of PyeongTaek-DangJin in the west coast of Korea. The Visualization and fusion methods are described with various marine data sets with processing. We demonstrated that new data set in marine GIS is useful in safe navigation and port management as an efficient decision-making tool.

Numerical modeling and simulation technique in time-domain for multibeam echo sounder

  • Jung, Donghwan;Kim, Jeasoo;Byun, Gihoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권2호
    • /
    • pp.225-234
    • /
    • 2018
  • A Multibeam Echo Sounder (MBES) is commonly used for rapid seafloor mapping. We herein present a time-domain integrated system simulation technique for MBES development. The Modeling and Simulation (M&S) modules consist of four parts: sensor array signal transmission, propagation and backscattering modeling in the ocean environment, beamforming of the received signals, and image processing. Also, the simulation employs a ray-theory-based algorithm to correct the reconstructed bathymetry, which has errors due to the refraction caused by the vertical sound velocity profile. The developed M&S technique enables design parameter verification and system parameter optimization for MBES. The framework of this technique can also be potentially used to characterize the seabed properties. Finally, typical seafloor images are presented and discussed.

슬관절 연골 연화증의 진단에서의 Dual Echo in Steady State (DESS) 영상의 유용성 : 급속 스핀에코 자기공명 영상과 비교 (Usefulness of Dual-Echo in Steady State (DESS) Image in Chondromalacia of Knee Joint: Comparison of DESS and Turbo Spin-Echo MR Images)

  • 윤삼현;하두회
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권1호
    • /
    • pp.66-72
    • /
    • 1999
  • 목적: 급속 스핀 에코 MR영상과 Dual Echo in Steady State(DESS) 영상을 비교하여 슬관절 연골 연화증의 병소 발견에 있어서 DESS 영상의 유용성을 알아 보고자 하였다. 대상 및 방법: 1997년 1월부터 1998년 7월까지 관절경 수술과 자기 공명 영상을 시해안 환자중 수술 소견에서 슬관절의 연골 연화가 있었던 26명(남:여=14:12, 평균 46.3세)을 대상으로 하였다. 1.5 T 자기 공명 장치를 사용하였고, 급속 스핀 에코 양자 밀도와 T2 강조영상의 게측 게수로써 TR/TE 3000-4200/16-96msec, FOV $140-160{\times}150-160$, matrix size $180{\times}256$, 절편 두께 4.0mm, 절편 간격은 0.5mm로 하였으며, DESS 영상의 계측계수로써 TR/TE 25.4/9.0msec, filp angle $35-35^{\circ}$, FOV $150-160{\times}150-160mm$, matrix size $192{\times}256$, 효과적 절편 두께 1.5mm로 하였으며, DESS 영상은 시상단면을, 양자 밀도 강조 영상과 T2 강조영상은 시상 단면과 관상 단면을 얻어 비교하였다. 영상의 분석은 2명의 방사선과 의사가 합의하여 후향적으로 분석하였고, 슬개-대퇴 구획, 슬관절의 내측, 외측 구획으로 나누었으며, 자기 공명 영상과 관절경 소견의 등급은 0: 정상, I: 연화 또는 수포, II: 표층 균열, III: 심층 균열, IV: 전층 균열 또는 골노출로 나누었고, 각각의 민감도, 특이도, 그리고 정확도를 구하였다. 결과: 관절경 소견상 I등급 7예, II등급 21예, III등급 6예, IV등급은 18예 였으며, 급속 스핀 에코 자기공명 영상에서의 관절경 소견과 구획과 등급이 일치했던 경우는 등급별로 0%, 14%, 0%, 61%로 나타났으며, DESS 영상에서는 각각 0%, 33%, 50%, 67% 이었다(p=0.001). 또한 각 부위에서 등급을 고려하지 않은 경우, 고식적 자기공명 영상에서의 민감도, 특이도, 그리고 정확도는 59.6%, 88.6%, 78.8% 였으며, DESS 영상에서는 73.1%, 88.4%, 82.2%로 나타났다(p=0.007). 결론: 슬관절의 연골 연화증의 진단에 있어서 DESS 영상이 급속 스핀 에코 자기공명영상보다 높은 발견율과 민감도를 보였다. 그러므로 급속 스핀 에코 MR 영상과 더불어 DESS 영상이 슬관절 연골연화즈의 진단에 보다 더 도움을 줄 것으로 생각한다.

  • PDF

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.