• 제목/요약/키워드: Earthquake Resisting Structure

검색결과 107건 처리시간 0.023초

조적채움벽이 있는 1/5 축소 3층 비연성 철근콘크리트 골조의 진동대 실험 (Shaking Table Test of a 1/5 Scale 3-Story Nonductile infilled Reinforced Concrete Frame)

  • 이한선;우성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.541-546
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA`s) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period of the model.

  • PDF

비내진 상세를 가진 3층 철근콘크리트 골조의 비탄성 거동 (Inelatic Behaviors of A 3-Story Reinforced Concrete Frame with Nonseismic Details)

  • 이한선;우성우;허윤섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.427-432
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting reinforced frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA's) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. The base shear was measured by using specially made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period and damping ratio of the model.

  • PDF

Earthquake behavior of stiffened RC frame structures with/without subsoil

  • Ozdemir, Y.I.;Ayvaz, Y.
    • Structural Engineering and Mechanics
    • /
    • 제28권5호
    • /
    • pp.571-585
    • /
    • 2008
  • The purpose of this study is to investigate the linear earthquake behavior of the frame structures including subsoil with different stiffening members and to compare the results of each frame considered. These comparisons are made separately for displacement, bending moments and axial forces for frames with different storey and bay numbers for the time history and the modal analyses. The results of both methods are also compared. The results of the frames with subsoil are also compared with the results of the frames without subsoil. It is concluded that all stiffening members considered in this study decrease the lateral displacement of the frame and the bending moment of the columns and increase the axial force in the columns and that configuration of the bracing members come out to be an important parameter in braced frames since the frames with the same type of bracing give different results depending on configuration. It is also concluded that, in general, the absolute maximum displacements of the frames modeled with subsoil are larger than those of the frames modeled without subsoil.

Identifying the hysteretic energy demand and distribution in regular steel frames

  • Akbas, Bulent;Shen, Jay;Temiz, Hakan
    • Steel and Composite Structures
    • /
    • 제6권6호
    • /
    • pp.479-491
    • /
    • 2006
  • Structures in seismic regions are designed to dissipate seismic energy input through inelastic deformations. Structural or component failure occurs when the hysteretic energy demand for a structure or component subject to an earthquake ground motion (EQGM) exceeds its hysteretic energy dissipation capacity. This paper presents a study on identifying the hysteretic energy demand and distribution throughout the height of regular steel moment resisting frames (SMRFs) subject to severe EQGMs. For this purpose, non-linear dynamic time history (NDTH) analyses were carried out on regular low-, medium-, and high-rise steel SMRFs. An ensemble of ninety EQGMs recorded on different soil types was used in the study. The results show that the hysteretic energy demand decreases from the bottom stories to the upper stories and for high-rise structures, most of the hysteretic energy is dissipated by the bottom stories. The decrease is quite significant, especially, for medium- and high-rise structures.

현행 내진설계 규준에서 요구되는 수평강도의 평가 방법 (Method of Evaluation of the Strength Required in Current Seismic Design Code)

  • 한상환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.193-200
    • /
    • 1997
  • Current seismic design code is based of the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, base shear forces required to maintain target ductility ratio were first calculated from nonlinear dynamic analysis on the single degree of freedom system. And then, base shear foeces specified in seismic design code compare with above results. If the strength(base shear) required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of static nonlinear analysis(push-over analysis).analysis).

  • PDF

지반강성을 고려한 중저층 가새모멘트저항골조의 내진 목표성능평가 (Seismic Object Performance Evaluation of Braced Steel Moment Resisting Frames with Low Rise Building under Different Site Stiffness)

  • 김수정;최병정;박호영;이진우
    • 한국지진공학회논문집
    • /
    • 제20권2호
    • /
    • pp.91-101
    • /
    • 2016
  • This study is the compared seismic performance that are difference between the performance of structures on various site classes and beam-column connection. this analysis model was designed the previous earthquake load. To compare the performance levels of the structure was subjected to nonlinear static and nonlinear dynamic analysis. Nonlinear analysis was used to The Perform 3D program. Nonlinear static analysis was compared with the performance point and Nonlinear dynamic analysis was compared the drift ratio(%). Analysis results, the soft site class of the displacement was more increase than rock site classes of the displacement. Also The smaller the displacement was increased beam-column connection stiffness.

비좌굴 가새골조의 층별 이력에너지 분포 (A Story-wise Distribution of Hysteretic Energy in Buckling-Restrained Braced Frames)

  • 최현훈;김진구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.286-293
    • /
    • 2003
  • In this study a story-wise distribution of hysteretic energy in multi-story steel moment-resisting framse (MRE), buckling restrained braced frames (BRBF-R), and hinge-connected framed structures with buckling restrained braces (BRBF-H) subjected to various earthquake ground excitations was investigated. According to analysis results the hysteretic energy in MRF and BRBF-R turned out to be the maximum at the base and monotonically diminishes with increasing height. In top stories the plastic deformation of members is almost negligible. However the story-wise distribution of hysteretic energy in BRBF-H was relatively uniform over the height of the structure. This is considered to be more desirable because damage is not concentrated in a single story.

  • PDF

A risk-based framework for design of concrete structures against earthquake

  • Hassani, Mohammadhassan;Behnam, Behrouz;Maknoon, Reza
    • Computers and Concrete
    • /
    • 제25권2호
    • /
    • pp.167-179
    • /
    • 2020
  • Optimal design of structures against earthquake loads is often limited to reduce initial construction costs, while the cost induced to structures during their useful life may be several times greater than the initial costs. Therefore, it is necessary to consider the indirect costs due to earthquakes in the design process. In this research, an integrated methodology for calculating life cycle cost (LCC) of moment-resisting concrete frames is presented. Increasing seismic safety of structures and reducing human casualties can play an important role in determining the optimal design. Costs incurred for structures are added to the costs of construction, including the costs of reconstruction, financial losses due to the time spent on reconstruction, interruption in building functionality, the value of people's life or disability, and content loss are a major part of the future costs. In this research, fifty years of useful life of structures from the beginning of the construction is considered as the life cycle. These costs should be considered as factors of calculating indirect costs of a structure. The results of this work represent the life cycle cost of a 4 story, 7 story, and 10 story moment-resisting concrete frame by details. This methodology is developed based on the economic conditions of Iran in 2016 and for the case of Tehran city.

2층 조적조의 지진하중에 의한 거동해석 및 균열평가 (Response Analysis and crack Pattern Evaluation of Two Story Masonry Structure under the seismic Load)

  • 김희철;이경훈
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.179-190
    • /
    • 1998
  • 현재 국내에는 조적조 건물에 대한 내진규준이 마련되어 있지 않다 반면 최근 들어 한반도에 발생하는 지진의 반도수는 계속증가하고 있어 조적조 건물에 대한 지진하중에 의한 평가가 이루어져야 한다. 본 연구에서는 2층 조적조 건물에 국내에서 발생 가능한 최대지진가속도인 0.12g의 지진하중을 적용한 유한요소해석법에 의한 방법으로 동적해석을 수행한 결과 2층에 비하여 1층에서 불안전한 거동이 발생하였다 특히 개구부 주위 및 테두리 보와 조적벽의 경계부분에서 허용응력을 초과하여 균열이 발생함을 알 수 있었다.

  • PDF

Comparison of seismic progressive collapse distribution in low and mid rise RC buildings due to corner and edge columns removal

  • Karimiyan, Somayyeh
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.649-665
    • /
    • 2020
  • One of the most important issues in structural systems is evaluation of the margin of safety in low and mid-rise buildings against the progressive collapse mechanism due to the earthquake loads. In this paper, modeling of collapse propagation in structural elements of RC frame buildings is evaluated by tracing down the collapse points in beam and column structural elements, one after another, under earthquake loads and the influence of column removal is investigated on how the collapse expansion in beam and column structural members. For this reason, progressive collapse phenomenon is studied in 3-story and 5-story intermediate moment resisting frame buildings due to the corner and edge column removal in presence of the earthquake loads. In this way, distribution and propagation of the collapse in progressive collapse mechanism is studied, from the first element of the structure to the collapse of a large part of the building with investigating and comparing the results of nonlinear time history analyses (NLTHA) in presence of two-component accelograms proposed by FEMA_P695. Evaluation of the results, including the statistical survey of the number and sequence of the collapsed points in process of the collapse distribution in structural system, show that the progressive collapse distribution are special and similar in low-rise and mid-rise RC buildings due to the simultaneous effects of the column removal and the earthquake loads and various patterns of the progressive collapse distribution are proposed and presented to predict the collapse propagation in structural elements of similar buildings. So, the results of collapse distribution patterns and comparing the values of collapse can be utilized to provide practical methods in codes and guidelines to enhance the structural resistance against the progressive collapse mechanism and eventually, the value of damage can be controlled and minimized in similar buildings.