• Title/Summary/Keyword: Earth resistivity

Search Result 468, Processing Time 0.021 seconds

염수침입 현상의 전기비저항 분석에 대한 지구통계기법의 응용

  • 심병완;정상용;김병우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.92-96
    • /
    • 2001
  • Although the problem of seawater intrusion at the coastal aquifer was recognized before over one hundred years at the coastal aquifer, much groundwater keep on being salinitized by several reasons such as groundwater exhaustion, coastalline change, and human activities. The horizontal and vertical electrical soundings and geostatistical methods were used to define the local characteristics of saltwater intrusion and to estimate the saltwater interface in the southeastern area of the Pusan City. The 24 points of the Schlumberger vertical electrical soundings(VES) to loom depth and the 2 lines of dipole-dipole horizontal soundings are peformed. The resistivity data have lognormal distributions. The horizontal extents of saline water intrusion were estimated from the inversion of horizontal prospecting data. Lognormal ordinary kriging is used in A-A' resistivity profiles on May and July because the data have stationary models in semivariograms. Lognormal IRF-k kriging is used for the isopleth maps using vertical resistivity data. The 10 ohm-m resistivity line on the isopleth maps of 21m, 30m, 50m, and 70m depth using resisitivity data measured in July is sifted to the east, cpomparing that of the isopleth maps measured in May. The kriged vertical and horizontal resistivity isopleth maps suggested that the geostatistical methods can be used to define the variation of earth resistivity distribution at the saltwater interface.

  • PDF

Investigation of Coring Grounding Construction by Equivalent Radius Concept (등가반경개념에 의한 코어링 접지공사의 고찰)

  • 김세호;김일환;양문길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.103-110
    • /
    • 2003
  • The grounding system is necessary to provide means to dissipate electric currents into the earth without exceeding any operating and equipment limits. The ground is composed of various soils and the resistivity of the soil depends on many parameters. It depends on the type of soil and varies with distance as well as with depth. Especially, soil resistivity of volcanic area such as Jeju is ve교 high and it is difficult to acquire necessary grounding resistivity. This paper introduces the efficient grounding construction using coring technique for proper grounding resistance in high resistivity area. Because it is difficult to measure the accurate resistivity of soils, their resistivities are estimated using measured value of ground resistance and equivalent radius method. Estimated resistivities are used for grounding resistance in scheduled construction region.

Application of 4-D resistivity imaging technique to visualize the migration of injected materials in subsurface (지하주입 물질 거동 규명을 위한 4차원 전기비저항 영상화)

  • Kim, Jung-Ho;Yi, Myeong-Jong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.12a
    • /
    • pp.31-42
    • /
    • 2007
  • Dc resistivity monitoring has been increasingly used in order to understand the changes of subsurface conditions in terms of conductivity. The commonly adopted interpretation approach which separately inverts time-lapse data may generate inversion artifacts due to measurement error. Eventually the contaminated error amplifies the artifacts when reconstructing the difference images to quantitatively estimate the change of ground condition. In order to alleviate the problems, we defined the subsurface structure as four dimensional (4-D) space-time model and developed 4-D inversion algorithm which can calculate the reasonable subsurface structure continuously changing in time even when the material properties change during data measurements. In this paper, we discussed two case histories of resistivity monitoring to study the ground condition change when the properties of the subsurface material were artificially altered by injecting conductive materials into the ground: (1) dye tracer experiment to study the applicability of electrical resistivity tomography to monitoring of water movement in soil profile and (2) the evaluation of cement grouting performed to reinforce the ground. Through these two case histories, we demonstrated that the 4-D resistivity imaging technique is very powerful to precisely delineate the change of ground condition. Particularly owing to the 4-D inversion algorithm, we were able to reconstruct the history of the change of subsurface material property.

  • PDF

Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System (접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰)

  • Lee, Bok-Hee;Kim, Ki-Bok;Lee, Seung-Hoon;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.

Behavior of Normalized Voltage Curves in the Resistivity Method (전기비저항 탐사에서 전위감쇠곡선의 거동특성)

  • Cho, In-Ky;Lee, Keun-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.364-369
    • /
    • 2010
  • Resistivity data should be edited before the inversion because resistivity data are contaminated by a lot of noise. Generally, outlier or data violating pants-leg effect in dipole-dipole array were used to be rejected in the apparent resistivity pseudo-section. For more precise data editing, normalized voltage curves are used. In this study, we analyzed the behavior of normalized voltage curves for pole-pole, pole-dipole and dipole-dipole arrays in the presence of threedimensional inhomogeneities, and finally re-examined the validity of normalized voltage curves in the editing process of resistivity data.

A Study on the Identification of Specific Earth Resistivity for Grounding Design of 500 KV Transmission Towers (500 kV 송전철탑 접지설계를 위한 대지저항률 산정에 관한 연구)

  • Choi, Jong-Kee;Lee, Sung-Doo;Lee, Dong-Il;Jung, Gil-Jo;Kim, Kyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.703-705
    • /
    • 2005
  • 접지설계에 있어서 토양의 전기적 특성은 접지극의 형상과 더불어 가장 중요한 설계요소 중 하나이며 이러한 토양의 전기적 특성은 접지극이 매설될 지역의 고유한 저항률, 즉 고유저항률(specific earth resistivity)로 대표되어 왔다. 이처럼 고유저항률에 근거한 수작업 접지설계는 복잡한 구조와 특성을 갖는 실제 토양을 균일한 매질로 등가화하는 절차를 필요로 한다. 본 논문에서는 미얀마 500 kV 송전철탑 수작업 접지설계를 위하여 수평다층토양을 균일매질로 등가화하는 절차를 제시하였다.

  • PDF

A Study on the Analysis of Lightning Damage Impact in Domestic Offshore Wind Farm (국내 해상풍력발전단지 낙뢰피해 영향 분석에 관한 연구)

  • Seo, Jin-Gyu;Kim, Kyu-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.247-252
    • /
    • 2016
  • The latest offshore wind turbines are easily exposed to lightning strikes because they are designed with longer blades and taller height to satisfy the growing capacity demands. The generation facilities and elements of the offshore wind farm are more vulnerable to lightning damage because of more severe, unpredictable weather conditions. Therefore, this paper presents the analysis of measure for lightning overvoltage mitigation in offshore wind farm planned in South Korea southwest seashore. The sensitivity analysis includes the steady state and transient state characteristics of offshore wind farm and proposes the countermeasure for mitigation of transient overvoltage by considering earth resistivity of the offshore environment.

Laboratory study on the electrical resistivity characteristics using an artificial agar specimen with clay minerals (점토광물을 함유하는 한천인공시료를 이용한 전기비저항 특성에 관한 실험적 연구)

  • Park, Mi-Kyung;Park, Sam-Gyu;Kim, Hee-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.65-70
    • /
    • 2005
  • A low resistivity zone is found in many places such as a fractured fault zone, weathered zone and aquifer. The electrical resistivity is influenced mainly by pore fluid as well as the clay mineral types and contents, Hence, it is very important to understand the relationship between the electrical resistivity and clay contents associated with the low resistivity zone for geotechnical applications such as civil engineering. This study examines the characteristics of clay mineral types and contents to electrical resistivity through sample measurements, and proposes an expression relating the resistivity and clay content. The electrical resistivity is measured for an artificial agar specimen with clay minerals instead of a natural rock. The clay minerals used are Kaolinite and Montmorillonite. Montmorillonite shows remarkably lower resistivity than Kaolinite, although its clay content is fewer than that of Kaolinite. Also, the proposed expression shows a good correlation coefficient as high as 0.89 or more in all clay minerals.

  • PDF

A Relationship between Hydraulic Conductivity and Electrical Properties of Silty Sand on the Riverside of the Nakdong River (낙동강변 실트질 모래의 수리전도도와 전기적 물성과의 관계)

  • Kim, Soo-Dong;Park, Samgyu;Hamm, Se-Yeong;Oh, Yun-Yeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.39-46
    • /
    • 2014
  • Hydraulic conductivity is an important parameter, representing permeable property of the groundwater in aquifers, in the issues of groundwater development, groundwater contamination, and groundwater flow, etc. We estimated a relationship between hydraulic conductivity and electrical properties (formation factor, chargeability, and time constant) of silty sand in the laboratory. For this study, we conducted grain size analysis, constant head permeameter test, and measured electrical resistivity and spectral induced polarization of silty sand samples collected from the riverside alluvium of the Nakdong River in Nogok-ri area, Dasan-myeon, Goryeong-gun in Gyeongbook Province, Korea. In the laboratory test, we used soil samples of approximately uniform porosity with 0.5% error range, and kept the electrical resistivity of pore water with 100 ohm-m. As a result, the relationship between effective particle size and hydraulic conductivity agrees fairly well with the existing empirical formulas. Hydraulic conductivity was correlated with formation factor, chargeability, and time constant: hydraulic conductivity increased with increasing formation factor and time constant as well as with decreasing chargeability.

Monitoring and detecting $CO_2$ injected into water-saturated sandstone with joint seismic and resistivity measurements (탄성파 및 비저항 동시측정에 의한 수포화 암석시료에 주입된 $CO_2$ 모니터링 및 탐지)

  • Kim, Jong-Wook;Matsuoka, Toshifumi;Xue, Ziqiu
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.58-68
    • /
    • 2011
  • As part of basic studies of monitoring carbon dioxide ($CO_2$) storage using electrical and seismic surveys, laboratory experiments have been conducted to measure resistivity and P-wave velocity changes due to the injection of $CO_2$ into water-saturated sandstone. The rock sample used is a cylinder of Berea sandstone. $CO_2$ was injected under supercritical conditions (10 MPa, $40^{\circ}C$). The experimental results show that resistivity increases monotonously throughout the injection period, while P-wave velocity and amplitude decrease drastically due to the supercritical $CO_2$ injection. A reconstructed P-wave velocity tomogram clearly images $CO_2$ migration in the sandstone sample. Both resistivity and seismic velocity are useful for monitoring $CO_2$ behaviour. P-wave velocity, however, is less sensitive than resistivity when the $CO_2$ saturation is greater than ~20%. The result indicates that the saturation estimation from resistivity can effectively complement the difficulty of $CO_2$ saturation estimations from seismic velocity variations. By combining resistivity and seismic velocity we were able to estimate $CO_2$ saturation distribution and the injected $CO_2$ behaviour in our sample.