• Title/Summary/Keyword: Earlier Detection

Search Result 174, Processing Time 0.028 seconds

Big Data Analysis of Software Performance Trend using SPC with Flexible Moving Window and Fuzzy Theory (가변 윈도우 기법을 적용한 통계적 공정 제어와 퍼지추론 기법을 이용한 소프트웨어 성능 변화의 빅 데이터 분석)

  • Lee, Dong-Hun;Park, Jong-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.997-1004
    • /
    • 2012
  • In enterprise software projects, performance issues have become more critical during recent decades. While developing software products, many performance tests are executed in the earlier development phase against the newly added code pieces to detect possible performance regressions. In our previous research, we introduced the framework to enable automated performance anomaly detection and reduce the analysis overhead for identifying the root causes, and showed Statistical Process Control (SPC) can be successfully applied to anomaly detection. In this paper, we explain the special performance trend in which the existing anomaly detection system can hardly detect the noticeable performance change especially when a performance regression is introduced and recovered again a while later. Within the fixed number of sampling period, the fluctuation gets aggravated and the lower and upper control limit get relaxed so that sometimes the existing system hardly detect the noticeable performance change. To resolve the issue, we apply dynamically tuned sampling window size based on the performance trend, and Fuzzy theory to find an appropriate size of the moving window.

Burned Area Detection After Wildfire Using Landsat 7 ETM+ SLC-off Images

  • Quoc, Khanh Le;Sy, Tan Nguyen;Nhat, Thanh Nguyen Thi;Thanh, Ha Le
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.2 no.3
    • /
    • pp.117-129
    • /
    • 2013
  • The increasing demand for monitoring wildfires and their impact on the land surface have prompted studies of burned area extraction and analysis. To differentiate burned and unburned area, the earlier method of the Moderate Resolution Imaging Spectro-radiometer (MODIS) Burned Area Detection Algorithm was proposed to estimate the change in land surface based on the reflectance energy. The energy, whose wavelengths are sensitive to burning, was selected to calculate the change parameter $Z_{score}$. This method was applied using the MODIS images to produce a MODIS Burned Area product. The approach was to simplify this algorithm to make it compatible with the Landsat 7 ETM+ SLC-off images. To extract the refined version of burned regions, post-processing was carried out by applying a median filter, dilation morphology algorithm, and finally a gap filling method. The experimental results showed that the detailed burned areas extracted from the proposed method exhibited more spatial details than those of the MODIS Burned products in the large U.S areas. The results also revealed the discontinuous distribution of burned regions in Vietnam forests.

  • PDF

Amperometric Detection of DNA by Electroreducation of O2 in an Enzyme-Amplified Two-Component Assay

  • Yoon Chang-Jung;Kim Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.44-48
    • /
    • 2004
  • The two-component type enzyme amplified amperometric DNA assay is described to use an ambient $O_2$ of the substrate of the DNA labeling enzyme. Although the assay detects DNA only at > 0.5M concentration, a concentration $\~10^6$ fold higher than the sandwich-type enzyme amplified amperometric DNA assay, it can be run with an always available substrate. The assay utilizes screen-printed carbon electrodes (SPEs) which were pre-coated by a co-electrodeposited film of an electron conducting redox hydrogel and a 37-base long single-stranded DNA sequence. The DNA in the electron conducting film hybridizes and captures, when present, the 37-base long detection-DNA, which is labeled with bilirubin oxidase (BOD), an enzyme catalyzing the four-electron reduction of $O_2$ to water. Because the redox hydrogel electrically connects the BOD reaction centers to the electrode, completion of the sandwich converts the film from non-electrocatalytic to electrocatalytic for the reduction of $O_2$ to water when the electrode is poised at 200 mV vs. Ag/hgCl. The advantage or the assay over the earlier reported sandwich type enzyme amplified amperometric DNA assay, in which the amplifying enzyme was horseradish peroxidase, is that it utilizes ambient $O_2$ instead of the less stable and naturally unavailable $H_2O_2$.

Pre-diagnosis Management in WSN based Portable Healthcare Monitoring System (무선센서네트워크 기반 휴대용 헬스케어 모니터링 시스템을 위한 휴대폰 자체 간이진단 관리)

  • Hii, Pei-Cheng;Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.538-541
    • /
    • 2009
  • Increasing of number of people who suffered from long term chronic diseases which required frequent daily health monitoring and body check up in conjunction with the trendy uses of mobile phones and Personal Digital Assistants (PDAs) in various ubiquitous computing had make portable healthcare system a well known application today. A mobile phone based portable healthcare monitoring system with multiple vital signals monitoring ability at real time in WSN and CDMA network is developed. This system carries out real time monitoring and local data analysis process in the mobile phone. Any detection of abnormal health condition and diagnosis at earlier stage will reduce the risk of patient's life. As an extension to the existing model, a pre-diagnosis management system (PDMS) is designed to minimize the time consuming in pre-diagnosis process in the hospital or healthcare center. An alert is sent to the web server at the healthcare center when the patient detects his health is at critical state where the immediate diagnosis is needed. Preparation of diagnosis equipments and arrangement of doctor and nurses at the hospital side can be done earlier before the arrival of patient at the hospital with the help of PDMS. An efficient pre-diagnosis management increases the chances of diseases recovery rate as well.

  • PDF

Detection of Micro-Crack Using a Nonlinear Ultrasonic Resonance Parameters (비선형 초음파공명 특성을 이용한 미세균열 탐지)

  • Cheong, Yong-Moo;Lee, Deok-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.369-375
    • /
    • 2012
  • In order to overcome the detection limit by the current nondestructive evaluation technology, a nonlinear resonant ultrasound spectroscopy(NRUS) technique was applied for detection of micro-scale cracks in a material. A down-shift of the resonance frequency and a variation of normalized amplitude of the resonance pattern were suggested as the nonlinear parameter for detection of micro-scale cracks in a materials. A natural-like crack were produced in a standard compact tension(CT) specimen by a low cycle fatigue test and the resonance patterns were acquired in each fatigue step. As the exciting voltage increases, a down-shift of resonance frequency were increases as well as the normalized amplitude decrease. This nonlinear effects were significant and even greater in the cracked specimen, but not observed in a intact specimen.

Ultrasonic guided waves-based fatigue crack detection in a steel I-beam: an experimental study

  • Jiaqi Tu;Xian Xu;Chung Bang Yun;Yuanfeng Duan
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.13-27
    • /
    • 2023
  • Fatigue crack is a fatal problem for steel structures. Early detection and maintenance can help extend the service life and prevent hazards. This paper presents the ultrasonic guided waves-based (UGWs-based) fatigue crack detection of a steel I-beam. The semi-analytical finite element model has been built to obtain the wave propagation characteristics. Damage indices in both time and frequency domains were analyzed by considering the characteristic variations of UGWs including the amplitude, phase angle, and wave packet energy. The pulse-echo and pitch-catch methods were combined in the detection scheme. Lab-scale experiments were conducted on welded steel I-beams to verify the proposed method. Results show that the damage indices based on the characteristic variations in the time domain can identify and localize the fatigue crack before it enters the rapid growth stage. The damage severity can be reasonably evaluated by analyzing the time-domain damage indices. Two nonlinear damage indices in the frequency domain give earlier warnings of the fatigue crack than the time-domain damage indices do. The identification results based on the above two nonlinear indices are found to be less consistent under various excitation frequencies. More robust nonlinear techniques needed to be searched and tested for early crack detection in steel I-beams in further study.

Detection of Traffic Light using Color after Morphological Preprocessing (형태학적 전처리 후 색상을 이용한 교통 신호의 검출)

  • Kim, Chang-dae;Choi, Seo-hyuk;Kang, Ji-hun;Ryu, Sung-pil;Kim, Dong-woo;Ahn, Jae-hyeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.367-370
    • /
    • 2015
  • This paper proposes an improve method of the detection performance of traffic lights for autonomous driving cars. Earlier detection methods used to adopt color thresholding, template matching and based learning maching methods, but its have some problems such as recognition rate decreasing, slow processing time. The proposed method uses both detection mask and morphological preprocessing. Firstly, input color images are converted to YCbCr image in order to strengthen its illumination, and horizontal edge components are extracted in the Y Channel. Secondly, the region of interest is detected according to morphological characteristics of the traffic lights. Finally, the traffic signal is detected based on color distributions. The proposed method showed that the detection rate and processing time improved rather than the conventional algorithm about some surrounding environments.

  • PDF

The Human Performance Degradation in Vigilance due to Prolonged and Monotonous Tasks (경계(警戒) 임무(任務) 담당자(擔當者)의 시간지연(時間遲延)에 따르는 인간(人間) 성능(性能)의 변화(變化)에 대(對)한 연구(硏究) 및 개선방안(改善方案))

  • Myun-Woo,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 1974
  • This study is aimed at a validation of the vigilance simulation model which was proposed earlier (2). The model estimates a perceived danger value, an alertness level and the probability of detection at a given elapsed time of vigilance. Twenty-nine male and seven female subjects were given a simple task. They were asked to detect a number(four numbers out of six digits in the telephone directory which have the probability of occurrence in the range of 0.0010-0.0018) in six different experimental conditions, for periods of two to three hours. Analysis of the experiments showed that although the mean detection rate varied slightly in two hours, the within-subject variance and the number of cyclic performance fluctuations increased significantly. A primal factor that affects the performance seems to be the frequency of target occurrence. By curve fitting, the relation between the probability of detection and the percentages of danger event occurrence was derived; $y=0.50(1-{\varepsilon}^{-50x^2})+0.39$. Assuming the equation represents the normal detection rate(100% performance), the Relative Vigilance Performance Rating was calculated. This rating method could be a useful criterion in selecting and training of the vigilance personnel. The results show that the simulation model is a good estimator of human a performance when the probability of danger occurrence is greater than 0.0015; it gives a good reference for improving the vigilance system. Suggestions are made that (1) the validity of proposed functional equations over the extended range of danger probability be studied, (2) an analysis of the cyclic fluctuations of the alertness level be accomplished, and (3) the cost functions of detection reliability be included in any future model.

  • PDF

Maternal and Child Factors Associated with Early Detection of Cerebral Palsy (뇌성마비아 조기발견과 관련된 모자인자)

  • Bae, Sung-Soo;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.312-321
    • /
    • 1987
  • To investigate the maternal and child factors associated with early detection of cerebral palsy, 74 mothers of cerebral palsy children who were born since January 1, 1980 and being treated at Taegu Rehabilitation Center for the Handicapped, Rehabilitiation Center of Taegu University, St. Paul Children's House and Pusan Welfare Association of Cerebral Palsy Children were interviewed from February to April 1987. There is no association between age of child when parents noticed the child's abnormality and educational level of father but it tend to be detected earlier when education level of mother is college or above compared with high school or under. There is a trend of earlier detection of child's abnormality although statistically not significant in case father is professional or managerial worker, monthly income of father is over \610,000, child is first-born, age of the parents is 34 years or under, child is a boy, and child has periodic well-baby check-up. The child's abnormality is detected earlier when mothers had 7 prenatal visits or more compared with those who had 6 visits or less (p<0.05). Parents noticed the child's abnormality first in 85.1% of the cases whereas doctors detected it first in 2.7% and this percentage was not different whether the child had periodic well-baby check-up or not. The first physician's diagnosis of the children was cerebral palsy in 36.5% and the rest was normal, need for observation, uncertain, etc. Parents took the child to doctor for diagnosis 2-3 months after they noticed the child's abnormality and after the child was diagnosed as cerebral palsy parents either took no therapeutic measure or brought the child to physiotherapy or acupuncture or gave herb medicine before they started specific rehabilitative therapy. For early detection of the cerebral palsy children, teaching of evaluation method for child development should be reinforced both in medical school and clinical training course and should train the specialist for diagnosis and treatment of crippling conditions. Also, public education is needed for the importance of early detection of crippling conditions and currently available methods for diagnosis and treatment.

  • PDF

Performance Estimation of an Implantable Epileptic Seizure Detector with a Low-power On-chip Oscillator

  • Kim, Sunhee;Choi, Yun Seo;Choi, Kanghyun;Lee, Jiseon;Lee, Byung-Uk;Lee, Hyang Woon;Lee, Seungjun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.169-176
    • /
    • 2015
  • Implantable closed-loop epilepsy controllers require ideally both accurate epileptic seizure detection and low power consumption. On-chip oscillators can be used in implantable devices because they consume less power than other oscillators such as crystal oscillators. In this study, we investigated the tolerable error range of a lower power on-chip oscillator without losing the accuracy of seizure detection. We used 24 ictal and 14 interictal intracranial electroencephalographic segments recorded from epilepsy surgery patients. The performance variations with respect to oscillator frequency errors were estimated in terms of specificity, modified sensitivity, and detection timing difference of seizure onset using Generic Osorio Frei Algorithm. The frequency errors of on-chip oscillators were set at ${\pm}10%$ as the worst case. Our results showed that an oscillator error of ${\pm}10%$ affected both specificity and modified sensitivity by less than 3%. In addition, seizure onsets were detected with errors earlier or later than without errors and the average detection timing difference varied within less than 0.5 s range. The results suggest that on-chip oscillators could be useful for low-power implantable devices without error compensation circuitry requiring significant additional power. These findings could help the design of closed-loop systems with a seizure detector and automated stimulators for intractable epilepsy patients.