• Title/Summary/Keyword: Ear-based

Search Result 333, Processing Time 0.027 seconds

Morphological Classification of the Korean Local Corn Lines (재래종(在來種) 옥수수의 형태적(形態的) 특성(特性)에 의(依)한 분류(分類))

  • Kwon, Kyeong Hak;Choe, Bong Ho
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.1
    • /
    • pp.1-16
    • /
    • 1986
  • This experiment was carried out to obtain genetic information for future corn breeding. The materials used for the study were obtained from the nationwide collection of Korean local corn lines. A total of 262 lines were used for the study of morphological characters and for the classification of lines. Results obtained are summarized as follows; 1. The days to flowering of lines ranged from 57 days to 87 days. Most lines had an average of 67 days of flowering days. 2. The number of tillers of lines showed a lot of variation among lines with 49.2% of coefficient of variation. 3. The coefficients of variation computed based on the phenotypic observation or measurement of each line were 36.1%, 27.2%, 20.0%, 16.4% and 16.3% for kernel weight per ear, 100 kernel weight, ear height, plant height and ear length, respectively. 4. Ear height, ear length, ear diameter, tiller number and days to flowering were highly and positively correlation with the plant height. Kernel size, ear size, and plant height were highly correlated with 100 kernel weight and kernel weight per ear. 5. The 262 corn lines were possibly classified into four major groups by the Euclidean distance. Group I comprised 110 lines, group II 74 lines, group III 66 lines and group IV 12 lines, respectively. Group I was characterized as having early maturity, medium plant height large kernel size and large ear size. Group II had medium maturity, short plant height, medium kernel size and small ear size. Group III had medium maturity, medium plant height, large kernel size and medium ear size. Group IV had late maturity, long plant height, small kernel size, small ear size and many tillering. 6. The plant height showed significant difference between group I and II, II and III, and II and IV group. No statistical differences were observed between group III and IV. The ear size of group I was significantly different from those of group II, III and IV. Also difference of ear size between group II and III was significant. The kernel size, 100 kernel weight and kernel weight per ear were all significantly different among all groups classified. The row number was different between group I and II. The row number of lines in group IV was significantly different with group I, II, III respectively. The number of tillers and flowering days of lines in group IV were greatly different from those of group I, II and III. 7. The corn lines collected from northwest plain regions and middle hilly regions in Korea had medium maturity, medium plant height, large ear and large kernels. The corn lines from middle eastern hilly regions had medium size of ear kernels. The corn lines from middle southern hilly regions had late maturity, small kernel size and many tillers. The corn lines from southwest plain areas had late maturity, long plant height and many tillers.

  • PDF

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.

Comparison between Subjective Scoring and Computer-Based Asymmetry Assessment in Facial Nerve Palsy

  • Lee, Doh Young;Kim, Hyun Seok;Kim, So Young;Park, Kwang Suk;Kim, Young Ho
    • Journal of Audiology & Otology
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Background and Objectives: The aim of the present study was to assess the feasibility of a PC-based facial asymmetry assessment program (PC-FAAP) and to compare the results of PC-FAAP with subjective regional scoring by raters in acute unilateral peripheral facial nerve paralysis (FNP). Subjects and Methods: Participants were divided into 3 groups with 8 participants per group: group I, normal; group II, mild to moderate FNP; and group III, severe FNP. Using the PC-FAAP, the mouth asymmetry ratio (MAR), eyebrow asymmetry ratio (EAR), and complete eye closure asymmetry ratio (CAR) were calculated by comparing the movement of tracking points on both sides. The FNP grading scale (FGS) integrated each score, and the scores were weighted with a ratio of 5:3:2 (MAR:CAR:EAR). Subjective regional scoring was measured on a 0-100 scale score by three otologists. PC-FAAP and subjective scoring were compared in each group regarding the consistency of the results. Results: The mean scores of the MAR, EAR, CAR, and FGS of each group were significantly different. PC-FAAP showed significant differences between the three groups in terms of MAR, EAC, CAR, and FGS. PC-FAAP showed more consistent results than subjective assessment (p<0.001). The PC-FAAP was significantly more consistent in group I and group III (p<0.001 and p=0.002, respectively). FGS in group III was the only parameter that showed a more consistent result in PC-FAAP than the subjective scoring (p=0.008). Conclusions: An FNP grading system using a PC-based program may provide more consistent results, especially for severe forms.

Comparison between Subjective Scoring and Computer-Based Asymmetry Assessment in Facial Nerve Palsy

  • Lee, Doh Young;Kim, Hyun Seok;Kim, So Young;Park, Kwang Suk;Kim, Young Ho
    • Korean Journal of Audiology
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Background and Objectives: The aim of the present study was to assess the feasibility of a PC-based facial asymmetry assessment program (PC-FAAP) and to compare the results of PC-FAAP with subjective regional scoring by raters in acute unilateral peripheral facial nerve paralysis (FNP). Subjects and Methods: Participants were divided into 3 groups with 8 participants per group: group I, normal; group II, mild to moderate FNP; and group III, severe FNP. Using the PC-FAAP, the mouth asymmetry ratio (MAR), eyebrow asymmetry ratio (EAR), and complete eye closure asymmetry ratio (CAR) were calculated by comparing the movement of tracking points on both sides. The FNP grading scale (FGS) integrated each score, and the scores were weighted with a ratio of 5:3:2 (MAR:CAR:EAR). Subjective regional scoring was measured on a 0-100 scale score by three otologists. PC-FAAP and subjective scoring were compared in each group regarding the consistency of the results. Results: The mean scores of the MAR, EAR, CAR, and FGS of each group were significantly different. PC-FAAP showed significant differences between the three groups in terms of MAR, EAC, CAR, and FGS. PC-FAAP showed more consistent results than subjective assessment (p<0.001). The PC-FAAP was significantly more consistent in group I and group III (p<0.001 and p=0.002, respectively). FGS in group III was the only parameter that showed a more consistent result in PC-FAAP than the subjective scoring (p=0.008). Conclusions: An FNP grading system using a PC-based program may provide more consistent results, especially for severe forms.

Eosinophilic granulomas in two dogs

  • Kim, Jae-Hoon;Jung, Ji-Youl;Kang, Sang-Chul;Lee, Young-Rak;Lee, Jin-Yong;Hwang, Eui-Kyung;Woo, Gye-Hyeong;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.1
    • /
    • pp.69-72
    • /
    • 2011
  • Eosinophilic granuloma is a common hypersensitive inflammatory skin disease in cats, and rare in dogs and horses. The skin biopsies of 5 years old female Cocker spaniel and 2 years old female mixed dog had the clinical signs of skin nodules with alopecia were submitted for diagnosis. Solitary skin nodules and papillary nodules were presented on the left external ear and back of Cocker spaniel and on the external ear of mixed dog, respectively. Histopathologically, epidermis of skin showed mild to severe hyperplasia with multifocal ulceration. Small to large irregular, brightly eosinophilic foci with degenerating eosinophils and homogeneous degenerated collagens were existed in the dermis of both ear and back skin. Typical 'flame figures', a mixture of degenerated collagen and degranulated eosinophils, were observed in both cases. Based on the histopathologic findings and special staining characters, 2 cases were diagnosed as canine eosinophilic granuloma. This is the first report for the eosinophilic granuloma of dogs in Korea.

Multidirectional Vector Excision Leads to Better Outcomes than Traditional Elliptical Excision of Facial Congenital Melanocytic Nevus

  • Oh, Seung Il;Lee, Yoon Ho
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.570-574
    • /
    • 2013
  • Background The elliptical excision is the standard method of removing benign skin lesions, such as congenital melanocytic nevi. This technique allows for primary closure, with little to no dog-ear deformity, but may sacrifice normal tissue adjacent to the lesion, resulting in scars which are unnecessarily long. This study was designed to compare the predicted results of elliptical excision with those resulting from our excision technique. Methods Eighty-two patients with congenital melanocytic nevus on the face were prospectively studied. Each lesion was examined and an optimal ellipse was designed and marked on the skin. After an incision on one side of the nevus margin, subcutaneous undermining was performed in the appropriate direction. The skin flap was pulled up and approximated along several vectors to minimize the occurrence of dog-ear deformity. Results Overall, the final wound length was 21.1% shorter than that achieved by elliptical excision. Only 8.5% of the patients required dog-ear repair. There was no significant distortion of critical facial structures. All of the scars were deemed aesthetically acceptable based on their Patient and Observer Scar Assessment Scale scores. Conclusions When compared to elliptical excision, our technique appears to minimize dogear deformity and decrease the final wound length. This technique should be considered an alternative method for excision of facial nevi.

A Study of Nutritional Intakes, Food Preference and Blood Composition in Female College Students with Premenstrual Syndrome (월경전증후군 여대생의 영양소 섭취량 및 식품선호도와 혈액성상 조사)

  • Kim, Ju-Youn;Ahn, Hong-Seok
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.4
    • /
    • pp.565-572
    • /
    • 2008
  • This study was performed to investigate nutritional intakes and preference food and blood composition of female college students of premenstrual syndrome. Based on physical measurement test results, both groups showed no noticeable difference and both groups were within the normal range according to body composition analysis. In terms of nutrients consumption, results showed nutritional intakes more than EAR(estimated average requirements) included phosphorus>vitamin $B_6$>vitamin $B_1$, while nutritional intakes less than EAR were vitamin A>vitamin $B_6$>calcium>folic acid. A significant difference was observed for vitamin C intake(p<0.05). The overall mean values of basic blood(WBC, RBC, Hct, and Hb), sex hormone(Estrogen, Progesterone), aldosterone, cortisol, Cu, Zn, and Ca, Mg indices in female college students were within the normal range and there was no significant difference between the PMS group and the Normal group. In conclusion, vitamin C intake of the PMS group showed a level of 84.8% EAR. Therefore vitamin C supplement can be beneficial to relieve the PMS Syndrome.

Development of SD-OCT for Imaging the in vivo Human Tympanic Membrane

  • Cho, Nam-Hyun;Jung, Un-Sang;Kwon, Hyeong-Il;Jeong, Hyo-Sang;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.74-77
    • /
    • 2011
  • We report a novel extension of 840 nm wavelength- based spectral domain optical tomography to in vivo/real-time human middle ear diagnosis. The system was designed to access the middle ear region with a specifically dedicated handheld probe. The real-time displaying feature was mandatory for in vivo imaging human subject with the handheld probe, and the system could provide about 20 frames per second for 2048 pixels by 1000 A-scans without using any graphics process units under the Labview platform. The inner ear structure of a healthy male volunteer was imaged with the developed system with the axial and lateral resolutions of $15\;{\mu}m$ and $30\;{\mu}m$, respectively. The application of the OCT technology to early diagnose otitis media(OM) is very promising and could be another extensive branch in the OCT field because it provides the depth resolved image including tympanic membrane (TM) and structures below TM whereas the conventional otoscope technique only gives asurface image of the TM.

Identification of SNPs Related to 19 Phenotypic Traits Using Genome-wide Association Study (GWAS) Approach in Korean Wheat Mini-core Collection

  • Yuna Kang;Yeonjun Sung;Seonghyeon Kim;Changsoo Kim
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2020.06a
    • /
    • pp.120-120
    • /
    • 2020
  • Based on the simple sequence repeat (SSR) marker, a Korean wheat core collection were established with 616 wheat accessions. Among them, the SNP genotyping for the entire genome was performed using DNA chip array to clarify the whole genome SNP profiles. Consequently, a total of 35,143 SNPs were found and we re-established a mini-core collection with 247 accessions. Population diversity and phylogenetic analysis revealed genetic diversity and relationships from the mini core set. In addition, genome-wide association study (GWAS) was performed on 19 phenotypic traits; ear type, awn length, culm length, ear length, awn color, seed coat color, culm color, ear color, loading, leaf length, leaf width, seeding stand, cold damage, weight, auricle, plant type, heading stage, maturation period, upright habit, and degree of flag leaf. The GWAS was performed using the fixed and random model circulating probability unification (FarmCPU), which identified 14 to 258 SNP loci related to 19 phenotypic traits. Our study indicates that this Korean wheat mini-core collection is a set of germplasm useful for basic and applied research with the aim of understanding and exploiting the genetic diversity of Korean wheat varieties.

  • PDF