• 제목/요약/키워드: Ear-band

검색결과 34건 처리시간 0.027초

이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰 (Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid)

  • 정의성;성기웅;임형규;이장우;김동욱;이정현;김명남;조진호
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

다이코틱 조건에서의 라우드니스 모델에 관한 연구 (A Study on the Loudness Model in Dichotic Conditions)

  • 차정호;이정권;신성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.617-621
    • /
    • 2003
  • Existing loudness models are specified only to diotic sounds in spite of the fact that normal human beings hear dichotic sounds. Approximately, the arithmetic mean of loudness values of both ear signals has been suggested for the resultant perceived loudness. In this study, the dependence of overall loudness perception on the interaural level differences was investigated by the subjective tests. It was found that the larger the interaural level difference, the louder the perception than the mean of calculated loudness values at both ears and the lower the critical band rate or the reference level, the louder the perception than the mean value. A modified loudness model was proposed to he applicable to dichotic sounds by using the equivalent diotic levels.

  • PDF

고주파 충격에 의한 전자부품 고장 방지 설계 (Designing Electronics for High Frequency Shock)

  • 이종학;강동석;최지호;강영식;이창민
    • 한국소음진동공학회논문집
    • /
    • 제25권10호
    • /
    • pp.700-706
    • /
    • 2015
  • In this study, stability designing electronics mounted on launch vehicle for shock load(low/high frequency band) could be derived. For the low-frequency shock loads, CCA(circuit card assembly) has secured the structural integrity over the best natural frequency techniques. For the high-frequency shock load, the structural integrity could be ensured with applying device such as the insulation pad. When the EAR is applied, insulation effect of part application is good more than whole application.

5.1 채널 스피커 시스템 음향재생을 위한 크로스토크 제거방법 (A method of the cross-talk cancellation for an sound reproduction of 5.1 channel speaker system)

  • 이수정;최갑근;김순협
    • 대한전자공학회논문지SP
    • /
    • 제42권4호
    • /
    • pp.159-166
    • /
    • 2005
  • 스피커를 이용한 5.1채널 재생시 필연적으로 나타나는 현상인 크로스토크를 제거하여 청취자에게 보다 입체적인 음을 재현하는 방법에 관한 것이다 정면 또는 후면에 위치한 스피커로부터 좌우측 귀로 입사되는 교차경로의 음을 제거하여 청취자에게 정확한 음을 제시하는 방법에 대해 기술하였다. 그리고 이것을 2채널 및 5.1 채널에 적용하여 재생하는 방법에 대해 기술하였다. 크로스토크를 제거하기 위한 방법으로는 자유음장 모델을 이용하였다. 이 모델은 음질의 왜곡을 최소화하는 장점을 가지며 근래에 들어 많은 학자들에 의해 연구되고 있다. 구체적으로 크로스토크를 제거 하는 방법으로는 정면 스피커 재생음에 대해서 가청주파수 영역에서 심리음향에 기초한 바크 스케일(bark scale)을 사용한 음질 보상방법을 사용하였으며 서라운드 채널에 관해서는 재생되는 주파수 제한대역에 근거하여 밴드패스 필터를 추가하여 크로스토크 제거를 실시하였다.

소비자 요구 분석 기반의 미세먼지 차단 마스크 디자인 개발 -어린이 및 청년층을 중심으로- (Development of Design Prototypes and Needs Analysis of Consumers of Fine Dust Mask -Focused on Children and Young Adults-)

  • 이정순;고애란;류림정;황예린;이지현
    • 한국의류학회지
    • /
    • 제43권4호
    • /
    • pp.579-591
    • /
    • 2019
  • This research investigated the needs analysis on consumers of fine dust masks to effectively develop a design prototype. Data were collected through focus group interviews on 32 individuals who have used fine dust masks. As a result, there is a new demand by consumers for technology based design changes that better fit the nose and face. Consumers preferred the smell and feel of traditional Korean paper. Young adults expressed the importance of masks that can be used for protection as well as fashion. The prototype improved the drawbacks of existing models using an origami-inspired design in a variety of colors, patterns and in sizes that are customized to fit the wearer. The proposed prototype is made of Dak felt fibers and jersey materials. It is characterized by downward-facing ear bands made of polyurethane to improve the fit around the ears and chin to more effectively block incoming air. The mask is foldable and has a crease that goes along the chin to increase the amount of enclosed space against the face making it easier to breathe compared to existing mask designs.

Comparison of the Static Balance Ability according to the Subjective Visual Vertical in Healthy Adults

  • Kwon, Jung Won;Yeo, Sang Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제32권3호
    • /
    • pp.152-156
    • /
    • 2020
  • Purpose: The subjective visual vertical (SVV) test is used to evaluate the otolith function in the inner ear. This study compared the different balance ability according to the results of the SVV in healthy adults. Methods: This study recruited 30 normal healthy subjects who did not have neurological and musculoskeletal disorders. The subjects were divided into experimental and control groups based on the results of SVV: experimental group, >2°; control group, <2°. The static balance ability was evaluated using the Fourier Index, which could evaluate the balance capacity objectively and quantitatively. Results: The mean angle of the SVV in the experimental and control groups was 4.44° and 0.59°, respectively. In the result of the Fourier series, the F1 frequency band in the experimental group showed a significantly higher value under one condition compared to the control group (p<0.05). In the F2-4 and F5-6 frequency bands, the experimental group showed a significant increase in the Fourier series value under the four conditions compared to the control group (p<0.05). In the F7-8 frequency band, significantly higher values of the Fourier series were observed in the experimental group under the three different conditions (p<0.05). Conclusion: These results showed increased trunk sway while maintaining static balance in the experimental group who showed a larger SVV angle compared to the control group. The SVV can be applied to evaluate the vestibular system and balance ability in normal adults.

청각 주파수 응답에 기반한 자동 모음 개시 지점 탐지 (Automatic Vowel Onset Point Detection Based on Auditory Frequency Response)

  • 장한;김학태;정길도
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.333-342
    • /
    • 2012
  • 이 논문에서는 인간 청각 시스템에 기반한 모음 개시 지점 (VOP) 탐지 방법을 제시하였다. 이 방법을 통해 '지각의' 주파수 범위, 즉 선형 음향 주파수에서의 Mel Scale을 보여준 후 일련의 삼각 Mel-weighted Filter Bank를 만들어 인간의 청각 시스템에서 대역 필터링 기능을 시뮬레이션하였다. 이러한 비선형 임계 대역 Filter Bank는 데이터 차원수를 크게 감소시키고 비선형적으로 간격을 둔 Mel 스펙트럼에서 더욱 효과적으로 포먼트를 생성하기 위해 조파들의 영향을 제거해준다. Mel 스펙트럼의 첨두 에너지 합은 각 프레임의 특징으로 추출하고 에너지 진폭이 급격히 상승하기 시작할 때의 특성은 Gabor 윈도우를 사용하여 VOP로 탐지한다. 실험 결과를 통해서 다른 종류의 자음들과 연결된 12개의 모음들을 포함하는 한 단어 데이터베이스에 대한 제안된 방법의 평균 정확도는 단시간 에너지와 zero-crossing 비율에 기반을 둔 다른 모음 탐지 방법들보다 높은 72.73% 이상임을 확인하였다.

The Distribution Condition and Clothing Construction Factors of the Working Clothes - Reference to the Changwon National Industrial Complex -

  • Park, Gin-Ah;Park, Hye-Won
    • 패션비즈니스
    • /
    • 제12권3호
    • /
    • pp.116-135
    • /
    • 2008
  • To investigate the actual distribution condition and clothing construction factors of the working clothes supplied to the Changwon national industrial complex, 5 major companies in machinery, automotive, industrial engineering, shipbuilding and rolling stock in the industrial complex located in Gyeongsangnam-Do were selected. The questionnaire designed for the research consisted of working clothes distribution policies in manufacturing industry and the actual conditions of the design facts, repair and maintenance of the working clothes, etc. The analysis of the clothing construction factors of the working clothes provided by 5 respondent companies were conducted in parallel. The results derived from the study were as follows: The basic types of working clothes were the blouson jacket and straight pants; safety equipments for manufacture were safety helmets, gloves, snickers, goggles, masks, ear caps, wristlets, leggings, apron, etc. The size-charts adopted by the participant companies were the small-medium-large and cm/inch measurement size systems. To solve wearer's dissatisfaction with the garment fit, certain clothing construction factors were used, e.g. strap bands and the elastic band on a waist band. The types of fabrics used for the working clothes were mainly polyester/cotton and polyester/rayon blended ones. Moreover, to provide with more air permeability to wearers, the warp knit material was used to construct the lining and the armpit or back bodice slits. Lock, two-thread chain, safety, overedge stitches were applied with flat, lap felled, French, superimposed, lapped, bound and edge finishing seams to construct the working clothes selected.

Can Narrow Band Chirp Stimulus Shake the Throne of 500 Hz Tone Burst Stimulus for Cervical Vestibular Myogenic Potentials?

  • Ocal, F Ceyda Akin;Karacayli, Ceren;Coban, Volkan Kenan;Satar, Bulent
    • Journal of Audiology & Otology
    • /
    • 제25권2호
    • /
    • pp.98-103
    • /
    • 2021
  • Background and Objectives: The aim of the study was to compare effects of tone-burst (TB) and narrow-band (NB) Claus Elberling (CE)-chirp stimuli on amplitude, latency and interaural asymmetry ratio (IAR) of cervical vestibular evoked myogenic potentials (cVEMP) in healthy individuals. Subjects and Methods: The study included 50 healthy volunteers. cVEMP procedure was carried out using 500 Hz TB and NB-CE-chirp stimulus (360-720 Hz, up-chirp) in random order. cVEMP were recorded at 100 dB nHL. For each ear and each stimulus, P1 latency, N1 latency and P1N1 amplitude were measured. IAR was also calculated. Results: Mean age was 26.66±9.48 years. cVEMP's in response to both TB and NB CE-chirp stimuli were obtained in all subjects. No statistically significant difference in P1 latency, N1 latency, and P1N1 amplitude was found between the right and left ears for both TB and NB CE-chirp stimuli (p>0.05). In both sides, P1 and N1 latencies were significantly shorter in NB CE-chirp stimulation compared to TB stimulation (p=0.000). In both sides, no statistically significant difference was found in P1N1 amplitude between two types of stimuli (p>0.05). Conclusions: The chirp stimulus produces robust but earlier cVEMP than TB does. This largest series study on NB chirp cVEMP shows that NB chirp is a good and new reliable alternative.

Can Narrow Band Chirp Stimulus Shake the Throne of 500 Hz Tone Burst Stimulus for Cervical Vestibular Myogenic Potentials?

  • Ocal, F Ceyda Akin;Karacayli, Ceren;Coban, Volkan Kenan;Satar, Bulent
    • 대한청각학회지
    • /
    • 제25권2호
    • /
    • pp.98-103
    • /
    • 2021
  • Background and Objectives: The aim of the study was to compare effects of tone-burst (TB) and narrow-band (NB) Claus Elberling (CE)-chirp stimuli on amplitude, latency and interaural asymmetry ratio (IAR) of cervical vestibular evoked myogenic potentials (cVEMP) in healthy individuals. Subjects and Methods: The study included 50 healthy volunteers. cVEMP procedure was carried out using 500 Hz TB and NB-CE-chirp stimulus (360-720 Hz, up-chirp) in random order. cVEMP were recorded at 100 dB nHL. For each ear and each stimulus, P1 latency, N1 latency and P1N1 amplitude were measured. IAR was also calculated. Results: Mean age was 26.66±9.48 years. cVEMP's in response to both TB and NB CE-chirp stimuli were obtained in all subjects. No statistically significant difference in P1 latency, N1 latency, and P1N1 amplitude was found between the right and left ears for both TB and NB CE-chirp stimuli (p>0.05). In both sides, P1 and N1 latencies were significantly shorter in NB CE-chirp stimulation compared to TB stimulation (p=0.000). In both sides, no statistically significant difference was found in P1N1 amplitude between two types of stimuli (p>0.05). Conclusions: The chirp stimulus produces robust but earlier cVEMP than TB does. This largest series study on NB chirp cVEMP shows that NB chirp is a good and new reliable alternative.