• Title/Summary/Keyword: EUS

Search Result 99, Processing Time 0.024 seconds

Accuracy of Endoscopic Ultrasonography for Determination of Tumor Invasion Depth in Gastric Cancer

  • Razavi, Seyed Mohsen;Khodadost, Mahmoud;Sohrabi, Masoudreza;Keshavarzi, Azam;Zamani, Farhad;Rakhshani, Naser;Ameli, Mitra;Sadeghi, Reza;Hatami, Khadijeh;Ajdarkosh, Hossein;Golmahi, Zeynab;Ranjbaran, Mehdi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3141-3145
    • /
    • 2015
  • Background: Gastric cancer (GC) is one the common lethal cancers in Iran. Detection of GC in the early stages would assesses to improve the survival of patients. In this study, we attempt to evaluate the accuracy of EUS in detection depth of invasion of GC among Iranian Patients. Materials and Methods: This study is a retrospective study of patients with pathologically confirmed GC. They underwent EUS before initiating the treatment. The accuracy of EUS and agreement between the two methods was evaluated by comparing pre treatment EUS finding with post operative histopathological results. Results: The overall accuracy of EUS for T and N staging was 67.9% and 75.47, respectively. Underestimation and overestimation was seen in 22 (14.2%) and 40 (25.6%) respectively. The EUS was more accurate in large tumors and the tumors located in the middle and lower parts of the stomach. The EUS was more sensitive in T3 staging. The values of weighted Kappa from the T and N staging were 0.53 and 0.66, respectively. Conclusions: EUS is a useful modality for evaluating the depth of invasion of GC. The accuracy of EUS was higher if the tumor was located in the lower parts of the stomach and the size of the tumor was more than 3 cm. Therefore, judgments made upon other criteria evaluated in this study need to be reconsidered.

Mucosal incision-assisted biopsy versus endoscopic ultrasound-assisted tissue acquisition for subepithelial lesions: a systematic review and meta-analysis

  • Suprabhat Giri;Shivaraj Afzalpurkar;Sumaswi Angadi;Sridhar Sundaram
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.615-625
    • /
    • 2022
  • Background/Aims: Mucosal incision-assisted biopsy (MIAB) for tissue acquisition (TA) from subepithelial lesions (SELs) is emerging as an alternative to endoscopic ultrasound (EUS)-guided TA. Only a limited number of studies compared the diagnostic utility of MIAB and EUS for upper gastrointestinal (GI) SELs; therefore, we conducted this systematic review and meta-analysis. Methods: A comprehensive literature search from January 2020 to January 2022 was performed to compare the diagnostic accuracy and safety of MIAB and EUS-guided TA for upper GI SELs. Results: Seven studies were included in this meta-analysis. The pooled technical success rate (risk ratio [RR], 0.96; 95% confidence interval [CI], 0.89-1.04) and procedural time (mean difference=-4.53 seconds; 95% CI, -22.38 to 13.31] were comparable between both the groups. The overall chance of obtaining a positive diagnostic yield was lower with EUS than with MIAB for all lesions (RR, 0.83; 95% CI, 0.71-0.98) but comparable when using a fine-needle biopsy needle (RR, 0.93; 95% CI, 0.83-1.04). The positive diagnostic yield of MIAB was higher for lesions <20 mm (RR, 0.75; 95% CI, 0.63-0.89). Six studies reported no adverse events. Conclusions: MIAB can be considered an effective alternative to EUS-guided TA for upper GI SELs without an increased risk of adverse events.

Updates in endoscopic ultrasonography (초음파 내시경의 최신 지견)

  • Kim, Sang-Gyun
    • Korean Journal of Bronchoesophagology
    • /
    • v.14 no.2
    • /
    • pp.17-21
    • /
    • 2008
  • Endoscopic ultrasonography (EUS) has been developed for the diagnosis of various gastrointestinal diseases or extra-gastrointestinal diseases, and extended to interventional approach. In fields of mediastinal diseases, EUS is an effective diagnostic method for the staging of esophageal cancer, lung cancer and other mediastinal diseases. Recently, EUS guided fine needle aspiration or biopsy makes the histologic diagnosis possible in various mediastinal diseases, and would reserve many avoidable surgical cases.

  • PDF

The roles of endoscopic ultrasound in the diagnosis of pancreatobiliary cancer (췌·담도암 진단에 있어서 내시경초음파의 역할)

  • Kim, Kook Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.77-84
    • /
    • 2016
  • Pancreatic cancer, the 4th leading cause of cancer-related death in the United States, has a very poor prognosis. Cholangiocarcinoma originates from either intrahepatic or extrahepatic bile duct, and its incidence is gradually increasing worldwide. Endoscopic retrograde cholangiopancreatography with brush cytology has a high false-negative rate for the diagnosis of biliary malignancy. Recently, endoscopic ultrasonography (EUS) has emerged as the potential modality to detect pancreatic cancer. EUS-guided fine needle aspiration for cytologic analysis made it possible to overcome the obstacle in differentiating between benign and malignant lesions in the pancreatobiliary lesion, and it has been well established as a safe and effective procedure. Herein, the clinical application of EUS in the diagnosis of pancreatobiliary cancer was reviewed.

Preoperative Diagnosis of Congenital Esophageal Stenosis Caused by Tracheobronchial Remnants Using Miniprobe Endoscopic Ultrasonography in a Child

  • Lee, Kun-Song
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.15 no.1
    • /
    • pp.52-56
    • /
    • 2012
  • Congenital esophageal stenosis (CES) can be classified into three types based on the etiology of stenosis: tracheobronchial remnants (TBRs), fibromuscular hypertrophy (FMH), and membranous diaphragm (MD). It is important to make a differential diagnosis because the therapeutic plan for CES is determined by its etiology. Most cases of FMH and MD can be managed with balloon dilatation, whereas cases of TBRs require resection and anastomosis. Thus, the preoperative distinction of TBRs is critical. Recently miniprobe endoscopic ultrasonography (EUS) with a maximum diameter of 2.5 mm has been useful for distinguishing TBRs from FMH in pediatric patients with CES. EUS shows hyperechoic lesions indicating TBR cartilage. Miniprobe EUS is recommended for choosing the correct therapeutic method for CES. We report a case of CES due to TBRs in which a preoperative diagnosis was made in a child using miniprobe EUS without any difficulties.

Quality indicators of endoscopic ultrasound in the pancreatobiliary system: a brief review of current guidelines

  • Sung Yong Han;Hyung Ku Chon;Seong-Hun Kim;Sang Hyub Lee
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.158-163
    • /
    • 2024
  • Since its development, the use of endoscopic ultrasonography (EUS) in the pancreas and the biliary tract has become increasingly important. The accuracy of EUS varies depending on the experience of the endoscopist. Hence, quality control measures using appropriate indicators are required to reduce these variations. American Society for Gastrointestinal Endoscopy and European Society of Gastrointestinal Endoscopy have announced the EUS quality indicators. Here, we reviewed the quality indicators of the EUS procedure in the current published guidelines.

Initial Experience with Epicardial Ultrasound Scanning in Coronary Artery Bypass Grafting

  • Kim, Dae Hyeon;Sohn, Suk Ho;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.263-269
    • /
    • 2020
  • Background: The benefits of epicardial ultrasound scanning (EUS) in coronary artery bypass grafting (CABG) have not yet been established. The aim of this study was to evaluate the usefulness of EUS in CABG, including in the assessment of the quality of distal anastomoses, the identification of epicardial target vessels, and the evaluation of any graft issues other than the distal anastomoses. Methods: Fifty-three patients undergoing CABG were enrolled between March 2018 and February 2019. Intraoperative EUS was performed along with transit-time flow measurement (TTFM). Graft evaluations were performed early (shortly after surgery) and 1 year after surgery for 53 (100%) and 47 (88.7%) patients, respectively. Results: EUS was applied to assess the quality of all distal anastomoses, 32 target vessels, and 2 conduit trunks. Insufficient TTFM findings were obtained for 18 grafts. However, graft revision was performed for only 3 distal anastomoses; based on the EUS findings, the remaining 15 sites were not revised. The early and 1-year overall graft patency rates were 100% (141 anastomoses) and 96.1% (122 of 127 anastomoses), respectively. All 15 of the distal anastomoses that were not revised despite insufficient TTFM results were patent at the 1-year mark. Conclusion: The routine application of EUS in CABG could be beneficial by confirming the quality of surgery and reducing unnecessary procedures.

Clinical utility of endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling of pancreatic cancer

  • Nozomi Okuno;Kazuo Hara;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Daiki Fumihara;Takafumi Yanaidani
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.221-228
    • /
    • 2023
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting. Methods: CGP was attempted in 178 samples obtained from 151 consecutive patients with pancreatic cancer at the Aichi Cancer Center between October 2019 and September 2021. We evaluated the adequacy of the samples for CGP and determined the factors associated with the adequacy of the samples obtained by EUS-TA retrospectively. Results: The overall adequacy for CGP was 65.2% (116/178), which was significantly different among the four sampling methods (EUS-TA vs. surgical specimen vs. percutaneous biopsy vs. duodenal biopsy, 56.0% [61/109] vs. 80.4% [41/51] vs. 76.5% [13/17] vs. 100.0% [1/1], respectively; p=0.022). In a univariate analysis, needle gauge/type was associated with adequacy (22 G fine-needle aspiration vs. 22 G fine-needle biopsy [FNB] vs. 19 G-FNB, 33.3% (5/15) vs. 53.5% (23/43) vs. 72.5% (29/40); p=0.022). The sample adequacy of 19 G-FNB for CGP was 72.5% (29/40), and there was no significant difference between 19 G-FNB and surgical specimens (p=0.375). Conclusions: To obtain adequate samples for CGP with EUS-TA, 19 G-FNB was shown to be the best in clinical practice. However, 19 G-FNB was not still sufficient, so further efforts are required to improve adequacy for CGP.