• 제목/요약/키워드: ESPS

검색결과 25건 처리시간 0.031초

Development of Capacitance Measuring Equipment for Electrostatic Precipitator

  • Kim, Seung-Min;Lee, Sung-Jin;Nam, Jung-Han;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.128.2-128
    • /
    • 2001
  • Since pulse energization can improve the performance of Electrostatic Precipitator(ESP) for high resistivity dusts, high voltage micro-pulse generators, 70kV 140usec duration pulses for instance, are commonly developed by LC resonance for most pulse powered ESPs. Consisting of discharge electrodes and collecting electrodes, ESP has its own capacitance like a capacitor. ESP's capacitance affects the LC resonance phenomenon with resonance inductor and capacitor of micro-pulse power supply, engineers should acquire the value of their ESP to design for proper power supply design. In this study, we describe the ESP's capacitance measuring device which has the same topology with our new developed micro-pulse power supply. In this microcontroller based capacitance measuring equipment, ESP's capacitance can be calculated easily through ...

  • PDF

2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구 (Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators)

  • 유경훈;오명도;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

프로토타이핑 개발도구를 이용한 e-Car 시스템 구현 (An Implementation of e-Car System using Prototyping Development Tool)

  • 이정배;이영란;김대응;안성순;남지은;강신관
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 춘계학술발표대회
    • /
    • pp.536-538
    • /
    • 2008
  • 임베디드 시스템은 안정성이나 신뢰성이 매우 중요하고 개발 난이도가 높음에도 불구하고 상품의 개발기간을 최소화하여 시장진입시점을 빠르게 해야 하는 어려움이 있다. 프로토타이핑 개발 방법론은 그러한 임베디드 시스템 제품의 개발 비용을 최소화하고 경쟁력을 강화하기 위해 널리 이용되고 있다. 본 논문에서는 프로토타이핑 개발도구인 RapidPLUS와 ESPS(Embedded System Prototype Suit)를 이용하여 가상 프로토타이핑을 하여 자동차 시뮬레이터와 실물 프로토타입인 모형자동차를 구현한 후 무선인터넷을 이용한 원격자동차 제어 e-Car시스템을 구현하였다.

유·가스정 최적 운영을 위한 ESP의 장기 성능 진단 및 고장 예측 실험 연구 (Experimental Study on the Diagnosis and Failure Prediction for Long-term Performance of ESP to Optimize Operation in Oil and Gas Wells)

  • 이승재;최준호;이정환
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.71-78
    • /
    • 2023
  • 일반적으로 평균 수명이 1.0~1.5년인 전기식 액중형 펌프(electrical submersible pump, ESP)는 유·가스 및 저류층 특성, 운영 조건에 따라 성능 저하 및 수명 감소가 발생하며, 이에 따른 ESP의 고장은 회수 및 설치에 따른 높은 유정 개·보수(workover) 비용과 생산 중단에 따른 추가 비용이 발생한다. 이에 본 연구에서는 유·가스정에서 ESP 장기 운영에 따른 수명을 예측하고자 환형 유동 시스템(flow loop system)을 설계 및 구축하고, ESP 설치 초기 시점부터 고장 시점까지의 ESP 수명에 대한 전 주기 데이터를 취득 및 분석하였다. 구축한 시스템에서 산출되는 데이터 중 ESP의 유체유량, 흡입구 및 토출구의 온도, 압력 그리고 외측부에 설치된 진동 측정기의 데이터 분석을 통하여 ESP 장기 운영에 따른 성능 상태를 정상(normal), 권고 I (advise I), 권고 II (advise II), 유지관리(maintenance), 고장(failed)의 총 5단계로 분류하였다. 실험 결과를 통해 ESP 장기 운영시 단계별 데이터의 경향 차이를 확인하였으며, 이를 통해 운영 기간에 따른 ESP의 상태를 진단하고 펌프의 고장을 예측하였다. 본 연구를 통해 도출된 결과는 유·가스정에서 운영되는 ESP의 상태 모니터링(monitoring) 을 위한 고장 예측 프로그램 및 데이터 분석 알고리즘 개발에 활용될 수 있을 것으로 판단된다.

정보가전용 임베디드 프로토타이핑 시스템 설계 (A Design of Embedded Prototyping System for Home Appliance)

  • 이정배;이영란;정영진;김종일;김남동;신현철
    • 융합보안논문지
    • /
    • 제6권1호
    • /
    • pp.91-103
    • /
    • 2006
  • 임베디드 제품의 개발 비용과 경쟁력 강화를 위한 개발 방법론으로 널리 이용되고 있는 것이 프로토타이핑이다. 프로토타이핑에는 컴퓨터 기술을 이용한 가상 프로토타이핑과 레고 블록을 이용한 실물 프로토타이핑이 있다. 가상 프로토타이핑 환경에서는 다양한 컴포넌트와 라이브러리를 제공함으로써 정밀한 단위까지의 타겟 모델의 시뮬레이션이 가능하고 실물 프로토타이핑 환경에서는 타겟 모델의 임베디드 구동 환경에 가까운 시뮬레이션 환경을 제공하다. 하지만, 가상 프로토타이핑 환경에서는 실제 타겟 모델의 구동 환경 요소까지의 시뮬레이션이 어렵고 실물 프로토타이핑 환경에서는 다양하고 정밀한 정보가전분야의 소형 제품까지의 시뮬레이션이 어려운 실정이다. 본 논문에서는 이런 가상과 실물 프로토타이핑 환경의 단점을 보완하기 위한 통합 프로토타이핑 시스템을 위한 인터페이스를 ActiveX 컴포넌트 기술과 TCP/IP 소켓 통신 데이터 연동 인터페이스를 설계 및 구현하였다.

  • PDF

경성 실시간 제어 시스템을 위한 실물 프로토타이핑 모델 기반 개발 환경 (Physical Prototyping Model based Development Environment for Hard Real-Time Control Systems)

  • 김동훈;전상호;강순주
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2011년도 한국컴퓨터종합학술대회논문집 Vol.38 No.1(B)
    • /
    • pp.55-58
    • /
    • 2011
  • 본 논문에서는 경성 실시간 제어 시스템 개발의 어려움을 해결하고자 실물 프로토타이핑(Physical Prototyping) 기법을 적용한 임베디드 실시간 시스템 소프트웨어 개발 방법론에 적합한 개발 환경을 구현하였다. 그리고 이를 검증하기 위한 사례연구로서 두 바퀴 형태의 이동 로봇의 설계 및 구현과 실험을 통해 검증한다. 제안한 개발 환경은 크게 3 단계의 개발환경으로 구성되어 있다. 첫 번째는 타겟 시스템의 요구 분석 및 시스템 모델링을 설계하는 가상 프로토타이핑 개발 환경이다. 두 번째는 실물 프로토타이핑 모델을 설계하여 기능 및 성능에 대한 검증을 하는 실물 프로토타이핑 개발 환경이다. 마지막으로 이러한 검증 단계를 지속적으로 거치면서 점증적으로 소프트웨어를 구현하는 응용분야 적응형 점증적 프로토타이핑 개발 환경이 있다. 또한, Matlab, Simulink, 유비노스 아키텍처 및 이클립스 기반의 통합 개발 환경, ESPS 모바일 보드를 사용하여 경성 실시간 제어 시스템의 설계 및 구현, 성능 검증을 통해 제안한 개발 환경의 유효성을 입증한다.

근막통증증후군의 통증유발점 치료를 위한 멀티어레이 전극과 프로그램 가능한 다채널 전기자극기 개발 (Development of Multi-Array Electrode and Programmable Multi-channel Electrical Stimulator for Firing Trigger Point of Myofascial Pain Syndrome)

  • 김수홍;김수성;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.221-227
    • /
    • 2015
  • In this study, Multi-Array Electrodes (MAE) and Programmable Multi-channel Electrical Stimulator (PMES) were implemented for firing Trigger Points (TPs) of the patient with Myofascial Pain Syndrome (MPS). MAE has 25 Ag/AgCl electrodes arranged in the form of array ($5{\times}5$) fabricated with flexible pad, which are applicable to be easy-attached to curved specific region of the human body. PMES consisted of 25 channels. Each channel was to generate various electric stimulus patterns (ESPs) by changing the mono-phasic or bi-phasic of ESP, On/Off duration of ESP, the interval between ESP, and amplitude of ESP. PMES hardware was composed of Host PC, Stimulation Pattern Editing Program (SPEP), and Multi-channel Electrical Stimulator (MES). Experiments were performed using MAE and PMES as the following. First experiment was performed to evaluate the function for each channel of Sub- Micro Controller Unit (SMCU) in MES. Second experiment was conducted on whether ESP applied from each channel of SMCU in PMES was focused to the electrode set to the ground, after applying ESP being output from each channel of SMCU in PMES to MAE.

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Advanced Metering Infrastructure를 이용한 Consumer Portal 개발 (A Development on Consumer Portal System based on Advanced Metering Infrastructure)

  • 진성일;정남준;유인협;김선익;고종민
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1903-1909
    • /
    • 2007
  • As the electric power industry has been revolutionarily transformed such that the distributed energy resources have been interconnected with power systems and a variety of energy service providers have been appeared, the need of Consumer Energy Portal as a core of two-way communication and service infrastructure between power suppliers and consumers has been gradually increased. Consumer Energy Portal can be thought of as a combination of hardware and software enabling two-way communication between energy service providers and equipment within the consumers' premises or a physical and logical link between consumers' in-building networks and wide-area access networks. In other words, Consumer Energy Portal can make the way the power industry has been traditionally operated the web-based way, enabling two-way interactions between energy service providers and consumers and mutual networking between end users' equipment. Thus, Consumer Energy Portal can be a kind of Service portal that provides new value-added services and efficient power operations that in the past. In this paper, for ESPs' integrated resources management, demand side management and value-added service provision, we have established the two-way access network that can gather real-time metering data using ZigBee technology and control physically networked equipment.

A Study on Energy Platform Using Data in the US: Based on Opening Platform Model

  • Song, Minzheong
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.41-50
    • /
    • 2021
  • The purpose of this study is to analyze various energy platforms using data in the US and to suggest directions and implications. Some of the leading energy platforms are selected and analyzed based on the opening platform model. We focus on the case analysis of the US utility companies. In case of the horizontal open platform, Green Button sponsor's 'Connect My Data (CMD)' driven by the government invites the utility companies to jointly develop the sponsor's data solution. In case of the vertical open platform, the certification program 'Share My Data (SMD)' allows backward compatibility, because the technical improvement is minimal. The utility companies benchmark Amazon's three-sided market mediation and prefer platform and category exclusivity. For the former, they have data analytics companies like Enervee, Opower and for the latter, they have electronics manufactures and energy service providers (ESPs) like Distributed Energy Resources (DERs). Based on this US case study, we suggest the energy platforms to open their platform for renewable energy supply, energy conservation, high-efficiency products, and residential DER dissemination. To successfully implement the government's energy transition policy, the US platforms should be benchmarked as a business model. Especially, it is needed for them to coordinate a platform ecosystem. To ensure trust in the products and services offered on the marketplace platform, platform's certification program is helpful.