• 제목/요약/키워드: ESI-MS/MS

검색결과 439건 처리시간 0.026초

A Fast and Sensitive Method for the Simultaneous Determination and Quantification of Six Anionic Surfactants in Surface Water using HILIC-ESI-MS Technique

  • Dash, Upendra N.;Paul, Saroj Kumar
    • Mass Spectrometry Letters
    • /
    • 제3권3호
    • /
    • pp.78-81
    • /
    • 2012
  • The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to be used as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquatic ecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of six anionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization (ESI) mass spectrometer (MS), in the concentration range 15-20 ${\mu}g/L$. The capability of the method was established using regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with 1-dodecyl hydrogen sulfate at 15 ${\mu}g/L$. Combined efficiency of solid phase extraction and MS detection established recovery of 89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerful technique for environmental applications concerning the screening of polar contaminants.

Theoretical and Experimental 31P NMR and ESI-MS Study of Hg2+ Binding to Fenitrothion

  • Koo, In-Sun;Ali, Dildar;Yang, Ki-Yull;vanLoon, Gary W.;Buncel, Erwin
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1257-1261
    • /
    • 2009
  • We present the theoretical and experimental results of $^{31}P$ NMR and low energy CID MS/MS study of $Hg^{2+}$ binding to fenitrothion (FN). The calculated $^{31}P$ NMR chemical shifts order for FN with $Hg^{2+}$ complex is in good agreement with experimental $^{31}P$ NMR chemical shifts order. The experimental and theoretical $^{31}P$ NMR study of organophosphorus pesticide with $Hg^{2+}$ gives to important information for organophosphorus pesticide metal complexes. ESI-MS and low energy CID MS/MS experiments of $Hg^{2+}$-FN complexes combined with accurate mass measurements give insight into the metal localization and allow unambiguous identification of fragments and hydrolysis products.

Determination of Alisol B 23-acetate and Alisol C 23-acetate in Alismatis Rhizoma by HPLC-ESI-MS

  • Ahn, Mi-Jeong;Lee, Cheol-Ho;Shin, Yong-Wook;Chun, Man-Seog;Kim, Chul-Young;Kim, Jin-Woong
    • Natural Product Sciences
    • /
    • 제14권3호
    • /
    • pp.152-155
    • /
    • 2008
  • An HPLC-ESI-MS method has been developed to identify and quantify two main tetracyclic triterpenes, alisol B 23-acetate and alisol C 23-acetate in the Alismatis Rhizoma (Taeg-Sa). The relative distribution of the two triterpenes in the methanolic extract of commercially available Alismatis Rhizoma was established by selective ion monitoring (SIM) mode via electrospray ionization (ESI) source. Regression equations revealed good linear relationship, and the correlation coefficients were 0.999 and 0.998 for alisol B 23-acetate and alisol C 23-acetate, respectively, between the peak areas of the components and their concentration in a range of $0.06-2.0{\mu}g/mL$. It was found that there were significant differences in the amount of alisol B 23-acetate and alisol C 23-acetate between Korean and Chinese origins. The results showed that this method could be used to identify the two components in Alismatis Rhizoma with high sensitivity and selectivity.

Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatographyelectrospray-tandem mass spectrometry

  • Lee, Sang-Hoo;Kwon, Soon-Ho;Shin, Hye-Jin;Park, Ji-Myeong;Lim, Hwan-Sub;Lee, Kyoung-Ryul;Kim, Young-Jin
    • BMB Reports
    • /
    • 제43권11호
    • /
    • pp.761-765
    • /
    • 2010
  • Salivary testosterone levels in Korean adults were quantitatively measured for the first time by liquid chromatography-electrospray-tandem mass spectrometry (LC ESI MS/MS). Salivary testosterone was separated on a multiple reaction monitoring (MRM) chromatogram within 7 min. The LC ESI MS/MS assay was validated over the linearity range of 0.01-2.00 ng/ml (r=0.99987) using testosterone-$d_3$ as an internal standard. The lower limit of quantification (LOQ) was 0.01 ng/ml. The intra- and inter-assay precisions were 1.54% to 4.09% and 0.96% to 4.29%, respectively. The mean recovery was 93.32% (range 88.43-98.05%). The validated assay was then applied to measure the salivary testosterone levels of Korean adults. In men, the salivary testosterone level collected between 9:00-11:00 am was approximately 2.8 times higher than that in women (P < 0.0001). Salivary testosterone levels in both sexes negatively correlated with age. The present assay would also be useful in measuring salivary testosterone levels in clinical laboratories.

Analysis of erectile dysfunction drugs and their analogues in counterfeit drugs and herbal medicines by LC-ESI-MS/MS

  • Lee, Ji Hyun;Jeong, Ji Hye;Park, Hyoung-Joon;Do, Jung Ah;Heo, Seok;Cho, Sooyeul;Yoon, Chang-Yong
    • 분석과학
    • /
    • 제29권4호
    • /
    • pp.155-161
    • /
    • 2016
  • Distribution of various illegal or counterfeit drugs of seven approved erectile dysfunction drugs and their analogues has been increased, causing health problems such as cardiovascular disorder, tachycardia, headache, or vision disturbance. We used liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) to determine the erectile dysfunction drugs and their analogues in various counterfeit drugs. Eleven erectile dysfunction drugs and their analogues were detected, with sildenafil and its analogues being the most counterfeited compounds (73.8 %), followed by tadalafil and its analogues (25.4 %). The limits of detection (LOD) and the limits of quantitation (LOQ) of liquid-type and solid-type negative samples ranged from 0.1 to 3.3 ng/mL or ng/g and from 0.3 to 10.0 ng/mL or ng/g, respectively. The recoveries ranged from 84.3 to 112.3 % and 83.2 to 110.2 %, respectively. The contents of sildenafil and tadalafil in the various counterfeit drugs ranged from 21.0 to 947.5 mg/g and from 0.2 to 170.2 mg/g, respectively.

Endophytic Bacillus sp. CY22 from a Balloon Flower (Platycodon grandiflorum) Produces Surfactin Isoforms

  • Cho, Soo-Jeong;Hong, Su-Young;Kim, Jin-Young;Park, Sang-Ryeol;Kim, Min-Keun;Lim, Woo-Jin;Shin, Eun-Chule;Kim, Eun-Ju;Cho, Yong-Un;Yun, Han-Dae
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권6호
    • /
    • pp.859-865
    • /
    • 2003
  • Surfactin is a mixture of cyclic lipopeptides built from variants of a heptapeptide and a ${\beta}-hydroxy$ fatty acid produced by several strains of Bacillus sp. Surfactin isoforms produced by endophytic Bacillus sp. CY22 from a balloon flower were isolated and characterized. It was found that the purified surfactin had three isoforms with protonated masses of m/z 1,008, 1,022, and 1,036, and different structures in combination with Na, K, Ca ions using MALDI-TOF MS, ESI-MS/MS, and ICP MS, respectively. In the MS/MS analysis, the isolated surfactin had the identical amino acid sequence (LLVDLL) and hydroxy fatty acids (with 13 to 15 carbons in length), even though isolated from different Bacillus strains. The sfp22 gene, required for producing the surfactin, consisted of an open reading frame (ORF) of 675 bp encoding 224 amino acid residues with a signal peptide of 20 amino acids. The predicted amino acid sequence of sfp22 was very similar to that of Ipa-8.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

LC/ESI/MS와 GC/TOF-MS를 이용한 인체뇨시료에서의 Prostanozol 대사체 검출 (Determination of metabolites of prostanozol in human urine by LC/ESI/MS and GC/TOF-MS)

  • 염태우;팽기정;김연제
    • 분석과학
    • /
    • 제24권3호
    • /
    • pp.173-182
    • /
    • 2011
  • 약물(Prostanozol)을 복용한 여성을 대상으로 한 뇨시료 중에 함유된 Prostanozol 및 그 대사체들을 검출하기 위해 LC/ESI/MS와 GC/TOF-MS를 이용하여 효과적으로 분리 및 검출하였고, LC/ESI/MS의 질량스펙트럼으로부터는 각각의 분자량을 추정하였으며 GC/TOF-MS로는 이들을 확인하였다. M1은 Prostanozol의 17번 탄소가 케톤기로 치환된 17-keto-Prostanozol, M2는 M1에서 pyrazole nucleus 와 Aring에 한 개의 히드록시기가 치환된 hydroxy-17-keto-Prostanozol, M3는 B-ring 또는 C-ring에 한 개의 히드록시기가 치환된 hydroxy-17-keto-Prostanozol, M4는 한 개의 히드록시기가 D-ring에 치환된 hydroxy-17-keto-Prostsnozol로 확인되었으며 M5는 17번 탄소 위치에 히드록시기를 갖고 B-ring 또는 C-ring에서 하나의 히드록시기가 치환된 hydroxy-17-hydroxy-Prostanozol로 추정되며 M6은 17번 탄소 위치에 케톤기를 갖고 pyrazole nucleus 혹은 A-ring에 하나의 히드록시기를 또한 B-ring 또는 C-ring에 또 하나의 히드록시기가 치환된 dihydroxy-17-keto-Prostanozol, M7은 M6와 같이 17번 탄소에 케톤기를 갖으며 pyrazole nucleus 혹은 A-ring에 하나의 히드록시기를, 또한 D-ring에 또 하나의 히드록시기를 가진 dihydroxy-17-keto-Prostanozol로 확인되었다. 마지막으로 M8은 pyrazole nucleus 혹은 A-ring에 하나의 히드록시기를 갖고 그 외의 ring에 또 다른 히드록시기가 치환된 dihydroxy-17-hydroxy-Prostanozol임을 확인할 수 있었다. 이중 M5, M7, 그리고 M8은 지금까지 밝혀지지 않았던 새로운 대사체였다. 체내에서의 포합반응 여부를 확인한 결과 Prostanozol과 8종의 모든 대사체가 글루쿠론산 포합체를 형성하였고, 8종의 대사체 중 일부는 포합체를 형성하지 않고도 배출되며 특히 M6과 M7은 황산 포합체로도 배설되는 것을 확인할 수 있었다.

Determination of nucleosides in human urine by high-performance liquid chromatography with electrospray ionization mass spectrometry(LC/ESI-MS)

  • Lee, Sang-Hee;Jung, Byung-Hwa;Kim, Sun-Yeou;Kim, Ho-Cheol;Chung, Bong-Chul
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.290.1-290.1
    • /
    • 2003
  • Oxidative DNA damage has been associated with many disease. Quantation of DNA adducts is considered to be a useful biomarker of oxidative DNA damage because its formation can also be induced by oxidative stress. Extensive efforts have been taken to identify the analytical methods for minimizing the artifactual formation of oxidative DNA damage. We have done direct analysis of DNA adducts using LC/ESI-MS without urine sample extraction. (omitted)

  • PDF

New Dimeric Phenolic Conjugates from the Wood of Tamarix tetragyna

  • Hussein, Sahar A.M.
    • Natural Product Sciences
    • /
    • 제3권2호
    • /
    • pp.127-134
    • /
    • 1997
  • Two new dimeric phenolic conjugates, 2,3-di-O-dehydrodigallicmonocarboxyl-$({\alpha},{\beta})$-$^4C_1$-glucopyranose and ellagic acid 3,3'-dimethylether-4-0-$SO_3K$ were isolated from the debarked heart wood of Tamarix tetragyna (Tamaricaceae) along with the known phenolic compounds, isoferulic acid, ferulic acid, gallic acid, gallic acid 4-methyl ether, syringic acid, ellagic acid 3,3'-dimethyl ether and ellagic acid. All structures were determined mostly by ESI-MS, ID and 2D-NMR spectroscopy.

  • PDF