• 제목/요약/키워드: ESE lightning rods

검색결과 3건 처리시간 0.017초

일반형이 아닌 피뢰침의 설치 실태에 대한 통계적 조사 (Statistics on the Present Status of Installations of Non-conventional Lightning Rods)

  • 이복희;이석연;이수봉;백영환;이규선;김동성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.347-350
    • /
    • 2006
  • The conception of early streamers is in sufficient and inadequate as a parameter for the determination of any advantage of early streamer emission(ESE) lightning rods versus ordinary lightning rods. Thus, standards for many other national and international lightning protection as well as KS C IEC 61024-1 do not take ESE lightning rods, charge dissipation systems or non-conventional lightning rods. Unfortunately, many non-conventional lightning rods such as ESE lightning rods and charge dissipation systems in Korea are increasingly used in lightning protection of structures including explosive manufacturing buildings, electric generating, transmission and distribution systems. This study attempts to make aware of no advantage of ESE rods and other non-conventional lightning protection systems and to investigate the present status of installations of ESE lightning rods.

  • PDF

Performance Evaluation of Early Streamer Emission Lightning Air Terminal

  • Choi, Sang-Won;Her, Yong
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.18-23
    • /
    • 2006
  • Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

고전압 모의시험을 통한 피뢰침의 성능 비교평가 (Comparative Performance Evaluation of Lightning Air Terminals by the HV Laboratory Test)

  • 이재복;명성호;조연규;김점식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권12호
    • /
    • pp.627-632
    • /
    • 2001
  • There are claims that ESE(Early streamer emission) Air terminals offer a vastly increased zone of protection over that of traditional lightning rods by causing the emission of an upward streamer/leader that will propagate towards the tip of downward leader at an early stage in the attachment process than would occur for a simple rod in the same geometrical configurations. This paper shows the results of comparing test a particular type of ESE air terminals with a simple rod conducted in the KEH HV laboratory, which are lightning impulse voltage test, flashover direction test and corona emission current measurement. The results from this test show a completely random scattering of flashovers to the conventional and ESE air terminals under identical electrics] and geometrical conditions, and thus shows no advantage of one terminal over the other.

  • PDF