• Title/Summary/Keyword: ESD

Search Result 470, Processing Time 0.02 seconds

A Study on SCR-Based ESD Protection Circuit with PMOS (PMOS가 삽입된 SCR 기반의 ESD 보호 회로에 관한 연구)

  • Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1309-1313
    • /
    • 2019
  • In this paper, the electrical characteristics of Gate grounded NMOS(GGNMOS), Lateral insulated gate bipolar transistor(LIGBT), Silicon Controlled Rectifier(SCR), and Proposed ESD protection device were compared and analyzed. First, the trigger voltage and holding voltage were verified by simulating the I-V characteristic curve for each device. After that, the robustness was confirmed by HBM 4k simulation for each device. As a result of HBM 4k simulation, the maximum temperature of the proposed ESD protection device is lower than that of GGNMOS and GGLIGBT and SCR, which means that the robustness is improved, which means that the ESD protection device is excellent in terms of reliability.

Mixed-Mode Transient Analysis of HBM ESD Phenomena (HBM ESD 현상의 혼합모드 과도해석)

  • Choe, Jin-Yeong;Song, Gwang-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.1
    • /
    • pp.1-12
    • /
    • 2001
  • Based on mixed-mode transient analyses utilizing a 2-dimensional device simulator, we have suggested the methodology to analyze the HBM ESD phenomena in CMOS chips utilizing NMOS transistors for ESD protection, and have analyzes the HBM discharge mechanisms in detail. Also the second breakdown characteristics in the protection device have been successfully simulated based on mixed-mode simulations, to explain the discharge mechanisms leading to device failure. To analyze the effects of the device structure changes on the discharge characteristics, we have compared the results of DC analyses and mixed-mode transient analyses, and have discussed about more robust designs of NMOS transistor structures against HBM ESD based on the analyses.

  • PDF

Improvements of Extended Drain NMOS (EDNMOS) Device for Electrostatic Discharge (ESD) Protection of High Voltage Operating LDI Chip (고전압용 LDI 칩의 정전기 보호를 위한 EDNMOS 소자의 특성 개선)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • High current behaviors of the extended drain n-type metal-oxide-semiconductor field effects transistor (EDNMOSFET) for electrostatic discharge (ESD) protection of high voltage operating LDI (LCD Driver IC) chip are analyzed. Both the transmission line pulse (TLP) data and the thermal incorporated 2-dimensional simulation analysis demonstrate a characteristic double snapback phenomenon after triggering of biploar junction transistor (BJT) operation. Also, background doping concentration (BDC) is proven to be a critical factor to affect the high current behavior of the EDNMOS devices. The EDNMOS device with low BDC suffers from strong snapback in the high current region, which results in poor ESD protection performance and high latchup risk. However, the strong snapback can be avoided in the EDNMOS device with high BDC. This implies that both the good ESD protection performance and the latchup immunity can be realized in terms of the EDNMOS by properly controlling its BDC.

Usefulness of the S-O clip for duodenal endoscopic submucosal dissection: a propensity score-matched study

  • Ippei Tanaka;Dai Hirasawa;Hiroaki Saito;Junichi Akahira;Tomoki Matsuda
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.769-777
    • /
    • 2023
  • Background/Aims: Endoscopic submucosal dissection (ESD) for superficial non-ampullary duodenal tumors (SNADETs) is associated with a high rate of en bloc resection. However, the technique for ESD remains challenging. Recent studies have demonstrated the effectiveness of S-O clips in colonic and gastric ESD. We evaluated the efficacy and safety of duodenal ESD using an S-O clip for SNADETs. Methods: Consecutive patients who underwent ESD for SNADETs between January 2011 and December 2021 were retrospectively enrolled. Propensity score matching analysis was used to compare patients who underwent duodenal ESD with the S-O clip (S-O group) and those who underwent conventional ESD (control group). Intraoperative perforation rate was the primary outcome, while procedure time and R0 resection rate were the secondary outcomes. Results: After propensity score matching, 16 pairs were created: 43 and 17 in the S-O and control groups, respectively. The intraoperative perforation rate in the S-O group was significantly lower than that in the control group (p=0.033). A significant difference was observed in the procedure time between the S-O and control groups (39±9 vs. 82±30 minutes, respectively; p=0.003). Conclusions: The S-O clip reduced the intraoperative perforation rate and procedure time, which may be useful and effective in duodenal ESD.

A study on the design of thyristor-type ESD protection devices for RF IC's (RF IC용 싸이리스터형 정전기 보호소자 설계에 관한 연구)

  • Choi, Jin-Young;Cho, Kyu-Sang
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.172-180
    • /
    • 2003
  • Based on simulation results and accompanying analysis, we suggest a thyristor-type ESD protection device structure suitable for implementation in standard CMOS processes to reduce the parasitic capacitances added to the input nodes, which is very important in CMOS RF ICs. We compare DC breakdown characteristics of the suggested device to those of a conventional NMOS protection device to show the benefits of using the suggested device for ESD protection. The characteristic improvements are demonstrated and the corresponding mechanisms are explained based on simulations. Structure dependencies are also examined to define the optimal structure. AC simulation results are introduced to estimate the magnitude of reduction in the added parasitic capacitance when using the suggested device for ESD protection. The analysis shows a possibility of reducing the added parasitic capacitance down to about 1/40 of that resulting with a conventional NMOS protection transistor, while maintaining robustness against ESD.

  • PDF

The novel SCR-based ESD Protection Circuit with High Holding Voltage Applied for Power Clamp (파워 클램프용 높은 홀딩전압을 갖는 사이리스터 기반 새로운 구조의 ESD 보호회로)

  • Lee, Byung-Seok;Kim, Jong-Min;Byeon, Joong-Hyeok;Park, Won-Suk;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.208-213
    • /
    • 2013
  • In this paper, we proposed the novel SCR-based ESD protection circuit with high holding voltage for power clamp. In order to increase the holding voltage, the floating p+ and n+ to n-well and p-well, respectively, in the conventional SCR. The resulting increase of the holding voltage of the our proposed ESD circuit enables the high latch-up immunity. The electrical characteristics including ESD robustness of the proposed ESD circuit have been simulated using Synopsys TCAD simulator. According to the simulation result, the proposed device has higher holding voltage of 4.98 V than that of the conventional SCR protection circuit. Moreover, it is confirmed that the device could have the holding voltage of maximum 13.26 V with the size variation of floated diffusion area.

Usefulness of a new polyvinyl alcohol hydrogel (PVA-H)-based simulator for endoscopic submucosal dissection training: a pilot study

  • Dong Seok Lee;Gin Hyug Lee;Sang Gyun Kim;Kook Lae Lee;Ji Won Kim;Ji Bong Jeong;Yong Jin Jung;Hyoun Woo Kang
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.604-612
    • /
    • 2023
  • Background/Aims: We developed a new endoscopic submucosal dissection (ESD) simulator and evaluated its efficacy and realism for use training endoscopists. Methods: An ESD simulator was constructed using polyvinyl alcohol hydrogel sheets and compared to a previous ESD simulator. Between March 1, 2020, and December 30, 2021, eight expert endoscopists from three different centers analyzed the procedure-related factors of the simulator. Five trainees performed gastric ESD exercises under the guidance of these experts. Results: Although the two ESD simulators provided overall favorable outcomes in terms of ESD-related factors, the new simulator had several benefits, including better marking of the target lesion's limits (p<0.001) and overall handling (p<0.001). Trainees tested the usefulness of the new ESD simulator. The complete resection rate improved after 3 ESD training sessions (9 procedures), and the perforation rate decreased after 4 sessions (12 procedures). Conclusions: We have developed a new ESD simulator that can help beginners achieve a high level of technical experience before performing real-time ESD procedures in patients.

Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions (소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교)

  • Kang, A-Rum;Lee, In-Ja;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

The Awareness of Teachers and College Students towards Sustainable Development and Education for Sustainable Development (지속가능발전 및 지속가능발전교육에 대한 대학생과 교사들의 인식)

  • Lee Sun-Kyung;Lee Jae-Young;Lee Soon-Chul;Lee Yu-Jin;Min Gyeong-Seok;Shim Suk-Kyung;Kim Nam-Soo;Ha Kyung-Hwan
    • Hwankyungkyoyuk
    • /
    • v.19 no.1 s.29
    • /
    • pp.1-13
    • /
    • 2006
  • This study was aimed to explore the level of awareness of Korean teachers and college students towards sustainable development(SD) and education for sustainable development(ESD). A survey was conducted to understand the present status of awareness of SD and ESD among 317 college students and 625 teachers in Korea from April to May of 2005. The questionnaire included items asking whether they heard about terms such as sustainability or sustainable development, the source of information on SD, the level of understanding or the urgent task for SD in Korea. It also included questions about experiences in participating in or conducting ESD, the need for ESD, important areas in and the modality for ESD and the willingness to participate in ESD. The results showed that the level of awareness on SD among teachers was low compared to college students, who have a relatively high level of access on SD issues through textbooks and classes in high school. Interestingly, most of college students replied that they never received any ESD, even though they learned SD in class. Both the teacher and student group thought that tile priority of sustainable development should be an 'environment-related' area in the social, economical and environmental perspectives. Most of the students and teachers considered the concept of SD as 'pursuing the balance between environmental protection and economic development.' Some of the teachers recognized the concept of sustainable development in the paradigm of continuous economic development. Both groups responded that the urgent task related to sustainable development is 'environmental protection' and the 'reduction of poverty.' On the other hand, they had experiences in teaching related to natural resources, gender equity, health, human rights, climate changes and other SD issues in class, but not under the name of ESD. They also emphasized 'critical thinking and problem solving & decision-making' in education. Most of the students and teachers responded that it was needed to carry out ESD, and that the way of life for SD would be the priority. It is suggested that various pedagogy and modalities according to various target groups should be considered in providing ESD. It is necessary to use more effective strategies for ESD rather than just introducing the concept of SD. Also, it is needed to review the ESD practices of teachers and improve the quality of education within the scope of ESD.

  • PDF

Comparison of Co-registration Algorithms for TOPS SAR Image (TOPS 모드 SAR 자료의 정합기법 비교분석)

  • Kim, Sang-Wan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1143-1153
    • /
    • 2018
  • For TOPS InSAR processing, high-precision image co-registration is required. We propose an image co-registration method suitable for the TOPS mode by comparing the performance of cross correlation method, the geometric co-registration and the enhanced spectral diversity (ESD) matching algorithm based on the spectral diversity (SD) on the Sentinel-1 TOPS mode image. Using 23 pairs of interferometric pairs generated from 25 Sentinel-1 TOPS images, we applied the cross correlation (CC), geometric correction with only orbit information (GC1), geometric correction combined with iterative cross-correlation (GC2, GC3, GC4), and ESD iteration (ESD_GC, ESD_1, ESD_2). The mean of co-registration errors in azimuth direction by cross correlation and geometric matching are 0.0041 pixels and 0.0016 pixels, respectively. Although the ESD method shows the most accurate result with the error of less than 0.0005 pixels, the error of geometric co-registration is reduced to 0.001 pixels by repetition through additional cross correlation matching between the reference and resampled slave image. The ESD method is not applicable when the coherence of the burst overlap areas is low. Therefore, the geometric co-registration method through iterative processing is a suitable alternative for time series analysis using multiple SAR data or generating interferogram with long time intervals.