• Title/Summary/Keyword: EPI

Search Result 544, Processing Time 0.031 seconds

Neural Activation in the Somatosensory Cortex by Electrotactile Stimulation of the Fingers: A Human fMRI Study

  • Seok, Ji-Woo;Jang, Un-Jung;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • Objective: The aim of this study is to investigate 1) somatotopic arrangement of the second and third fingers in SI area 2) difference of neural activation in the SI area produced by stimulation with different frequencies 3) correlation between the intensity of tactile perception by different stimulus intensity and the level of brain activation measurable by means of fMRI. Background: Somatosensory cortex can obtain the information of environmental stimuli about "where" (e.g., on the left palm), "what" (e.g., a book or a dog), and "how" (e.g., scrub gently or scrub roughly) to organism. However, compared to visual sense, the neural mechanism underlying the processing of specific electrotactile stimulus is still unknown. Method: 10 right-handed subjects participated in this study. Non-painful electrotactile stimuli were delivered to two different finger tips of right hand. Functional brain images were collected from 3.0T MRI using the single-shot EPI method. The scanning parameters were as follows: TR and TE were 3000, 35ms, respectively, flip angle 60, FOV $24{\times}24cm$, matrix size $64{\times}64$, slice thickness 4mm (no gap). SPM5 was used to analyze the fMRI data. Results: Significant activations produced by the stimulation were found in the SI, SII, the subcentral gyrus, the precentral gyrus, and the insula. In all participants, statistically significant activation was observed in the contralateral SI area and the bilateral SII areas by the stimulation on the fingers but ipsilaterally dominant. The SI area representing the second finger generally located in the more lateral and inferior side than that of the third finger across all the subjects. But no difference in brain area was found for the stimulation of the fingers by different frequencies. And two typical patterns were observed on the relationship between the perceived psychological intensity and the amount of voxels in the primary sensory cortex during the stimulation. Conclusion: It was possible to discriminate the representation sites in the SI by electrotactile stimulation of digit2 and digit3. But we could not find the differences of the brain areas according to different stimulation frequencies from 3 to 300Hz. Application: The results of the study can provide a deeper understanding of somatosensory cortex and offer the information for tactile display for blinds.

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

Disturbed Functional Asymmetry of Sensorimotor Cortex in Schizophrenia: A Study with Functional Magnetic Resonance Imaging (정신분열증에서 감각운동피질의 기능적 비대칭성의 장애: 기능적 자기공명영상을 이용한 연구)

  • Ahn, Kook-Jin;Chae, Jeong-Ho;Kim, Tae;Kim, Euy-Neyng;Lee, Jee-Mun;Choi, Kyu-Ho;Hahn, Seong-Tai
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.52-57
    • /
    • 2000
  • Purpose : The purpose of this study was to investigate the pattern of cerebral response to motor tasks in patients with schizophrenia compared with normal subjects using functional MRI. Materials and methods ; Nine right handed-schizophrenic patients and six right-handed normal subjects were included. We used right hand movement as task. Series of 120 consecutive echo-planar images per section were acquired during three cycles of task and rest activations. Lateralization index of cortical response was measured and compared between patients and normal subjects. Results ; Right hand motor task was associated with greater activation in left sensorimotor cortex than the right in normal subjects. Schizophrenia patients showed relatively decreased activation in left cortex and increased activation in right cortex compared with normal subjects. In one patient, reversed lateralization was noted. Conclusion : Normal hemispheric asymmetry of cortical response to motor task was found in different pattern in schizophrenia. Our result is consistent with functional disturbance of motor circuitry in this disorder. Functional MRI will play an important role in diagnosis and research of this disorder.

  • PDF

Functional-Magnetic Resonance Imaging and Transcranial Magnetic Stimulation in a Case of Schizencephaly (뇌열 1예의 기능적 자기공명영상과 경두부 자기자극)

  • 변우목;한봉수;이재교;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.14-19
    • /
    • 2000
  • Purpose : This study was to present the functional brain mapping of both functional magnetic resonance imaging(MRI) and transcranial magnetic stimulation(TMS) in a case of schizencephaly. Materials and methods : A 28-year-old man, who had left hemiplegia and schizencephaly in right cerebral hemisphere, was exacted with both functional MRI and TMS. Motor function of left hand was decreased whereas right hand was within normal limit. For functional MRI, gradient-echo echo planar imaging($TR/TE/{\alpha}$=1.2 sec/90 msec/90) was employed. The paradigm of motor task consisted of repetitive self-paseo hand flexion-extension exercises with 1-2 Hz periods. An image set of 10 slices was repetitively acquired with 15 seconds alternating periods of task performance and rest and total 6 cycles (three ON periods and three OFF periods) were performed. In brain mapping, TMS was performed with the round magnetic stimulator (mean diameter; 90mm). The magnetic stimulation was done with 80% of maximal output. The latency and amplitude of motor evoked potential(MEP)s were obtained from both abductor pollicis brevis(APB) muscles. Results : Functional MRI revealed activation of the left primary motor cortex with flexion-extension exercises of healthy right hand. On the other hand, the left primary motor cortex, left supplementary motor cortex, and left promoter areas were activated with flexion-extension exercises of left hand. In TMS, magnetic evoked potentials were induced in no areas of right cerebral hemisphere, but in 5 areas of left corebral hemisphere from both abductor pollicis brevis. Latency, amplitude, and contour of response of the magnetic evoked potentials in both hands were similar. Conclusion : Functional MRI and TMS in a patient with schizencephaly were successfully used to localize cortical motor function. Ipsilateral motor pathway is thought to be secondary to reinforcement of the corticospinal tract of the ipsilateral motor cortex.

  • PDF

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Artificial Vision Project by Micro-Bio Technologies

  • Kim Sung June;Jung Hum;Yu Young Suk;Yu Hyeong Gon;Cho Dong il;Lee Byeong Ho;Ku Yong Sook;Kim Eun Mi;Seo Jong Mo;Kim Hyo kyum;Kim Eui tae;Paik Seung June;Yoon Il Young
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.51-78
    • /
    • 2002
  • A number of research groups worldwide are studying electronic implants that can be mounted on retinal optic nerve/visual cortex to restore vision of patients suffering from retinal degeneration. The implants consist of a neural interface made of biocompatible materials, one or more integrated circuits for stimuli generation, a camera, an image processor, and a telemetric channel. The realization of these classes of neural prosthetic devices is largely due to the explosive development of micro- and nano-electronics technologies in the late $20^{th}$ century and biotechnologies more recently. Animal experiments showed promise and some human experiments are in progress to indicate that recognition of images can be obtained and improved over time. We, at NBS-ERC of SNU, have started our own retinal implant project in 2000. We have selected polyimide as the biomaterial for an epi-retinal stimulator. In-vitro and in-vivo biocompatibility studies have been performed on the electrode arrays. We have obtained good affinity to retinal pigment epithelial cells and no harmful effect. The implant also showed very good stability and safety in rabbit eye for 12 weeks. We have also demonstrated that through proper stimulation of inner retina, meaning vision can be obtained.

  • PDF

Diagnostic Accuracy, Sensitivity, Specificity and Positive Predictive Value of Fine Needle Aspiration Cytology (FNAC) in Intra Oral Tumors

  • Gillani, Munazza;Akhtar, Farhan;Ali, Zafar;Naz, Irum;Atique, Muhammad;Khadim, Muhammad Tahir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3611-3615
    • /
    • 2012
  • Objective: The objective of this study was to establish the diagnostic accuracy, specificity and sensitivity of fine needle aspiration cytology(FNAC) for intra-oral tumors, comparing with histopathology as the gold standard. Materials and methods: Forty cases of FNA cytology from intraoral tumors was performed in AFID along with the demographic data and clinical information and then diagnosed at AFIP, Rawalpindi. Then the cytology results obtained per FNAC were compared with the histopathological biopsy results of the same lesions. The following variables were recorded for each patient: Age, gender, site of biopsy, diagnosis. The data were entered and analyzed using Open-epi version 2.0. Diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Cohen Kappa was further applied to compare the agreement between the biopsy and FNAC diagnoses. A p-value of < 0.05 was considered as statistically significant. Results: Among the total patients included in the study there were 24 males and 16 females, with a ratio of 1.5:1. Age of the patients ranged from 24 to 80 years with a mean of 52 years. A total of six sites were aspirated from the oral cavity with maximum (11) aspirates taken from alveolar ridge. The results of FNAC revealed that there were 32 malignant and 8 benign aspirates. Confirmation through histopathological analysis came for 31/32 malignant cases while one was falsely given positive for malignancy on FNAC. Among a total of 40 cases, 31(77%) cases diagnosed were found to be malignant and remaining 9(23%) were benign. The FNAC results revealed 32 malignant and 8 benign lesions. Histopathology of the subsequent surgically excised specimen showed malignant lesions in 31(77%) and benign in 9(23%) patients. As a whole, it was found that the absolute sensitivity for introral FNAC was 100% and specificity 89% with positive predictive value of 97% and negative predictive value of 100%. Conclusion: Cytological diagnosis was almost corroborative with final histopathological diagnosis in all cases, with very few exceptions, exhibiting high diagnostic accuracy.

Removing SAR Speckle Noise Based on the Edge Sharpenig Algorithm (경계선 보존을 기반으로 한 SAR 영상의 잡영 제거 알고리즘에 대한 연구)

  • 손홍규;박정환;피문희
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.3-8
    • /
    • 2003
  • 모든 SAR 영상에는 전자기파 간의 간섭으로 인한 스페클 잡영(speckle)이 존재하며, 이를 제거하는 것은 양질의 SAR 영상을 얻기 위한 필수적인 전처리 과정 중 하나라고 할 수 있다. 그러나 이러한 스페클 잡영을 제거하기 위하여 기존에 제안되었던 알고리즘은 잡영은 효과적으로 감소시키는 반면 경계선과 같은 영상의 고유 정보까지 함께 감소시키는 한계가 있었다. 따라서 본 연구에서는 SAR 영상의 경계선은 보존시키면서 영상으로부터 불필요한 잡영을 제거할 수 있는 알고리즘을 구현하고, 기존의 알고리즘과 비교하여 그 효율성을 평가하고자 한다. 영상의 통계적 특성에 근거하는 기존의 알고리즘과는 달리 웨이블렛 변환(Wavelet transform)으로 경계선 및 특징 정보의 여부를 판별한 후 평균 필터(mean filter)를 적용하는 경계선 보존(edge sharpening) 알고리즘은 경계 정보의 신뢰성을 향상시킬 수 있으며, 1차원 필터를 수평, 수직, 대각선, 역대각선 방향으로 적용함으로써 하나의 영상소를 중심으로 모든 방향에 대한 경계선 여부를 확인할 수 있는 장점이 있다. 본 연구에서는 512 × 512로 절취한 1-look SAR 영상에 대하여 창 크기 5 × 5의 경계선 보존 필터를 적용하고 동일영상에 대하여 기존의 Lee, Kuan, Frost 필터 등의 실험결과를 비교함으로써 그 적합성을 판단하고자 하였다. 실험결과에 대한 수치적인 평가는 ①정규화 평균을 이용하여 평균값의 보존 여부, ②편차 계수를 이용한 스페클 잡영의 제거 여부, ③경계선 보존지수(EPI)를 이용한 경계선의 보존 정도를 통해 이루어졌다. 본 연구의 실험결과를 통해 경계선 보존 필터는 평균값의 보존 여부 및 스페클 잡영 제거 정도에 있어 다른 필터들과 큰 차이가 없지만 경계선보존지수는 다른 필터들에 비하여 가장 우수함을 확인할 수 있었다.rbon 탐식효율을 조사한 결과 B, D 및 E 분획에서 유의적인 효과를 나타내었다. 이상의 결과를 종합해볼 때, ${\beta}$-glucan은 고용량일 때 직접적으로 또는 $IFN-{\gamma}$ 존재시에는 저용량에서도 복강 큰 포식세로를 활성화시킬 뿐 아니라, 탐식효율도 높임으로써 면역기능을 증진 시키는 것으로 나타났고, 그 효과는 crude ${\beta}$-glucan의 추출조건에 따라 달라지는 것을 알 수 있었다.eveloped. Design concepts and control methods of a new crane will be introduced in this paper.and momentum balance was applied to the fluid field of bundle. while the movement of′ individual material was taken into account. The constitutive model relating the surface force and the deformation of bundle was introduced by considering a representative prodedure that stands for the bundle movement. Then a fundamental equations system could be simplified considering a steady state of the process. On the basis of the simplified model, the simulation was performed and the results could be confirmed by the experiments under various conditions.뢰, 결속 등 다차원

  • PDF

A Study of Whiter Matter Fiber Tractography in Young Internet Addiction Disorder using a Brain Diffusion Tensor Magnetic Resonance Imaging (뇌 확산텐서 자기공명영상을 이용한 청소년 인터넷 중독자의 백질 섬유로에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2016
  • The goal of this study is to investigate corpus callosum and both internal capsule changes with the internet addiction disorder compared to control group using MR diffusion tensor imaging. A total of 22 teenager volunteers who had 10 high-risk group with internet addiction and 12 normal control group were conducted for this study. Imaging was conducted on a 3 T using a EPI sequence. Image evaluation was analysed of the FA, ADC($10^{-3}mm^2/s$), length(mm). We did select ROI for image tracking on corpus callosum of 5 and including 2(internal capsule). The data from these ROIs were compared statistically among the groups using independent t-test, correlation coefficient. There were significant inter-group differences(p<0.05) among FA, ADC($10^{-3}mm^2/s$) and length(mm). And also significantly negative correlations were fond between FA values of corpus callosum and IAD scale(p=0.000). DTI was shown significant changes of FA and ADC, LNF values in IAD compared to control group. Therefore, our results may provided clinical information for brain wite matter functions.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF