• Title/Summary/Keyword: ENG structure

Search Result 2,002, Processing Time 0.031 seconds

A New Structure of Triode-type CNT-FEAs for Enhanced Electron Emission and Beam Focusing

  • Jun, Pil-Goo;Kwak, Byung-Hwak;Noh, Hyung-Wook;Lee, Soo-Myun;Uh, Hyung-Soo;Park, Sang-Sik;Ko, Sung-Woo;Cho, Euo-Sik;Lee, Jong-Duk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.456-458
    • /
    • 2004
  • We proposed a novel triode-type carbon nanotube field emitter arrays in which extracted gate is surrounded by CNT emitters. We carried out 3-dimensional numerical calculations of electrostatic potential for the proposed CNT-FEAs using the finite element method and compared the results with those obtained from the structure of conventional CNT-FEAs. It was found that the proposed structure could reduce the turn-on voltage for electron emission and improve beam focusing.

  • PDF

FORM Reliability-based Resistance Factors for Driven Steel Pipe Piles (FORM 신뢰성 기반 항타강관말뚝 저항계수 산정)

  • Park, Jae-Hyun;Huh, Jung-Won;Lee, Ju-Hyung;Chung, Moon-Kyung;Kwak, Ki-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.779-783
    • /
    • 2008
  • LRFD Resistance factors for static bearing capacity of driven steel pipe piles were calibrated in the freamework of reliability theory. Reliability analysis was performed by the First Order Reliability Method (FORM) using resistance bias factor statistics.The target reliability indices are selected as 2.0 and 2.33 for group pile case and 2.5 for single pile case, based on the reliability level of the current design practice and considering redundancy of pile group, acceptable risk level, construction quality control, and significance of individual structure.

  • PDF

Trajectory control of direct drive robot using two-degrees-of-freedom compensator

  • Shin, Jeong-Ho;Fujiune, Kenji;Suzuki, Tatsuya;Okuma, Shigeru;Yamada, Koji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.422-427
    • /
    • 1994
  • In this paper, we propose a new design approach of a two-degrees-of-freedom compensator which assures the robust stability. First of all, we clarify the internal structure of the generalized two-degrees-of-freedom compensator. By adopting this structure, we can make a bridge between the generalized controller and the disturbance observer based controller, Secondly, based on the clarified structure we derive a robust stability condition, and propose a design algorithm of free parameter taking the condition into account. The proposed design algorithm is easy to implement and, as a result, we obtain lower order free parameter then that of the conventional design algorithm.. Thirdly, we show by adopting an appropriate coprime factorization that the clarified structure can also be regarded as an extended version of the conventional PID compensator. Finally, we apply the proposed algorithm to a three-degrees-of freedom direct drive robot, and show some experimental results to verify the effectiveness of the proposed algorithm.

  • PDF

Vibration measurement and vulnerability analysis of a power plant cooling system

  • Anil, Ozgur;Akbas, Sami Oguzhan;Kantar, Erkan;Gel, A. Cem
    • Smart Structures and Systems
    • /
    • v.11 no.2
    • /
    • pp.199-215
    • /
    • 2013
  • During the service life of a structure, design complications and unexpected events may induce unforeseen vibrations. These vibrations can be generated by malfunctioning machinery or machines that are modified or placed without considering the original structural design because of a change in the intended use of the structure. Significant vibrations occurred at a natural gas plant cooling structure during its operation due to cavitation effect within the hydraulic system. This study presents findings obtained from the in-situ vibration measurements and following finite-element analyses of the cooling structure. Comments are made on the updated performance level and damage state of the structure using the results of these measurements and corresponding numerical analyses. An attempt was also made to assess the applicability of traditional displacement-based vulnerability estimation methods in the health monitoring of structures under vibrations with a character different from those due to seismic excitations.

The Thermal and Optical Properties of Te-based Antireflection structure for Optical Recording (광기록을 위한 Te-based Antireflection구조의 열적, 광학적 특성)

  • Lee, S.J.;Lee, H.Y.;Chung, H.J.;Lee, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1256-1258
    • /
    • 1993
  • Optical data storage offer high density storage and archival storage capability. In this study, we selected the ablation mechanism-one of an irreversible recording system-using the antireflection trilayer(ART) structure. Optical recording medium is a $(Te_{86}Se_{14})_{50}Bi_{50}$ thin films. Actually, ART structure is fabricated and compared to monolayer structure. ART structure leads to the reduction of recording power as well as an increase in the effciency compared to the monolayer structure.

  • PDF

Transflective IPS LCD with Multi-Domain Structures

  • Park, Kyoung-Ho;Ko, Young-Jo;Kim, Jung-Hyoung;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.895-898
    • /
    • 2004
  • We propose configurations for a transflective in-plane switching (IPS) cell using muti-domain structures. Usually, the cell configurations for a transflective liquid crystal(LC) cell have a complicated structure, because retardation change of transmissive part and reflective part are not same. The transflective LC cell should have two configurations for each part, such as a multi-cell gap structure. With the ion-beam alignment and the horizontal switching LC cell, a simple structure for a transflective LC cell is proposed. The configuration only adopts one cell gap structure, which may help the enhancement of a yield. Their original optical properties in conventional transmissive and reflective type IPS liquid crystal dispaly(LCD) are kept, it shows the wide-viewing angle and the good wavelength dispersion characteristics.

  • PDF

The Structure and Parameter Optimization of the Fuzzy-Neuro Controller (퍼지 신경망 제어기의 구조 및 매개 변수 최적화)

  • Chang, Wook;Kwon, Oh-Kook;Joo, Young-Hoon;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.739-742
    • /
    • 1997
  • This paper proposes the structure and parameter optimization technique of fuzzy neural networks using genetic algorithm. Fuzzy neural network has advantages of both the fuzzy inference system and neural network. The determination of the optimal parameters and structure of the fuzzy neural networks, however, requires special efforts. To solve these problems, we propose a new learning method for optimization of fuzzy neural networks using genetic algorithm. It can optimize the structure and parameters of the entire fuzzy neural network globally. Numerical example is provided to show the advantages of the proposed method.

  • PDF

The study on the electrical and optical characteristics of a new structure for color AC plasma display (AC-PDP의 새로운 셀구조와 그 전기 광학적 특성에 관한 연구)

  • Park, Jae-Moon;Kim, Young-Kee;Lee, Jae-Young;Shin, Joong-Hong;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.128-130
    • /
    • 2000
  • A new type ac plasma display panels(PDPs) cells are designed and tested electrically and optically. One cells have the structure of sin discharge path shape and small electrode area. The other cells have the non-symmetric structure with a same electrode area. They show a higher luminous efficienccy and a lower power consumption about 30% improvement than the conventional standard ac PDP cells.

  • PDF

The study on the electrical and optical characteristics of a new structure for color ac plasma displays(II) (새로운 전극구조를 가진 AC-PDP의 전기 광학적 특성에 관한 연구(II))

  • Lee, Woo-Geun;Lee, Jae-Young;Kim, Young-Dae;Lee, Ki-Beum;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1093-1095
    • /
    • 1999
  • A new type ac plasma display panels(PDPs) cells are designed and tested electrically and optically. One cells have the structure of sin discharge path shape and small electrode area. The other cells have the non-symmetric structure with a same electrode area. They show a higher luminous efficiency and a lower power consumption about 25% improvement than the conventional standard ac PDP cells.

  • PDF

The study on the electrical and optical characteristics of a new structure for color ac plasma displays (새로운 전극구조를 가진 ac-PDP의 전기 광학적 특성에 관한 연구 (II))

  • Ko, Ji-Sung;Lee, Woo-Geun;Lee, Jae-Young;Park, Jae-Moon;Cho, Jung-Soo;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2230-2232
    • /
    • 1999
  • A new type ac plasma display panel(PDP) cells are designed and tested electrically and optically. One cell has the structure of sin discharge path shape and small electrode area. The other cells have the non-symmetric structure with a same electrode area. They show a higher luminous efficienccy and a lower power consumption about 25% improvement than the conventional standard ac PDP cells.

  • PDF