• Title/Summary/Keyword: ENERGY EFFICIENCY

Search Result 11,076, Processing Time 0.039 seconds

Case Studies of best practices through Energy audit (에너지진단 우수 사례소개)

  • Um, Chul-Jun;Song, Euy;Kim, Chun-Yong;Kim, Doo-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.505-510
    • /
    • 2008
  • Improving energy efficiency is the important thing of energy saving strategies that was shown up result of IEA meeting and the G8 Summit. Energy audit was started in 2006 that Korea government policy for improving energy efficiency. Who used over 2,000toe/yr(tons of oil equivalent per year) energy consumption has to perform energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. This case studies are chosen to best practices by KEMCO. This studies present efficient recommendation methods for improving system performance.

  • PDF

An Analysis on the Causal Relation Between Electricity Consumption and GDP by industries in KOREA (한국의 산업별 전력소비와 경제성장간 인과관계 분석)

  • Park, Min Hyug;Roh, Geon Ki;Lee, Seung Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.39-45
    • /
    • 2016
  • In these days global energy policy is changed from "supply" to "demand". In this regards, there are needs to analysis on effect of policy such as energy efficiency strategy, electricity rates. This study examines the relationship between energy consumption reduced by new energy policy and GDP growth for each industrial sector for Korea from 1970 to 2013. With respect to the direction of causality, energy use of 1th industry like agriculture and mining leads to GDP growth. On the other hand, GDP growth of 2nd industry, manufacturing, leads to energy use. And there is bidirectional causality in 3rd industry, service sector. These findings imply that the government policies aimed at reducing electricity consumptions and increasing energy efficiency should be progressed cautiously depend on status of each industry condition.

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

Gas and particle removal characteristics of a novel electrostatic precipitation type air cleaner using an activated carbon filter as an electrode (활성탄 섬유 필터를 전극으로 활용한 정전 방식의 공기정화장치의 가스 및 입자 제거 특성 분석)

  • Lim, Gi-Taek;Kim, Yong-Jin;Han, Bangwoo;Woo, Chang Gyu;Shin, Weon Gyu;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • We have developed an electrostatic precipitation (ESP) type air cleaner for indoor air quality and investigated its performances regarding CADR (Clean air delivery rate), single-pass efficiency and gas removal efficiency. The ESP air cleaner used an ACF (Activated carbon fiber) filter for gas removal and the ACF as a high voltage electrode for particle removal. The ESP air cleaner was tested in a chamber with the volume of $1m^3$ regarding CADR and gas removal efficiency. The applied CADR area of the ESP was $1.8m^2$. Gas removal efficiency was tested with 3 gases (Acetaldehyde, Acetic acid, Ammonia). As the results of the gas removal efficiency, the ESP air cleaner shows the removal efficiencies of 90, 98 and 85% for acetaldehyde, acetic acid and ammonia, respectively.

Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors (태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가)

  • Ko, Myeong-Jin;Lim, Bo-Min;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

Performance Analysis of Wireless Communication Systems Using Deep Learning Based Transmit Power Control in Nakagami Fading Channels (나카가미 페이딩 채널에서 딥러닝 기반 송신 전력 제어 기법을 이용하는 무선통신 시스템에 대한 성능 분석)

  • Kim, Donghyeon;Kim, Dongyon;Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.6
    • /
    • pp.744-750
    • /
    • 2020
  • In this paper, we propose a deep learning based transmit power control (TPC) scheme to improve the spectral and energy efficiency of wireless communication systems. In the wireless communication system, the positions of multiple transceivers follow a uniform distribution, and the performances of spectral and energy efficiency for the proposed TPC scheme are analyzed assuming the Nakagami fading channels. The proposed TPC scheme uses batch normalization to improve spectral and energy efficiency in deep learning based training. Through simulation, we compare the results of the spectral and energy efficiency of the proposed TPC scheme and the conventional one for various area sizes that limit the position range of the transceivers and Nakagami fading factors. Comparing the performance results, we verify that the proposed scheme provides better performance than the conventional one.

Development of Control Method for Improving Energy Efficiency of Unmanned Underwater Gliders (무인 수중글라이더의 에너지 효율 개선을 위한 제어방법 개발)

  • La, Seung-kyu;Ko, Sung-hyup;Ji, Dae-hyeong;Chon, Seung-jae;Jeong, Seong-hoon;Choi, Hyeung-sik;Kim, Joon-young
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.105-112
    • /
    • 2022
  • In this paper, unmanned underwater glider was designed for high-depth operation and adopted a bladder-type buoyancy controller for improving battery efficiency, and the motion controller controls the pitch angle by moving the internal mass battery. To improve the energy efficiency of the unmanned underwater glider, a layered PID controller that performs control by section was designed. Simulation program including 6-DOF motion equations and hydrodynamics coefficients of an unmanned underwater glider is constructed using Matlab/Simulink program. Control methods such as PID controller, sliding mode controller and layered PID controller were applied to the simulator to compare the dynamics performance and energy efficiency. As a result, the layered PID controller showed improved control performance compared to other controllers and improved energy efficiency of approximately 7.2% compared to PID controller.

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

A Case Study on the post-monitoring programs under the energy efficiency labeling program (주요국의 에너지효율등급제 사후관리 사례 분석)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.58-65
    • /
    • 2014
  • The study examined the post-monitoring programs under the energy efficiency labeling program in developed countries. This study suggests a few solutions to improve the post-monitoring activities under the program. First, samples should be selected from each category for the post-monitoring activities, taking account of the consumer's continuous buying behavior. Second, it is necessary to check of detailed label contents and to perform the frequent monitoring the reinforcement of the measurement of items which have violated labeling more than once over the past few years. Last, this study suggests that the entire post-monitoring process should be disclosed and be posted on the websites on the internet in general.

The Effect of Acoustic Energy on the Collection Efficiency of the Electrostatic Precipitator (음파에너지가 전기 집진기의 집진 효율에 미치는 영향)

  • 정상현;홍원석;김용진;심성훈
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.207-215
    • /
    • 2003
  • An experimental study on the characteristics of collection efficiency for electrostatic precipitator under the action of acoustic energy in the gas stream was performed. In the experiment, the acoustic energy which has 2 kHz and 141 dB was applied to electrostatic precipitator inlet, and the test parameters were used in terms of the magnitude of gas velocity. From the results of experiment, the collection efficiency of ESP was increased due to acoustic energy, and this effect was much clearer at high velocity. This means that the acoustic energy can play an important role in the enlargement of specific collection area of the electrostatic precipitator.