• Title/Summary/Keyword: ENERGY EFFICIENCY

Search Result 11,076, Processing Time 0.056 seconds

Design of spectrum spreading technique applied to DVB-S2

  • Kim, Pan-Soo;Chang, Dae-Ig;Lee, Ho-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.22-28
    • /
    • 2007
  • Spectrum spreading, in its general form, can be conceived as an artificial expansion of the signal bandwidth with respect to the minimum Nyquist band required to transmit the desired information. Spreading can be functional to several objectives, including resilience to interference and jammers and reduction of power spectral density levels. In the paper, signal spreading is manly used for increasing the received energy, thus satisfying link budget constraints, for terminals with low aperture antennas, without increasing the transmitted EIRP. As a matter of fact, in many mobile scenarios, even when MODCOD configurations with very low spectral efficiency (i.e. QPSK-1/4) in DVB-S2 standard, are used, the link budget cannot be closed. Spectrum spreading has been recently proposed as a technique to improve system performance without introducing additional MODCOD configurations under the constraint of fixed power spectrum density level at the transmitter side. To this aim, the design of spectrum spreading techniques shall keep into consideration requirements such as spectrum mask, physical layer performance, link budget, hardware reuse, robustness, complexity, and backward compliance with existing commercial equipments. The proposed implementation allows to fully reuse the standard DVB-S2 circuitry and is inserted as an 'inner layer' in the standard DVB-S2 chain.

  • PDF

A Study on the Technological and Environmental Factors Affecting the Accuracy of Beacon Based Indoor Positioning System (기술적, 환경적 요소에 따른 비콘 기반 실내 측위 정확도 변화연구)

  • Byeon, Tae-Woo;Jang, Seong-Yong
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.2
    • /
    • pp.21-29
    • /
    • 2016
  • Indoor location system has been used Wi-Fi to get a location. After the development of BLE(Bluetooth Low Energy), the interest in the method of a indoor positioning had been move on. It has more advantages than using Wi-Fi. Easy installation, low power consumption, low signal interference and changeable setting(Advertising interval, tx power, etc.). These things can improve efficiency or accuracy in a indoor positioning system. For this reason, recent indoor positioning system uses BLE rather than Wi-Fi. Accordingly, error factors of BLE beacon based indoor positioning should be studying for high accuracy of indoor positioning. In this research, set up few experiment scenarios and keep a close watch on how technological, environmental factor is affecting positioning accuracy. When a application uses largest signal strength to get the indoor location, the mean error of experimental results was decreased compare to using received signal strength in real-time. The result was same when the application applied average and standard deviation to get the indoor location. Changing advertising interval had an effect on the mean error of indoor positioning. Short advertising interval makes the lower mean error than large advertising interval.

Application of High-performance Jet Loop Reactor for the Decolorization of Reactive black 5 and Mineralization of Oxalic Acid by Ozone (색도물질과 옥살산의 오존분해를 위한 고효율 Jet Loop 반응기의 적용)

  • Byun, Seok-jong;Geissen, Sven-Uwe;Vogelpohl, Aflons;Cho, Soon-haing;Yoon, Je-yong;Kim, Soo-Myung
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.78-85
    • /
    • 2004
  • As an ozone contactor, we newly adopted HJLR (High-performance Jet Loop Reactor) for the decolorization of Reactive black 5 and the mineralization of oxalic acid, which has been applied exclusively in biological wastewater treatments and well-known for high oxygen transfer characteristics. The ozonation efficiency for organic removals and ozone utilization depending on the mass transfer rate were compared to those of Stirred bubble column reactor, which was controlled by varing energy input in the HJLR and Stirred bubble column reactor. The results were as follows; first, the decolorization rate of Reactive black 5 in the HJLR reactor was nearly proportional to the increasing $k_La$. When the $k_La$ was increased by 25 % from $13.0hr^{-1}$ to $16.4hr^{-1}$, 30 % of the k' (apparent reaction rate constant) was increased from 0.1966 to $0.2665min^{-1}$ (Stirred bubble column; from 0.1790 to $0.2564min^{-1}$). Ozone transfer was found to be a rate-determining step in decolorizing Reactive black 5, which was supported by that no residual ozone was detected in all of the experiments. Second, the mineralization of oxalic acid was not always proportional to the increasing $k_La$ in the RJLR reactor. The rate-determining step for this reaction was OH(OH radical) production with ozone transfer, because residual ozone was always detected during the ozonation of oxalic acid in contrast with Reactive black 5. This result indicates that the increase of $k_La$ in the HJLR reactor is beneficial only when there are in ozone transfer limited regions. In addition, regardless of $k_La$, the mineralization of oxalic acid was nearly accomplished within 60 minutes. It was interpreted as that the longer staying of residual ozone by whirling liquid in the HJLR reactor contributed to an high ozone utilization(83-94%), producing more OR radicals.

Comparison of Endovenous Treatment Using a 980 nm Diode Laser versus Conventional Stripping for Truncal Saphenous Vein Incompetence: Mid-term Results by VCSS Score and Recurrence (복재정맥 부전에 대한 980-nm 다이오드 레이저를 이용한 치료와 전통적인 발거술 간의 비교: VCSS 점수와 재발에 의한 중기 임상 결과)

  • Choi, Jae-Sung;Kim, Eung-Joong;Lee, Jeong-Sang
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.387-393
    • /
    • 2010
  • Background: The aims of the present study were to assess and compare mid-term clinical outcomes including recurrences between endovenous laser therapy (EVLT) and stripping. Material and Method: Between January 2007 and February 2010, 318 limbs in 237 patients with saphenous truncal varicosities were treated by laser energy using a 980 nm diode or were treated with conventional stripping. At the initial visit and at 1, 2, 6, 12, 18, 24, and 36 months postoperatively, clinical examination and questioning for Venous Clinical Severity Score (VCSS) as well as duplex ultrasonography were done. In order to compare clinical outcomes between the two treatment groups, EVLT versus stripping, all data were processed and analyzed. Result: There were no significant differences between the two treatment groups in the extent of the reflux and the number of insufficient perforating veins. The in EVLT and the stripping group at 12 months were $90.3{\pm}4.5%$ and $93.9{\pm}4.2%$, respectively (p>0.05). Total recurrence rates were 4.4% in the EVLT group and 1.5% in the stripping group (p>0.05). In both groups, the VCSS scores were significantly reduced at week 1, 1 month, and 2 months after EVLT or stripping (p<0.001). Conclusion: Efficiency in eliminating truncal saphenous vein incompetence and reducing venous clinical severity were equal in the two treatment groups.

A Study on the Effects of Urban Public Transportation Retrofitting for Sustainability (지속가능성을 위한 도시 대중교통 레트로핏(Retrofitting) 효과분석)

  • KIM, Seunghyun;NA, Sungyoung;KIM, Jooyoung;LEE, Seungjae
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.1
    • /
    • pp.23-37
    • /
    • 2018
  • In recent years, it is very difficult to construct and expand new infrastructures in a city center because of long-term low growth and lack of space due to urban overcrowding. So, there is a need to study a variety of Retrofitting techniques and urban applications that can lead to sustainable development while efficiently utilizing existing facilities. 'Retrofit' means a sustainable urban retrofitting as a directed alteration of the structures, formations and systems of existing facilities to improve energy, water and waste efficiencies. In this study, we applied a hierarchical network design technique that can reflect the structural hierarchy of a city to study how to retrofit public transportation routes in Seoul. The hierarchical network design means dividing the hierarchy according to the functions of hubs and connecting different hierarchies to form a hierarchical network. As a result of comparing the application results of various retrofitting scenarios of public transport, the differences of daily PKT and PHT by about 2.6~3.2% less than before the improvement address that the convenience of passengers is increased. Therefore, it is expected that if the route planning is established according to the proposed method, it will increase the number of passengers and the operational efficiency by the improved convenience of public transit passengers.

Establishment of Callus Induction and Plant Regeneration System from Mature Seeds of Miscanthus sinensis (억새(Miscanthus sinensis) 성숙 종자로부터의 캘러스 유도 및 식물체 재분화 체계 확립)

  • Cho, Joon-Hyeong;Byeon, Ji-Hui
    • Korean Journal of Plant Resources
    • /
    • v.24 no.5
    • /
    • pp.628-635
    • /
    • 2011
  • This study was conducted to establish the tissue culture system for Korean domestic Miscanthus sinensis, which is used in various purposes such as forage, and bio-energy resources. With the mature seed of Miscanthus, optimum concentrations of plant growth regulators were identified for an efficient callus induction and regeneration. Among the treatments of 1~10 $mg{\cdot}L^{-1}$ 2,4-D, IBA, or NAA, callus induction rate was highest (85.3%) on MS medium containing 5 $mg{\cdot}L^{-1}$ 2,4-D. Under the condition, the callus were efficiently induced and proliferated with comparably lower frequencies of callus browning. In shoot regeneration, the treatment of NAA combined with BAP seemed to contribute more efficient conditions to shoot regeneration than those of NAA with Kinetin or 2-iP. Especially, regeneration efficiency and number of regenerated plants were 83.7% and 5.5 in 3 $mg{\cdot}L^{-1}$ NAA with 5 $mg{\cdot}L^{-1}$ BAP, respectively, which were higher frequencies than those in NAA with Kinetin or 2-iP. In results, 5 $mg{\cdot}L^{-1}$ 2,4-D and 3 $mg{\cdot}L^{-1}$ NAA combined with 5 $mg{\cdot}L^{-1}$ BAP were efficient for embryogenic callus induction and regeneration of Miscanthus. This system would be useful for mass-propagation and developing new cultivars via tissue culture of Miscanthus sinensis.

Power Reduction of Multi-Carrier Transmission System by Using Multi-Dimensional Constellation Mappings (효율적 다차원 성상도를 이용한 다중 반송파 전송 시스템의 전력 감소법)

  • Lee, Kyoung-Won;Kim, Jang-Hyun;Kim, Dae-Jin
    • Journal of Broadcast Engineering
    • /
    • v.14 no.6
    • /
    • pp.733-741
    • /
    • 2009
  • The design rule of digital communication systems is the reliable data transmission with high spectral efficiency and minimum allowable power. This paper suggests the method that saves the average power by implementing a multi-dimensional constellation in case of multi-carrier communication system. By using multi-dimensional constellations we can relocate constellation points in the form of a sphere. If we simply convert the two-dimensional QAM modulation into multi-dimensional QAM, constellation points of 2 N dimensional cube form are made up. Relocating outermost constellation points of 2 N dimensional cube form into low energy constellation points, the constellation of the 2 N-dimensional sphere form is made up which decreases power consumption. In this paper, the multi-dimensional constellations of 2 N-dimensional sphere form are designed from 16-QAM to 2,048-QAM, and power reductions are obtained by comparing constellations of 2-dimensional QAMs and multi-dimensional constellations of 2 N-dimensional sphere form. The result shows that the average power consumption of higher dimensional constellations increases, because the more a dimension elevates, the more the relocatable constellation points increase. But, the increment of the average power savings decreases as the a dimension elevates. The transmission of the data by using multi-dimensional constellations of the sphere form is effective to save the average power consumption with little hardware complexity.

An Efficient Addressing Scheme Using (x, y) Coordinates in Environments of Smart Grid (스마트 그리드 환경에서 (x, y) 좌표값을 이용한 효율적인 주소 할당 방법)

  • Cho, Yang-Hyun;Lim, Song-Bin;Kim, Gyung-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.61-69
    • /
    • 2012
  • Smart Grid is the next-generation intelligent power grid that maximizes energy efficiency with the convergence of IT technologies and the existing power grid. Smart Grid is created solution for standardization and interoperability. Smart Grid industry enables consumers to check power rates in real time for active power consumption. It also enables suppliers to measure their expected power generation load, which stabilizes the operation of the power system. Smart industy was ecolved actively cause Wireless communication is being considered for AMI system and wireless communication using ZigBee sensor has been applied in various industly. In this paper, we proposed efficient addressing scheme for improving the performance of the routing algorithm using ZigBee in Smart Grid environment. A distributed address allocation scheme used an existing algorithm has wasted address space. Therefore proposing x, y coordinate axes from divide address space of 16 bit to solve this problem. Each node was reduced not only bitwise but also multi hop using the coordinate axes while routing than Cskip algorithm. I compared the performance between the standard and the proposed mechanism through the numerical analysis. Simulation verify performance about decrease averaging multi hop count that compare proposing algorithm and another. The numerical analysis results show that proposed algorithm reduce multi hop than ZigBee distributed address assignment and another.

Power Factor Compensation System based on Voltage-controlled Method for 3-phase 4-wire Power System (3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템)

  • Park, Chul-woo;Lee, Hyun-woo;Park, Young-kyun;Joung, Sanghyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.107-114
    • /
    • 2017
  • In this paper, a novel power factor compensation system based on voltage-controlled method is proposed for 3-phase 4-wire power system. The proposed voltage-controlled power factor compensation system generates a reactive power required for compensation by applying a variable output voltage by a slidac to a capacitor. In conventional power factor compensation system using the capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limited capacity of the capacitors. However, the proposed system compensates the power factor up to 100% without error. In this paper, we have developed a voltage-controlled power factor compensation system and a control algorithm for 3-phase 4-wire power system, and verify its performance through simulation and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Fabrication and Performance of Microcolumnar CsI:Tl onto Silicon Photomultiplier (실리콘광증배관 기반의 미세기둥 구조 CsI:Tl 제작 및 평가)

  • Park, Chan-Jong;Kim, Ki-Dam;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.337-343
    • /
    • 2016
  • This study conducted the gamma ray spectroscopic analysis of the microcolumnar CsI:Tl deposited onto the SiPMs using thermal evaporation deposition. The SEM measured thickness of microcolumnar CsI:Tl and of its individual columns. From the SEM observation, the measured thickness of CsI:Tl were $450{\mu}m$ and $600{\mu}m$. The gamma ray spectroscopic properties of microcolumnar CsI:Tl, $450{\mu}m$ and $600{\mu}m$ thick deposited onto the SiPMs were analyzed using standard gamma ray sources $^{133}Ba$ and $^{137}Cs$. The spectroscopic analysis of microcolumnar CsI:Tl deposited onto the SiPMs included the measurements of response linearity over the $^{137}Cs$ gamma ray intensity; and gamma ray energy spectrum. Furthermore from the gamma ray spectrum measurement of $^{133}Ba$ and $^{137}Cs$, $450{\mu}m$ thick CsI:Tl showed good efficiency when measured with $^{133}Ba$ and $600{\mu}m$ thick CsI:Tl was highly efficient when measured with $^{137}Cs$.