• Title/Summary/Keyword: EMI Noise

Search Result 251, Processing Time 0.031 seconds

Dimming Control System Using Power Line Communication (전력선 통신을 이용한 조광 제어 시스템)

  • 박종연;주병훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.632-637
    • /
    • 2000
  • In this paper, to control with light dimming levels of the fluorescent lamps, we have used the power line instead of the signal line to transmit the control signals. To reduce the BER(Bit Error Rate) on the power line communication with the serious noise interferences. We have adapted the FSK(Frequency Shift Keying) modulation and demodulation technique. Since the electronic ballast produced the EMI(ElctroMagnetic Interference) noise in some frequency bands, we have reduced the EMI levels in the band below -50dB. By varying the switching frequency of the ballast for the FL032/T8 from 18kHz to 25kHz, it is possible that the dimming levels are controled with the range of 5∼100%

  • PDF

EMI Minimization Circuits for a High Speed Embedded Processor (고속 Embedded Processor에서 EMI 최소화 회로)

  • Kim, Sung-Sik;Cheong, Eui-Seok;Cho, Kyoung-Rok
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.1
    • /
    • pp.12-21
    • /
    • 1999
  • All kinds of electronic machinery including portable communication system are being smaller size and are used at high frequency. It generates a lot of unwanted noise signals called electromagnetic interface (EMI). This paper presents an analysis result of EMI generation in VLSI and propose new circuits to minimize of EMI using I/O driver with parallel buffer architecture and distributed decoupling capacitor in a chip. The proposed circuits are evaluated with i8052 MCU which is shown reducing of delta current 1/3 times and improvement of EMI more 10dBuV compared with conventional processors.

  • PDF

Design of Improved EMI Filter (개선된 EMI Filter 설계 및 제작)

  • 배대환;구동우;김동일;송재만
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.798-806
    • /
    • 2001
  • As electronic industry and radio communication technologies progress, the electrical and electronic equipments are lightened, minimized, and operated by low power. At the same time, these equipments react sensitively by electromagnetic wave noise. It is a origine these equipments to wrong-operation. In this paper, we focused on the design and preperation condition of a advanced EMI filter. This filter sowed superior attenuation effect of 10 dB~20 dB compare with typical filter in the range of frequency from 150 kHz to 30 GHz and superior character over the variation of a load.

  • PDF

EMC Design and Evaluation in Conduction Environment (전도성 EMC 설계 및 검증기술)

  • Kim, Tae-Yun;Im, Seong-Bin;Choe, Seok-Won
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • This paper describes the analysis method to define the system specification for conducted EMI environment and verification method to evaluate the conducted EMI performance. Conducted EMI environment is characterized by the electrical power subsystem which is mainly issued by the switching circuit noise, common ground impedance coupling. To define and control these EMI problems, EMI assesment through system analysis are preceded at the early design phase and then EMI reduction methods are applied during the unit/system development phase. System EMC should be carefully controlled and designed in the consideration of EMC safety margin and its performance is fully evaluated at the whole development period.

  • PDF

PI(Power Integrity)를 이용한 EMI 개선

  • Lee, Suk-Yeun;Chung, Ki-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1195-1196
    • /
    • 2008
  • It is difficult to solve PCB(Printed Circuit Board) Noise problem. Because Electronic circuit system operates very high frequency. Resonance analysis of PCB layout by PI(Power Integrity) Simulation method visualizes distribution of Switching noise between VDD and GND. By using de-cap, we reduce impedance and solve the EMI problems.

  • PDF

Design of EMI Reduction of SMPS Using MLCC Filters (MLCC를 이용한 SMPS의 EMI 저감 설계)

  • Choi, Byeong-In;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.97-105
    • /
    • 2020
  • Recently, as the data speed and operating frequencies of Ethernet keeps increasing, electro magnetic interference (EMI) also becomes increasing. The generation of such EMI will cause malfunction of near electronic devices. In this study, EMI filters were applied to reduce the EMI generated by DC-DC SMPS (switching mode power supply), which is the main cause of EMI generation of Ethernet switch. As the EMI filter, MLCCs with excellent withstanding voltage characteristics were used, which had advantages in miniaturization and mass production. Two types of EMI MLCC filters were used, which are X-capacitor and X, Y-capacitor. X-capacitor was composed of 2 MLCCs with 10 nF and 100 nF capacity and 1 Mylar capacitor. Y-capacitor was consisted of 6 MLCCs with a capacity of 27 nF. When only X-capacitor was applied as EMI filter, the conductive EMI field strength exceeded the allowable limit in frequency range of 150 kHz ~ 30 MHz. The radiative EMI also showed high EMI strength and very small allowable margin at the specific frequencies. When the X and Y-capacitors were applied, the conductive EMI was greatly reduced, and the radiation EMI was also found to have sufficient margin. In addition, X, Y-capacitors showed very high insulation resistance and withstanding resistance performances. In conclusion, EMI X, Y-capacitors using MLCCs reduced the EMI noise effectively and showed excellent electrical reliability.

Performances of Digital Amplitude-Frequency Modulation System (디지틀 진폭-주파수 변조 시스템의 특성)

  • 홍현성;남호법;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.9 no.4
    • /
    • pp.157-162
    • /
    • 1984
  • The data transmission in radio channel is mainly influenced by interfere and random noise. The increasing man-made impulsive noise environment has the necessity to consider impulsive noise than conventional white gaussian noise in digital communications. In this paper, we have investigated the error rate performance of hybrid modulation system. AFSK, which is composed of ASK and FSK in the environment of electromaganetic interference (EMI), especially impulsive noise.

  • PDF

A Study on the Reduction of Conducted Noise Emission from an Interior LED Lighting Module with TRIAC Dimming Control (TRIAC 디밍제어방식을 적용한 실내 LED 조명기기의 전도성 잡음 저감에 관한 연구)

  • Seo, Jung-Nam;Yu, Yong-Su;Yeo, In-Seon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.109-113
    • /
    • 2011
  • This paper analyzes the noise sources of an LED lighting module with TRIAC dimming control and proposes an improved EMI filter design for the reduction of conducted noise emission. TRIAC dimming invokes problems of input oscillation and capacitor overvoltage at the lighting module. The proposed double LC filter reduces high noise level from the circuit. The experimental and simulation results show that this approach can make significant contributions to the reduction of conducted noise emission from an LED lighting module with TRIAC dimming control.

Design of Wideband Facility Power-line EMI filter (광대역 설비용 전원선 EMI 필터의 설계)

  • Chung, Se-Kyo;Lim, Jeong-Gyu;Kim, Mu-Hyun;Kang, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.440-448
    • /
    • 2009
  • Facility power-line electromagnetic interference (EMI) filters are used to provide radio frequency(RF) isolation between dedicated power distribution services and noise sensitive local power distribution systems. This type of EMI filters generally needs a high current capacity and, in some special applications, a high insertion loss of a minimum 100dB from 14kHz through 10GHz per MIL-STD 220 is required. This paper deals with an analysis and design of a wideband facility power-line EMI filter with the above requirements. The characteristics of the inductor and capacitor at high frequencies are investigated. The characteristics and design method of the facility EMI filter with a high order LC network are also presented. The prototype filter is finally implemented and its performance is verified from the experimental results.