• 제목/요약/키워드: EMG Signals

Search Result 335, Processing Time 0.023 seconds

Wireless Power Transmission Technology for Implantable Telemetry Device based on Multiple Transmit Coils (다중코일방식에 기초한 원격 생체 정보 측정을 위한 무선전력전송 기술)

  • Ryu, Young-Kee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.203-211
    • /
    • 2015
  • The implanted telemetry system provides the monitoring of species while they move within their cages. Species monitored include mice, rats, rabbits, dogs, pigs, primates, sheep, horses, cattle, and others. A miniature transmitter implanted in each animal measures one or more parameters. Parameters measured include arterial pressure, intra-pleural pressure, left ventricular pressure, intra-ocular pressure, bladder pressure, ECG, EMG, EEG, EOG, temperature, activity, and other parameters and transmits the data via radio frequency signals to a nearby receiver. Every conventional dedicated transmitter contains one or more sensors, cpu and battery. Due to the expected life of battery, the measuring time is limited. To overcome these problems, electromagnetic inductive coupling based wireless power transmission technology using multiple transmit coils were proposed. Each coil having different active area are driven by the coil driver. In this research, parallel resonance based coil driver was proposed. In addition, the device to detect where the receiver is positioned was proposed. From the experiments we show how to determine the driving condition of coil driver.

Effects of Ramp Slope and Height on Usability and Physiology during Wheelchair Driving (경사로의 기울기와 높이에 따른 휠체어 사용자의 사용성 및 생리적 특성 분석)

  • Kim, Chung-Sik;Lee, Dong-Hun;Lee, Jee-Hea;Kwon, Sung-Hyuk;Chung, Min-K.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.681-686
    • /
    • 2010
  • Although the height of a ramp is an important design element, it has not been considered in prior studies. Therefore, in this study, the ramp slope and height are considered as independent variables. To analyze the effects of the slope and height, five levels of slope (1:6, 1:8, 1:10, 1:12 and 1:14) and three levels of height (15cm, 30cm and 45cm) are considered. For the dependent variables, the total time, velocity and perceived discomfort were considered as usability measures, pulse rate changes and EMG signals of four related muscles (extensor carpi radialis, triceps brachii, anterior deltoid and posterior deltoid) were considered as physiology measures. As a result, differences among usability and physiological characteristic for the five slopes increased as the height increased. Additionally, slope effects were minor when the height was low (15cm). Almost domestic/international regulations and guidelines related to ramp recommended 1:12 slope for the ramp design, however, there was no significant difference between 1:10 and 1:12 according to result of this study. In addition, slope effects were minor at a low height; thus, a slope of 1:8 can be recommended if the installation space for a gentler ramp is not sufficient.

The Effect of Graded Exercise-Induced Fatigue on Position Sense of the Knee (근피로를 유발하는 운동강도 변화가 슬관절의 위치감각 인지에 미치는 영향)

  • Yi, Chung-Hwi;Choi, Jong-Duk;Lee, Kang-Noh;Lee, Dong-Ryul;Choi, Jae-Myung
    • Physical Therapy Korea
    • /
    • v.6 no.3
    • /
    • pp.22-37
    • /
    • 1999
  • It was recently reported that exercise-induced fatigue is related to joint position sense although some controversy remains. The purposes of this study were to examine the effect on the accuracy of reproducing the knee angles after a fatiguing isokinetic quadriceps exercise at four different levels (10%, 30%, 50%, and 70% of maximal force) and to find the optimal exercise level without causing knee joint proprioception impairment. Forty healthy women, ages 19 to 27, were randomly assigned to four experimental groups. Before and after the exercise, accuracy of positioning with respect to auditory feedback for specific angles was estimated by calculating the mean errors between specific angles and reproduction angles. Fatigue was measured by EMG signals displayed by a frequency spectrum analysis during the quadriceps exercise. Results showed that there was no significant difference in accuracy of the knee joint positioning sense following the exercises in group 1, group 2, and group 3 (10%, 30%, and 50% of maximal force, respectively); the exception being group 4 (70%). Fatigue level was significantly increased in group 4 but there were no significant increases of fatigue level in group 1, group 2, or group 3. The results concluded that the optimal exercise level to acquire the therapeutic exercise effectiveness without position sense impairment was at 50% of maximal force. Further studies using large sample size and patient groups with poor knee joint proprioception would be needed to confirm this conclusion and to clarify the possibility of clinical applications.

  • PDF

Development of the Pre-amplifier and the DSP Board for the Potable EEG Biofeedback System (포터블 뇌파 바이오피드백 시스템을 위한 전치증폭기 및 DSP 하드웨어의 설계)

  • Lee, Kyoung-Il;Ahn, Bo-Sep;Park, Jeong-Je;Lee, Seung-Ha;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.121-127
    • /
    • 2003
  • In this study, we carried out a study for implementation of the pre-amplifier and the digital signal processing part for the potable EEG biofeedback system. As we consider characteristics of the EEG signal, we designed the pre-amplifier to obtain the EEG signal to be reduced noise signal. Because the EEG signal include EOG, EMG, ECG signals etc, it is difficult to analyze of the EEG signal. Therefore, we developed DSP board and operation program which was embed the LMS adaptive filter algorithm and operate with the pre-amplifier in the real time. The simulation signal and pure EEG signal is used in the experiment. As the result, we confirmed good efficiency of developed system and possibility of application to the portable EEG biofeedback system.

Biomechanical Analysis of Trail Running Shoes Applied to Korean Shoe-Lasts (한국인 족형을 적용한 트레일 러닝화의 생체역학적 분석)

  • Park, Seung-Bum;Lee, Kyung-Deuk;Kim, Dae-Woong;Yoo, Jung-Hyeon;Kim, Kyung-Hun;An, Chang-Shin;Lee, Tae-Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.221-230
    • /
    • 2010
  • The purpose of this study was to analyze biomechanical factors of trail running shoes applied to korean shoe-lasts. 10 healthy male subjects with an average age of 37.2 years(SD=8.28), weight of 69.6 kg(SD=10.56) and a height of 171 cm(SD=4.93) were recruited for this study. Ten males walked on a treadmill wearing four different shoes. Foot pressure data was collected using a Pedar-X mobile system(Novel Gmbh., Germany) operating at the 1000 Hz. Surface EMG signals for tibialis anterior, gastrocnemius, vastus lateralis and biceps femoris were acquired at 1000 Hz using Noraxon TeleMyo DTS system(Noraxon Inc., USA). Foot pressure and leg muscle fatigue were measured and calculated during walking. The results are as follows: After walking 60 minutes, Type A showed a lower MPF. MPF values were significantly different from each muscle(p<.05). Therefore, Type A shoe might decrease muscle fatigue in the legs while walking. In addition, Type It showed that Type A shoe has the highest contact area and the lowest maximum pressure. As a result of the analysis, Trail running shoes will use a new design to reduce muscle fatigue and are expected to increase comfort and fitting.

Effect of Craniocervical Flexion on Muscle Activities of Abdominal and Cervical Muscles During Abdominal Curl-Up Exercise

  • Yoon, Tae-Lim;Kim, Ki-Song
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.32-39
    • /
    • 2013
  • Abdominal curl-up exercise may excessively increased superficial neck flexor such as sternocleidomastoid (SCM) muscle. Also, the muscle activity of the abdominal muscles haven't investigated during abdominal curl-up with craniocervical flexion (CCF). Therefore, the purpose of our study was to determine the effect of CCF on the muscle activity of the abdominal and SCM muscles during abdominal curl-up. Twelve healthy subjects (six men and six women) with no history of abdominal or lower back pain within 6 weeks were recruited. Surface electromyographic signals were collected on SCM, rectus abdominis (RA), internal oblique (IO), and external oblique (EO) muscles bilaterally during performing the traditional abdominal curl-up and the abdominal curl-up with CCF. Paired t-tests were used to compare the differences in the muscle activity of the bilateral SCM, RA, EO, and IO muscles between the traditional abdominal curl-up and the abdominal curl-up with CCF (p<.05). There was significantly lower electromyogram (EMG) activity of the both SCMs during the abdominal curl-up with CCF (Right SCM, $39.50{\pm}15.29%MVIC$; Left SCM, $38.24{\pm}17.31%MVIC$) than with the traditional abdominal curl-up (Right SCM, $54.85{\pm}20.05%MVIC$; Left SCM, $53.18{\pm}26.72%MVIC$) (p<.05). The activity of abdominal muscles were not significantly different between the traditional abdominal curl-up and the abdominal curl-up with CCF. The abdominal curl-up with CCF requires significantly less muscle activity of SCM. Consequently, the abdominal curl-up with CCF is recommended to prevent excessive activation of superficial cervical flexors during abdominal curl-up exercise.

The Effects of Sling Bridging Exercise to Pain Scale and Trunk Muscle Activity in Low Back Pain Patients

  • Jeong, Eun Dong;Chae, Chang Woo;Yun, Hong Kyu;Woo, Kwang Seog;Kim, Dong Hyun;Kim, Seung Min
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.4 no.1
    • /
    • pp.523-531
    • /
    • 2013
  • Most patients with chronic low back pain experience functional disability of trunk muscle, and limitations in physical activity. While there are many types of exercise programs available, in recent years sling exercise has been emerging as the exercise program for spinal stabilization. It has been supported by a great amount of research with positive findings on its effectiveness. This research studies the effects of bridging exercise, conducted on a sling, on pain level and trunk muscle activation in supine, sidelying, and prone positions during a 4 weeks period. 10 healthy people(normal group, n=10) and 28 patients with low back pain participated in this study. 28 patients were divided into two groups; one group participated in exercise with the sling(experimental group, n=14) and the other group exercised without the sling(control group, n=14). They were asked to use the Numerical Rating Scale(NRS) to answer to the level of their pain they felt (no pain: 0 point, severe pain: 10 points). During sling bridging exercises, the muscle activity level in each muscle measured in each position was standardized as three seconds of EMG signals during five seconds MVIC. In conclusion, the experimental group with four weeks of sling bridging exercise experienced a statistically significant reduction in the pain level(p<.05) and increase in the muscle activities of erector spinae when in supine position, internal oblique when in sidelying position, and rectus abdominis in prone position(p<.05). Regular sling bridging exercise reduces the low back pain and enhances other trunk muscle activation, thereby positively affect spinal stabilization.

Characteristics of EMG Median Frequency and Torque During Isometric Back Extension Exercises (등척성 요추 신전운동 시 중앙주파수와 토크의 특성)

  • Kang, S. J.;Park, S. J.;Jang, K.;Park, K. H.;Kwon, O. Y.;Kim, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • Localized muscle fatigue can be identified by a downward shift of the EMG frequency typically represented by a fall in the median frequency The Present experimental study was Performed to investigate the time change of the median frequency and the muscle torque during maximal isometric back extension exercises at different exercise angles (0$^{\circ}$, 12$^{\circ}$, 36$^{\circ}$and 72$^{\circ}$) Twenty heath subjects (mean age : 24.35 $\pm$ 2.70) were Participated in this study Median frequency was extracted from EMG signals by employing the fast Fourier transform. Initial median frequency and the slope of median frequency was not significantly correlated with the muscle torque. Pearson's Product moment correlation was used to quantify the relationship between slopes of median frequency and torque. The results may suggest that the exorcise angle during maximal isometric back extension exercises does not affect the slopes of the median frequency and torque, and y-intercept of the median frequency among exercise angles There was no significant correlation between slopes of median frequency and torque. But there was a moderate correlation between median frequency and torque at each exercise angle. In conclusion, the exercise angle during maximal isometric back extension exercise is not a direct effect on slopes of median frequency and torque. But results showed that the shift of median frequency and torque shift were highly correlated in all subjects.

Effects of Muscle Activation Pattern and Stability of the Lower Extremity's Joint on Falls in the Elderly Walking -Retrospective Approach- (노인 보행 시 하지 근 활동 양상과 관절의 안정성이 낙상에 미치는 영향 -후향성 연구-)

  • Ryu, Jiseon
    • 한국체육학회지인문사회과학편
    • /
    • v.57 no.3
    • /
    • pp.345-356
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the local stability of the lower extremity joints and muscle activation patterns of the lower extremity during walking between falling and non-falling group in the elderly women. Method: Forty women, heel strikers, were recruited for this study. Twenty subjects (age:72.55±5.42yrs; height:154.40±4.26cm; mass:57.40±6.21kg; preference walking speed:0.52±0.17m/s; fall frequency=1.70±1.26 times) had a history falls(fall group) within two years and Twenty subjects (71.90±2..90yrs; height:155.28±4.73cm; mass:56.70±5.241kg; preference walking speed: 0.56±0.13m/s) had no history falls(non-fall group). While they were walking on a instrumented treadmill at their preference speed for a long while, kinematic and EMG signals were obtained using 3-D motion capture and wireless EMG electrodes, respectively. Local stability of the ankle and knee joint were calculated using Lyapunov Exponent (LyE) and muscles activation and their co-contraction index were also quantified. Hypotheses were tested using one-way ANOVA and Mann-Whitey. Spearman rank was also used to determine the correlation coefficients between variables. Level of significance was set at p<.05. Results: Local stability in the knee joint adduction-abduction was significantly greater in fall group than non-fall group(p<.05). Activation of anterior tibials that acts on the foot segment dorsal flexion was greater in non-fall group than fall group(p<.05). CI between gastrocnemius and anterior tibials was found to be significantly different between two groups(p<.05). In addition, there was significant correlation between CI of the leg and LyE of the ankle joint flexion-extention in the fall group(p<.05). Conclusion: In conclusion, muscles that act on the knee joint abduction-adduction as well as gastrocnemius and anterior tibials that act on the ankle joint flexion-extention need to be strengthened to prevent from potential fall during walking.

Development of Self-trainer Fitness Wear Based on Silicone-MWCNT Sensor (실리콘-탄소나노튜브 센서 기반의 셀프트레이너 피트니스 웨어 개발)

  • Cho, Seong-Hun;Kim, Kyung-Mi;Cho, Ha-Kyung;Won, You-Seuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.493-503
    • /
    • 2018
  • Recently, as living standards have improved, many people are becoming more interested in health, and self-training is increasing through exercise to prevent and manage pre-illness. In general, an imbalance of muscles causes asymmetry of posture, which can cause various diseases by accompanying an adjustment force, circulation action, displacement of internal organs, etc.. In this study, the development of fitness software that can be self - training among smart wears has attracted considerable attention in recent years. In this study, a technology was proposed for the commercialization of self - trainer fitness wear by a simulation through Android - based applications. Self - trainer fitness software was developed by combining a conductive polymer, fashion design, sewing, and electric and electronic technology to monitor the unbalance of the muscles during exercise and make smart wear that can calibrate the asymmetry by oneself. In particular, a polymer sensor was fabricated by deriving the optimal MWCNT concentration, and the electrode signal was collected by attaching the electrode to the optimal position, where the electrode signal line using the conductive fiber was designed and attached to collect the signal. A signal module that converts the bio-signals collected through electrical signal conversion and transmits them using Bluetooth communication was designed and manufactured. Self-trainer fitness software that can be commercialized was developed by combining noise cancellation with Android-based self-training application using a software algorithm method.