• 제목/요약/키워드: EMG (electromyography)

검색결과 613건 처리시간 0.025초

정적 부하의 비대칭적 적용에 따른 등 근육의 근전도 분석 (An Electromyographic Analysis of Back muscle Activity when Subjects are Lifting Static Loads in One Hand)

  • 김태영;박은영;이응상
    • 한국전문물리치료학회지
    • /
    • 제4권1호
    • /
    • pp.78-86
    • /
    • 1997
  • Back muscles play an important role in protecting the spine. Epidemiological studies have shown that loads imposed on the human spine during daily living play a significant role in the onset of low back pain. No previous study has attempted to correlate the response of the trunk musculature with the type of external load. The purpose of this study was to use surface electromyography (EMG) to quantify the relative demands placed on the back muscles while lifting loads in one hand. Forty asymptomatic, twenty year-old subjects stood while lifting loads of 10% of body weight(BW) unilaterally. All EMG data were normalized to a percentage of the EMG voltage produced during no-load standing(%EMG). Our major analysis involved a paired t-test for repeated measures. Of particular note was the fact that the ipsilateral 10% of BW condition produced statistically less % EMG change than did the contralateral 10% of the condition.

  • PDF

근피로도 측정을 위한 중간 주파수와 Spike 파라미터의 신뢰도 비교 및 향상된 Spike 검출 알고리듬에 관한 연구 (A Study on the Reliability Comparison of Median Frequency and Spike Parameter and the Improved Spike Detection Algorithm for the Muscle Fatigue Measurement)

  • 이성주;홍기룡;이태우;이상훈;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.380-388
    • /
    • 2004
  • This study proposed an improved spike detection algorithm which automatically detects suitable spike threshold on the amplitude of surface electromyography(SEMG) signal during isometric contraction. The EMG data from the low back muscles was obtained in six channels and the proposed signal processing algorithm is compared with the median frequency and Gabriel's spike parameter. As a result, the reliability of spike parameter was inferior to the median frequency. This fact indicates that a spike parameter is inadequate for analysis of multi-channel EMG signal. Because of uncertainty of fixed spike threshold, the improved spike detection algorithm was proposed. It automatically detects suitable spike threshold depending on the amplitude of the EMG signal, and the proposed algorithm was able to detect optimal threshold based on mCFAR(modified Constant False Alarm Rate) in the every EMG channel. In conclusion, from the reliability points of view, neither median frequency nor existing spike detection algorithm was superior to the proposed method.

Effect of repetitive wrist extension with electromyography-triggered stimulation after stroke: a preliminary randomized controlled study

  • Lee, Yoseb;Cha, Yuri;Kim, Young;Hwang, Sujin;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권3호
    • /
    • pp.127-133
    • /
    • 2017
  • Objective: The purpose of this study was to explore the effect of repetitive wrist extension task training with electromyography (EMG)-triggered neuromuscular electrical stimulation (NMES) for wrist extensor muscle recovery in patients with stroke. Design: Randomized controlled trial. Methods: Fifteen subjects who had suffered a stroke were randomly assigned to an EMG-triggered NMES group (n=8) or control group (n=7); subjects in both groups received conventional therapy as usual. Subjects in the experimental group received application of EMG-triggered NMES to the wrist extensor muscles for 20 minutes, twice per day, five days per week, for a period of four weeks, and were given a task to make a touch alarm go off by activity involving extension of their wrist. In the control group, subjects performed wrist self-exercises for the same duration and frequency as those in the experimental group. Outcome measures included muscle reaction time and spectrum analysis. Assessments were performed during the pre- and post-treatment periods. Results: In the EMG-triggered NMES group, faster muscle reaction time was observed, and median frequency also showed improvement, from 68.2 to 75.3 Hz, after training (p<0.05). Muscle reaction time was significantly faster, and median frequency was significantly higher in the experimental group than in the experimental group after training. Conclusions: EMG-triggered NMES is beneficial for patients with hemiparetic stroke in recovery of upper extremity function.

A Study of the Electrical Properties of the Buccal Area using Facial Surface Electromyography

  • Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • 제34권2호
    • /
    • pp.75-82
    • /
    • 2017
  • Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.

Reproducibility of Electromyography Signal Amplitude during Repetitive Dynamic Contraction

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • 대한인간공학회지
    • /
    • 제30권6호
    • /
    • pp.689-694
    • /
    • 2011
  • Objective: The aim of this study is to evaluate the fluctuation of signal amplitude during repetitive dynamic contraction based on surface electromyography(EMG). Background: The most previous studies were considered isometric muscle contraction and they were difference to smoothing window length by moving average filter. In practical, the human movement is dynamic state. Dynamic EMG signal which indicated as the nonstationary pattern should be analyzed differently compared with the static EMG signal. Method: Ten male subjects participated in this experiment, and EMG signal was recorded by biceps brachii, anterior/posterior deltoid, and upper/lower trapezius muscles. The subject was performed to repetitive right horizontal lifting task during ten cycles. This study was considered three independent variables(muscle, amplitude processing technique, and smoothing window length) as the within-subject experimental design. This study was estimated muscular activation by means of the linear envelope technique(LE). The dependent variable was set coefficient of variation(CV) of LE for each cycle. Results: The ANOVA results showed that the main and interaction effects between the amplitude processing technique and smoothing window length were significant difference. The CV value of peak LE was higher than mean LE. According to increase the smoothing window length, this study shows that the CV trend of peak LE was decreased. However, the CV of mean LE was analyzed constant fluctuation trend regardless of the smoothing window length. Conclusion: Based on these results, we expected that using the mean LE and 300ms window length increased reproducibility and signal noise ratio during repetitive dynamic muscle contraction. Application: These results can be used to provide fundamental information for repetitive dynamic EMG signal processing.

LSTM을 이용한 표면 근전도 분석을 통한 서로 다른 손가락 움직임 분류 정확도 향상 (Improvement of Classification Accuracy of Different Finger Movements Using Surface Electromyography Based on Long Short-Term Memory)

  • 신재영;김성욱;이윤성;이형탁;황한정
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권6호
    • /
    • pp.242-249
    • /
    • 2019
  • Forearm electromyography (EMG) generated by wrist movements has been widely used to develop an electrical prosthetic hand, but EMG generated by finger movements has been rarely used even though 20% of amputees lose fingers. The goal of this study is to improve the classification performance of different finger movements using a deep learning algorithm, and thereby contributing to the development of a high-performance finger-based prosthetic hand. Ten participants took part in this study, and they performed seven different finger movements forty times each (thumb, index, middle, ring, little, fist and rest) during which EMG was measured from the back of the right hand using four bipolar electrodes. We extracted mean absolute value (MAV), root mean square (RMS), and mean (MEAN) from the measured EMGs for each trial as features, and a 5x5-fold cross-validation was performed to estimate the classification performance of seven different finger movements. A long short-term memory (LSTM) model was used as a classifier, and linear discriminant analysis (LDA) that is a widely used classifier in previous studies was also used for comparison. The best performance of the LSTM model (sensitivity: 91.46 ± 6.72%; specificity: 91.27 ± 4.18%; accuracy: 91.26 ± 4.09%) significantly outperformed that of LDA (sensitivity: 84.55 ± 9.61%; specificity: 84.02 ± 6.00%; accuracy: 84.00 ± 5.87%). Our result demonstrates the feasibility of a deep learning algorithm (LSTM) to improve the performance of classifying different finger movements using EMG.

근활성도(EMG) 측정 전극 레이어 설계에 따른 성능 및 안정성 평가 (Performance and Stability Evaluation of Muscle Activation (EMG) Measurement Electrodes According to Layer Design)

  • 구본학;이동희;김주용
    • 감성과학
    • /
    • 제26권4호
    • /
    • pp.41-50
    • /
    • 2023
  • 본 연구는 EMG(electromyography) 텍스타일 전극 개발을 목적으로 레이어 수의 디자인 및 원단을 다르게 하여 성능 및 신호 획득 안정성을 평가한다. 레이징 및 프레스 공정을 통하여 텍스타일 전극을 제조하며 Layer-0, Layer-1, Layer-2로 레이어 유무 및 수에 따른 결과를 분석했다. 이에 레이어 유무에 따라서는 근활성 측정에 영향을, 수가 많을수록 높은 성능이 나타남을 확인할 수 있었다. Layer-2 구조로 통일하여 5가지의 원단(네오프렌, 스판덱스 쿠션, 폴리에스테르 100%, 나일론 스판덱스, 광목 캔버스)으로 전극을 제조해 실험해 보았다. 성능적인 면에서, 원단의 중량이 높은 나일론 스판덱스가 높은 성능을 보였으며, 스판쿠션 텍스타일 전극이 근활성도 수득에 높은 안정성을 보였다. 이에 위 연구는 레이어에 따른 성능 연관성과 전극-피부사이의 닿는 면적 간의 관계 등을 고찰하여 슬리브 전체의 의복압을 늘리는 대신 특정 센서 측정 부위에만 높은 압력을 가함으로 차후 연구에서 레이어의 수 및 물성에 따른 전극의 공학적 설계 가능성을 제시한 의의가 있다.

공간필터에 의한 운동단위 활동전위의 분해능 향상에 관한 연구 (A Study on Improvement of MUAP Resolution using Spatial Filter)

  • 양덕진;전창익;이영석;이진;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권1호
    • /
    • pp.55-64
    • /
    • 2004
  • Conventional bipolar surface electromyography(EMG) technique detects only the superimposed electromyographic activity of a large number of motor units due to its low spatial resolution. For the diagnosis of neuromuscular disorder, the information of single MU is required. In this paper, 9 channel array surface electrode system was as designed and MLoG filter was proposed. Also the MCPT(modified convolution processing technique)method was proposed for the improvement of MUAP resolution. For performance evaluation, power spectrum analysis of random data and raw EMG signal comparison of MUAP shape and quantitative estimation of SNR were executed. As a result, the MUAP resolution improvement of 32% was obtained from the standpoint of the signal-to-noise ratio(SNR).

건강한 여성에 대한 근전도를 이용한 생체되먹이기 훈련이 안쪽빗넓은근과 가쪽넓은근의 근활성비와 개시시간에 미치는 영향 (The Effect of Electromyographic Biofeedback Training on the VMO/VL Electromyographic Activity Ratio and Onset Timing in Women without Knee Pathology)

  • 김현희;송창호
    • 대한물리의학회지
    • /
    • 제5권4호
    • /
    • pp.605-613
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the VMO/VL ratio and onset timing using EMG biofeedback training over a 5-day period. Methods : Twenty-one healthy female college students with no known right knee musculoskeletal dysfunction were recruited this study. Muscle activity was measured by surface electromyography(Myosystem 1400A, Noraxon Inc., U.S.A). Statistical analysis was used two-way repeated ANOVA to know difference between the vastus lateralis and vastus medialis oblique onset timing differences, VMO/VL ratio. Results : Biofeedback training group significantly improved VMO/VL ratio and EMG activity of the vastus medialis oblique after intervention. Conclusion : These result indicate that biofeedback training on the vastus medialis oblique has effect on the VMO/VL ratio. EMG biofeedback can be recommended for the facilitation of VMO muscular recruitment.

Actuation of Artificial Muscle Based on IPMC by Electromyography (EMG) Signal

  • Lee, Myoung-Joon;Jung, Sung-Hee;Moon, In-Hyuk;Lee, Suk-Min;Mun, Mu-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1173-1178
    • /
    • 2005
  • This paper proposes an IPMC actuating system with a bio-mimetic function. EMG signals generated by an intended contraction of muscles in forearm are used for the actuation of the IPMC. To obtain higher actuation force of the IPMC, the single layered as thick as 800 [${\mu}$m] or multi-layered IPMC (Nafion) of which each layer can be as thick as 178 [${\mu}$m] are prepared. The experimental results using an implemented IPMC control system show a possibility and a usability of the bio-mimetic artificial muscle.

  • PDF