• Title/Summary/Keyword: EMC test

Search Result 130, Processing Time 0.023 seconds

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

A Study on the Evaluation Method of Field Uniformity(FU) for Radiated Immunity Test of Vehicle Component (차량용 전장품의 복사내성 평가를 위한 균일장 측정방법에 대한 연구)

  • Yoon, Jae Sang;Hong, Hyun Gwi;Kam, Dong Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.633-636
    • /
    • 2017
  • This thesis is about the evaluation method of field uniformity for radiated immunity test of vehicle component. Radiated immunity test is to find out whether a EUT has enough immunity or hold normal operation during applied electromagnetic interference. Field Uniformity(FU) measurement is essential for generate uniform field on DUT and Harness. But Standard of Radiated Immunity(RI) test for vehicle component based on ISO 11452-2 has not been specified a Field Uniformity(FU). So compared and analyzed with other standard which is defined by a specified a Field Uniformity. As a result, deviation occurs in the difference test condition and test method. In this thesis, proposal new measurement method of field uniformity that is considered test conditions of ISO 11452-2 and check the validity through actual test.

  • PDF

A Design of Half-wave length Resonant Dipole Antennas and Variations of Antenna Factors by the Antenna Dimensions (반파장 공진다이폴 안테나의 설계와 안테나 치수가 안테나 인자에 미치는 영향)

  • 김기채;정낙삼
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.8
    • /
    • pp.785-792
    • /
    • 1991
  • We designed the hal wavelength dipole antennal which can be used for he determination of the suitability of an antenna test site and considered the characteristic of antenna factors by using the moment methods. Antennal factors remain almost constant with negligible variations for the variations of $\pm$1 mm antenna dimention-radius and length. comparisons are mae between measured values and calculated results for the input impedance.

  • PDF

Characteristics of Capacitive Coupler for Partial Discharge Measurement in 6.6kV Rotating Machines (6.6kV 회전기 부분방전 측정용 Capacitive Coupler 특성)

  • Kang, Dong-Sik;Yoon, Dae-Hee;Kim, Yong-Joo;Yun, Yung-Ho;Lee, Jung-Jun;Song, Sang-Ock
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1619-1622
    • /
    • 2001
  • Recently many researches on the diagnosis of stator winding insulation for large rotating machines have been developed sine the 1970s. Capacitive coupler has been the most widely used sensor for on-line partial discharge(PD) in rotating machines. The 105 [pF] ceramic coupler(CC) has been developed to continuously measure the PD activity in operating motor stator windings. This paper presents frequency characteristics and laboratory test to compare traditional 80 [pF] epoxy-mica coupler(EMC) and 105 [pF] CC for PD measurement in 6.6 [kV] stator windings.

  • PDF

Changes in Surface EMG Parameters during Dynamic Wheelchair Propulsion (휠췌어 추진시 근전도 신호의 특성 변화)

  • Choi, Hwa - Soon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.777-789
    • /
    • 2001
  • The purpose of this study was to investigate the possibility of using surface electromyographic signals as a measure of muscle fatigue during the wheelchair propulsion. Subjects performed wheelchair exercise tests on a motor-driven treadmill with a constant-velocity of 1.25 m/sec. During each test, the raw EMC signals were acquired from the surface electrodes attached on the belly of five muscle groups: biceps brachii, pectoralis major. deltoid, triceps brachii, and trapezius. The median power frequency(MPF), and the root mean square(RMS) amplitude were calculated for each cyclic contraction in order to quantify muscle fatigue. During the wheelchair propulsion, the MPF decreased and the RMS increased in the trapezius and deltoid. However, the decreasing MPF and the increasing RMS also fluctuated severly during dynamic muscle contractions. Therefore, the MPF and RMS values should be estimated with well-designed methods and used with caution to quantify muscle fatigue during wheelchair propulsion.

  • PDF

Measurements and Analysis of Electromagnetic Shielding Effectiveness of PDP TV Screen Filters (PDP TV Screen Filter의 Shielding Effectiveness 측정 및 분석)

  • Park, Gyu-Bok;Kim, Yoon-Jung;Kim, Young-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.47-53
    • /
    • 2003
  • Screen filter of PDP TV plays an important role in satisfying the EMI/EMC specifications. Two types of filters, the mesh type and the sputter type, are used in PDP TVs, and this paper presents measurement results of the shielding effectiveness (SE) in the frequency range from 50MHz to 1GHz. Two methods were used for the measurement, one using network analyzer (NA) in an open area test site(OATS), and the other using the screen room. The overall conclusion is that the shielding effectiveness of the screen filter is related to the surface resistance of the screen filter. The mesh type screen filters are superior to the sputter types in the shielding effectiveness, which is varying with the frequency.

  • PDF

Broad-Band Design of Ferrite One-body EM Wave Absorbers for an Anechoic Chamber

  • Kim, Dong-Il;Son, June-Young;Park, Woo-Keun;Park, Dong-Han
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 2004
  • With the progress of the electronics industry and radio communication technology, certain problems, such as electromagnetic interference(EMI), have arisen due to the increased use of electromagnetic(EM) waves. International organizations such as CISPR, FCC, and ANSI have provided the standards for the EM wave environment and for the countermeasure of the electromagnetic compatibility(EMC). EM wave absorbers are used for constructing an anechoic chamber to test and measure EMI and electromagnetic susceptibility(EMS). In this paper, we have designed an one-body EM(electromagnetic) wave ferrite absorber, based on the equivalent material constants method for both normally and obliquely incident waves, whose absorption abilities are superior to that of the conventional ones. The fabricated absorber has a thickness of 27.68 mm and shows an absorption ability over 20 ㏈ in the frequency from 30 MHz to 6 ㎓.

A Study on the Reliability of Plastic BGA Package (플라스틱 BGA 패키지의 신뢰성에 관한 연구)

  • Kim, Gyeong Seop;Sin, Yeong Ui
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.222-222
    • /
    • 2000
  • PBGA(Plastic Ball Grid Array) is composed of some materials such as PCB(Printed Circuit Board), epoxy molding compound, die attach and so on. Reliability of PBGA package is weak compared with plastic packages. The weak points of reliability are the lower resistance to popcorn cracking, which is induced by moisture absorption in PCB, and the pressure cooker test corrosion, which is the basic problem due to the material characteristics of PCB. Introducing the PCB baking and the plasma treatment cleared the popcorn cracking phenomenon. The PCB baking and plasma treatment reduced the epoxy void by eliminating the source of moisture vaporization during the epoxy curing and enhanced the adhesion between PCB and epoxy. Also, plasma treatment enhanced the wettability of epoxy on PCB. The problem of corrosion is cleared using multi-functional epoxy. This type of EMC(Epoxy Molding Compound) is recommended in package using PCB as a substrate. (Received November 19, 1999)

A Study on the Reliability of Plastic BGA Package (플라스틱 BGA 패키지의 신뢰성에 관한 연구)

  • 김경섭;신영의
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.95-99
    • /
    • 2000
  • PBGA(Plastic Ball Grid Array) is composed of some materials such as PCB(Printed Circuit Board), epoxy molding compound, die attach and so on. Reliability of PBGA package is weak compared with plastic packages. The weak points of reliability are the lower resistance to popcorn cracking, which is induced by moisture absorption in PCB, and the pressure cooker test corrosion, which is the basic problem due to the material characteristics of PCB. Introducing the PCB banking and the plasma treatment cleared the popcorn cracking phenomenon. The PCB banking and plasma treatment reduced the epoxy void by eliminating the source of moisture vaporization during the epoxy curing and enhanced the adhesion between PCB and epoxy. Also, plasma treatment enhanced the wettability of epoxy on PCB. The problem of corrosion is cleared using multi-functional epoxy. This type of EMC(Epoxy Molding Compound) is recommended in package using PCB as a substrate.

  • PDF

다목적실용위성 2호의 각 유닛과 Harness 간의 EMC 해석

  • 이나영;이진호
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.106-106
    • /
    • 2003
  • 인공위성의 전기적 호환성 해석은 인공위성의 각 유닛들에서 발생할 수 있는 잡음이 인공위성의 정상 동작에 미치는 영향을 분석하고 그 영향을 최소로 만들 수 있는 방안을 연구하기 위해 필요하다. 본 논문에서는 인공위성의 탑제컴퓨터와 탑제체 간의 인터페이스에서 전기 신호의 호환성 해석, Harness의 호환성 해석 그리고 radiation 해석이 이루어졌다. 인공위성의 탑제컴퓨터와 탑제체 간의 인터페이스에서 전기 신호의 호환성 해석은 전기 신호의 전압 레벨이 전압 히스테리시스의 경계 영역에서 충분한 여유를 가지고 있는지 판단하기 위해 필요하다. 전기 신호에 충분한 여유분이 없는 경우 여유분을 증가시키기 위한 방법이 제안되었으며 제안된 방법에 의해 인터페이스의 올바른 동작에 충분한 여유분이 생겼음이 시뮬레이션 결과에 나타났다. Harness의 호환성 해석은 다목적실용위성 2호에 사용된 Harness에 대한 conductive epoxy potting의 전도도를 검증하기 위해 이루어졌다. 본 논문에서는 전송 임피던스 측정 방법을 이용하여 epoxy potting의 전도성이 모든 주파수 영역에서 인공위성의 요구사항에 만족함을 보여준다. Radiation 해석은 인공위성 시스템의 radiated emission(RE)을 추정하고 S-band 수신기와 GPS 안테나와 같은 수신단에 대한 상호간섭에 의한 위험도를 분석하기 위해 필요하다. RF 수신기의 수신 대역에서 발생한 잡음의 영향으로 신호대잡음비가 허용수치이하로 감소하여 위성 명령을 수신하는 동작에 지장을 초래할 수 있다. 본 논문에서는 RF 수신단에 가장 큰 영향을 미칠 것으로 예상되는 star tracker의 RE test 결과를 분석하여 test 결과가 GPS 수신기와 S-band 수신기의 각각의 성능에 적합한지 해석하였다. 또한 solar array regulator의 스윗칭에 의해 발생되는 radiation이 위성 구조체에 미치는 영향을 해석하고 시뮬레이션 하였다.

  • PDF