• 제목/요약/키워드: EMAT ultrasonics

검색결과 6건 처리시간 0.019초

비접촉 Lamb-EMAT를 이용한 두께감육 평가에 관한 연구 (Non-contact Ultrasonic Technique for the Thin Defect Evaluation by the Lamb-EMAT)

  • 김태형;박익근;이철구;김용권;김현묵;조용상
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.194-196
    • /
    • 2005
  • Ultrasonic guided waves are gaining increasing attention for the inspection of platelike and rodlike structures. At the same time, inspection methods that do not require contact with the test piece are being developed for advanced applications. This paper capitalizes on recent advances in the areas of guided wave ultrasonics and noncontact ultrasonics to demonstrate a superior method for the nondestructive detection of thinning defects simulating hidden corrosion in thin aluminum plates. The proposed approach uses EMAT(electro-magnetic acoustic transducer) for the noncontact generation and detection of guided plate waves. Interesting features in the dispersive behavior of selected guided modes are used for the detection of plate thinning. It is shown that mode cutoff measurements provide a qualitative detection of thinning defects. Measurement of the mode group velocity can be also used to quantify of thinning depth.

  • PDF

박판의 두께감육 평가를 위한 비접촉 유도초음파 검사 기법 (Non-contact Ultrasonic Technique for the Evaluation Wall Thinning of the Plate)

  • 박익근;김현묵;김태형;김용권;조용상;송원준
    • 비파괴검사학회지
    • /
    • 제25권4호
    • /
    • pp.287-293
    • /
    • 2005
  • 유도초음파는 박판이나 봉재와 같은 구조를 효율적으로 검사할 수 있는 초음파로 주목받고 있으며, 더불어 시험체를 비접촉으로 검사할 수 있는 기법이 개발되면서 다양한 분야에 응용하기 위해 연구되고 있다. 본 연구에서는 비접촉식 초음파기법과 유도초음파의 장점을 결합하여 기존의 검사기법에 비해 효율적인 검사기법을 제안하고자 하였으며, 실험적인 검증을 위해 알루미늄 박판에 모의 부식결함을 가공하여 두께감육을 검출하고 평가하였다. 제안된 비접촉식 초음파기법으로는 EMAT을 이용하여 유도초음파를 발생 및 수신하였다. 선택된 유도초음파 모드의 분산거동특성에서 모드 컷-오프는 두께 감육을 검출할 수 있는 정성적인 파라미터이며, 군속도 변화는 두께 감육의 깊이를 정량적으로 평가할 수 있는 파라미터로 나타났다.

전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구 (A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;김지훈;이창노;;양인영
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

전자기 초음파를 이용한 CF/Epoxy 복합적층판의 적층결함 특성평가 (On Characterization for Stacking Fault Evaluation of CF/Epoxy Composite Laminates Using an EMAT Ultrasonics)

  • 임광희;나승우;;이창노;박제웅;심재기;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 추계학술발표대회 논문집
    • /
    • pp.254-257
    • /
    • 2004
  • An electromagnetic acoustic transducers (EMAT) can usually generate or detect an ultrasonic wave into specimens across a small gap. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences there properties. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. It was shown experimentally that this shear waves for detecting the presence of the errors is very sensitive. It is found that high probability shows between tests and the model developed in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform(2-D FFT).

  • PDF

비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구 (Research on the Non-Contact Detection of Internal Defects in a Rail using Ultrasonic Waves)

  • 한순우;조승현;김준우;허태훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.617-625
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be a cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.

  • PDF

비접촉 초음파 방식의 철도레일 내부결함 검출에 관한 연구 (Research on the Non-Contact Detection of Internal Defects in a Rail Using Ultrasonic Waves)

  • 한순우;조승현;김준우;허태훈
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.1010-1019
    • /
    • 2012
  • Non-contact detection of internal defects in a rail using ultrasonic waves is discussed in this paper. Cracks in a rail may be the cause of a serious railway accident such as derailment if left undetected. Concurrent rail inspection method based on ultrasonic testing using piezoelectric transducers has several limitations as it should keep physical contact with the rail. This work suggests a non-contact detection of internal defects in a rail using ElectroMagnetic Acoustic Transducers (EMAT) which can produce and measure ultrasonic waves in a rail without any couplant. The EMATs for rail inspection are designed and fabricated and their working performance is verified through a series of experiments on various types of internal defects in test rails. The effect of lift-off between the transducers and the rail on the generated signals is also discussed.