• 제목/요약/키워드: EM scattering

검색결과 34건 처리시간 0.017초

Photocatalytic Cell Disruption of Giardia lamblia in a $UV/TiO_2$ Immobilized Optical-Fiber Reactor

  • 유미진;김병우
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1105-1113
    • /
    • 2004
  • Disinfection of a waterborne pathogenic protozoa, Giardia lamblia, by the conventional chlorine method has been known to be difficult. An alternative disinfection has been carried out by using a UV -light illuminating optical­fiber photoreactor. Light intensity diffused from one piece of a clad-removed optical-fiber was $1- 1.5{\mu}Em^{-2}s^{-1}$. Disinfection capability in a UV -light irradiated optical-fiber reactor suspended with 0.01 g $TiO_{2}\;dm^{-3}$ was 1.4 times that in the same reactor without $TiO_{2}$ photocatalysts. To resolve the absorption and scattering of UV light by the particles themselves as well as the difficulty of recycling particles in the slurry­type reactor, $TiO_{2}$ which was obtained by a hydrothermal method, was immobilized on clad-removed optical fibers. Such pretreatment of fiber surface resulted in an excellent transparency, which enhanced the UV light to diffuse laterally from a fiber surface. Coating time of the prepared solution by the hydrothermal method was not effective after more than two times. Disinfection capability in the $TiO_{2}$-immobilized optical-fiber reactor was $83\%$ in 1 h at $40^{\circ}C$, which was slightly higher than $76\%$ at $22^{\circ}C$ and $68\%$ at $10^{\circ}C$. Disinfection capability at $22^{\circ}C$ increased from $74\%$ at an initial pH of 3.4, through $76\%$ at pH 6.5, to $87\%$ at an initial pH of 10. Oxygen supply with air-flow rate of 5 $cm^3\;min^{-1}$ did not seem to increase the disinfection capability with UV /immobilized $TiO_2$.

나노결정 Fe73Si16B7Nb3Cu1 연자성분말과 숯분말 혼합 복합성형체의 전자파흡수 특성 (Electromagnetic Wave Absorption Properties of Fe73Si16B7Nb3Cu1-Based Nanocrystalline Soft Magnetic Powder Composite Mixed with Charcoal Powder)

  • 김선이;김미래;손근용;박원욱
    • 한국분말재료학회지
    • /
    • 제16권4호
    • /
    • pp.291-295
    • /
    • 2009
  • The electromagnetic wave absorption sheets were fabricated by mixing of $Fe_{73}Si_{16}B_7Nb_3Cu_1$ nanocrystalline soft magnetic powder, charcoal powder and polymer based binder. The complex permittivity, complex permeability, and scattering parameter have been measured using a network analyzer in the frequency range of 10 MHz$\sim$10 GHz. The results showed that complex permittivity of sheets was largely dependent on the frequency and the amount of charcoal powder : The permittivity was improved up to 100 MHz, however the value was decreased above 1 GHz. The power loss of electromagnetic wave absorption data showed almost the same tendency as the results of complex permittivity. However, the complex permeability was not largely affected by the frequency, and the values were decreased with the addition of charcoal powder. Based on the results, it can be summarized that the addition of charcoal powder was very effective to improve the EM wave absorption in the frequency range of 10 MHz$\sim$1 GHz.

도파관 슬롯 커플러용 비대칭 복합 아이리스에 의해 급전되는 중심 종방향 션트-시리즈 결합 슬롯에 관한 연구 (A Study of Center Longitudinal Shunt-Series Coupling Slot Fed by Asymmetric Compound Iris for Waveguide Slot Coupler)

  • 김병문;고지환;조영기
    • 한국전자파학회논문지
    • /
    • 제24권6호
    • /
    • pp.586-594
    • /
    • 2013
  • 본 논문에서는 도파관 슬롯 배열 안테나 설계 시 분기 도파관 내에서 결합 슬롯과 복사 슬롯 간의 원하지 않는 고차 모드 결합을 줄일 수 있는 슬롯 커플러용 결합 요소를 제안하였다. 제안된 소자는 수직 교차하는 두 도파관이 공유하는 도파관 광벽에 위치한 중심 종방향 션트-시리즈 결합 슬롯과 이를 여기시키는 비대칭 복합아이리스로 구성된다. 먼저 HFSS를 사용하여 커플러 구조의 산란 계수를 구하고, 결합 슬롯의 T - 회로망 등가 회로의 파라미터를 추출하였다. 또한, 소자의 구조적인 치수를 변화시키면서 공진 길이 및 정규화 어드미턴스와같은 공진 특성을 분석하였다. 결합 슬롯으로부터 ${\lambda}_g/4$ 떨어진 단락 블록을 갖는 커플러를 설계 제작하여 측정한 실험 결과는 모의실험 결과와 잘 일치하였다.

레이더 신호의 감쇠특성을 고려한 일체식 콘크리트 교량 바닥판의 상태평가 방법 고찰 (A Study on the Integrity Assessment of Bare Concrete Bridge Deck based on the Attenuation of Radar Signals)

  • 이지영;최재진;김홍삼;박고은;최명진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.84-93
    • /
    • 2016
  • 전자기파가 콘크리트 교량 바닥판을 통과할 때 에너지 손실 메카니즘에 의해 신호의 감쇠가 발생하며, 이는 콘크리트의 상대유전율과 전도도, 그리고 지리적 산란 손실의 영향에 따른 것으로 알려져 있다. 본 연구에서는 건전한 콘크리트에 대해서는 레이더파의 감쇠가 상부철근의 깊이와 선형관계에 있다는 점에 착안하여, 일체식 콘크리트 교량 바닥판에서 상태평가 지표로서의 레이더파의 신호감쇠를 실 교량에 적용하여 그 유용성에 대해 검토하였다. 연구결과, 손상된 콘크리트 교량 바닥판에서는 건전한 상태에 비해 상대적으로 큰 감쇠가 일어나며, 레이더 수신파의 총감쇠량에서 반사체의 깊이에 대해 선형적 관계인 부분을 제거하고 난 보정감쇠량은 일체식 콘크리트 교량 바닥판의 상태평가에 유용한 것으로 나타났다. 실제 공용 중인 손상 교량 바닥판에 적용한 결과, 제안된 방법은 교면에서 상부철근까지의 콘크리트 상태를 신뢰성 있게 평가할 수 있으며, 특히, 일체식 바닥판의 주손상요인인 상부철근의 부식환경을 간접적으로 평가할 수 있는 것으로 판단된다.