• Title/Summary/Keyword: EM 센서

Search Result 58, Processing Time 0.022 seconds

Embedded EM Sensor for Tensile Force Estimation of PS tendon of PSC Girder (PS 긴장재 긴장력 계측을 위한 PSC 거더 내부 매립용 EM 센서)

  • Park, Jooyoung;Kim, Junkyeong;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.691-697
    • /
    • 2015
  • In this paper, an embedded EM sensor was researched to estimate prestressing force of PS tendon in PSC girder. Recent methodologies for managing prestressing force loss were staying on verifying a applying prestressing force under construction, namely the loss management can not be controlled after construction. To estimate the tensile force of PS tendon during lifetime of PSC girder, this research proposed a bobbin-type embedded EM sensor that can be embedded in PSC girder is designed and fabricated considering the shape properties of anchorage zone and sheath. To verify the proposed sensor, a small PSC girder test was performed. The embedded EM sensor was connected to a sheath and anchor block, and the concrete was poured. After curing, the change of the permeability of PS tendon under tensile forces of 200, 710, 1070, 1300kN was measured using embedded EM sensor. The permeability of PS tendon had decreased according to the increment of applied tensile force. Also it is confirmed that the change of permeability due to applied tensile force could resolve the applied tensile force values. As a result, proposed embedded EM sensor could be embed into the PSC girder and it could be used to estimate the tensile force variation during lifetime of PSC girder.

Prestressing Loss Management for PSC Girder Tendon Based on EM Sensing (EM센서를 활용한 PSC 텐던 긴장력 손실 관리)

  • Kim, Junkyeong;Park, Jooyoung;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.369-374
    • /
    • 2015
  • In this paper, an EM sensing based prestressing force estimation method is proposed, in which it can estimate tensile force of PS tendon for PSC girder. The PSC girder has more improved performance than the general concrete girder by introducing the prestressing to the concrete. Thus the PSC girder bridge is widely constructed due to its high performance and low cost. However, the prestressing force has not been managed nevertheless it is major factor for the maintenance of the PSC girder bridge. The prestressing force was just measured during construction using jacking device and after that, it can not be managed. For this reason, this paper proposes a tensile force estimation method of PS tendon based on EM sensor. The permeability of ferroelectric material is changed according to the induced stress to the material, in which it can be measured using EM sensor. To measure the permeability of PS tendon, the EM sensor was fabricated and verified by performing the MTS test. The test was performed using 7-wire steel tendon under the 0, 40, 80, 120, 160, 200 KN of tensile force. The permeability of PS tendon was gradually decreased according to the increasement of tensile force. The regression method was used to find the relation between permeability and stress. As a result, the permeability has linear relation with the tensile force of PS tendon and the pre-stressing force can be estimated by the derived estimation equation.

Verification of External Magnetization based EM Technique for Diagnosing Residual Tensile Stress in Aged PSC Structures (노후 PSC 구조물의 잔여 긴장 응력 진단을 위한 외부 자화 EM 기법 검증)

  • Soon-Jeon Park;Sehwan Park;Jaehoon Choi;Kyo-Young Jeon;Junkyeong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2023
  • This study entailed an investigation of a tensile stress measurement method for prestressed concrete (PSC) tendons by utilizing external magnetization. The target of this study are PS structures that have been constructed and in use. An optimal external magnetization based elasto-magnetic (EM) sensor was designed using finite element analysis considering various factors, such as coil arrangement and size, that could influence the PS tendons inside the PSC girder. The residual tensile stress resulting from the external magnetization of the girder was then determined. Further, theoretical verification was performed using the numerical and material data used in the finite element analysis for sensor design. The calculated values of strength of magnetization at the target location were matched with the finite element analysis results. Thus, the designed sensor and the feasibility of magnetizing the tendons inside the PSC I-girder using an EM sensor were validated.

Development of a Seismic Measurement System with a reference for the Reduction of Artificial Noise (인공잡음 제거를 위한 기준점 이용 탄성파 측정시스템 개발)

  • Hwang, Hak-Soo;Lee, Tai-Sup;Sung, Nak-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.4
    • /
    • pp.180-183
    • /
    • 1999
  • A proto-type seismic measurement system with a reference was developed to improve S/N (signal-to-noise ratio) of seismic data, especially in noisy urban areas. Two pairs of correlation measurements (the one for microphone and geophone, and another for electromagnetic (EM) loop and geophone) were carried out near Kimpo Airport and at Kimje. The spectrum analyses were also performed to investigate the correlation of two pairs of time series; one for microphone and geophone, and another for EM loop and geophone. The sound waves measured with the microphone and the geophone are highly correlated. However, differences in the reponses are readily identifiable across 200 Hz; in the vicinity of 100 Hz, the spectral energy for geophone is 20 dB higher than that for microphone, and at near 500 Hz, the spectral energy for microphone is 30 dB higher than that for geophone. Overall, the spectral energy appears concentrated on the frequency window below 600 Hz for geophone. It contrasts with the observation of dominant frequency at the range of above 200 Hz for microphone. The wave forms of EM noise (due to an ACDC inverter) measured with EM loop and geophone are consistently and highly correlated each other. The power spectrum of the EM noise for EM loop shows that the spectral energies at odd harmonic frequencies of 60 Hz are higher than those at even harmonic frequencies of 60 Hz. It is compared to the power spectrum for geophone; the spectral energies at odd harmonics are nearly same as those at even harmonic frequencies.

  • PDF

Characteristics of the EM Probe with Differential Shapes for Partial Discharge Diagnosis (페라이트 형상에 따른 부분방전 진단용 EM Probe의 특성)

  • Yang, Sang-Hyun;Lee, Se-Il;Lee, Yong-Sung;Park, Noh-Joon;Kim, Hee-Dong;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.398-399
    • /
    • 2009
  • 본 논문에서는 XLPE 전력케이블 접속부의 부분방전을 측정하기 위한 Ferrite 형상에 따른 EM Probe를 설계하였다. 부분방전 펄스의 검출대역를 넓이기 위해 투자율이 2400인 페라이트코어를 사용하여 센서를 제작하였고 형상에 따른 특성을 비교하기위하여 실린더형 Ferrite와 말굽형 Ferrite를 적용하였다. 또한 부분방전 검출능력을 확인하기 위해 상용 HFCT센서의 비교 실험을 통하여 위상특성과 주파수 특성을 분석하였다.

  • PDF

EM Algorithm based Air Flow and Power Data classification Analysis (EM 알고리즘기반의 공기 유량 및 전력 데이터 분류 분석)

  • Shim, Jae-Ryong;Noh, Young-Bin;Jung, Hoe-kyung;Kim, Yong-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.551-553
    • /
    • 2016
  • Since air compressor, as an essential equipment used in the factory and plant operations, accounts for around 20% of the total domestic electricity consumption, a real time sensor data monitoring based analysis for electricity consumption reduction is important. In particular, flow rates and pressures of these monitored variables has a direct correlation with the power consumption. This paper proposes a method to identify if the measurement error of the flow rate sensor comes from the sensor measurement limit through bivariate classification analysis of the flow rate and power using the EM (Expectation and Maximization) Algorithm and show how to enable more accurate analysis by the correlation between the flow rate and power on the right-censored data.

  • PDF

Low-Frequency Electromagnetic Leakage Signal Analysis According to Fundamental Operations of Smartphones (스마트폰 기본 동작 모드에 따른 저주파 대역 누설 전자파 신호 특성 분석)

  • Lee, Young-Jun;Park, Heesun;Kwon, YoungHyoun;Lee, Jaeki;Choi, Ji-Eun;Cho, Sangwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.9
    • /
    • pp.1108-1119
    • /
    • 2016
  • This paper presents the spectral analysis and radiation pattern of low-frequency electromagnetic(EM) leakage signals according to the fundamental operations of smartphones. The EM leakage signals generated by the activation of four I/O sensor modules such as a touch-screen, a camera, a microphone and a speaker are captured by the commercial near-field magnetic probe with 1cm spatial resolution. The analysis results show that the leakage of the EM wave occurs strongly around the activated I/O sensor modules, AP(Application Processor) and memory modules. Also, the distinguishable frequency characteristic is shown in each spectrum of EM leakage signals.

24 GHz Microstrip Patch Array Antenna for High Sensitivity EM Sensor (고감도 EM 센서용 24 GHz 마이크로스트립 패치 배열 안테나)

  • Jung, Young-Bae;Jung, Chang-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1116-1120
    • /
    • 2010
  • Low cost patch array antenna for high sensitivity electromagnetic(EM) sensor is presented. The operating frequency band of the antenna is 24.05~24.25 GHz. Array structure is the symmetrical pattern by Chebyshev polynomial and the feed point is located in the middle of the array. Also, the gain of the array antenna can be increased by the side wings which are connected with the ground plane. It is proved through simulation and the measurement results that the operating frequency and the side-lobe level(SLL) are rarely changed when the inclined angle of the side wings is varied.

Comparative Study of Cable Tension Measurement Methods by In-situ Measurements on a Cable-stayed Bridge under Construction (시공 중 사장교 실측을 통한 케이블 장력 추정 기법 비교 연구)

  • Cho, Soo-Jin;Yim, Jin-Suk;Shin, Sung-Woo;Jung, Hyung-Jo;Yun, Chung-Bang;Wang, Ming.L.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.48-51
    • /
    • 2011
  • 사장교에서 케이블은 하중을 지지하는 주요 부재로, 케이블 장력은 사장교의 건전성과 안전도 평가에 있어서 매우 중요한 변수이다. 케이블 장력을 추정하기 위한 대표적인 방법으로는 로드셀을 이용한 직접법과 진동 계측 자료를 이용한 간접법 등이 있으며, 최근에는 자기장-응력 관계를 이용한 EM(Elasto-Magnetic) 센서 측정법이 개발되어 케이블 장력 추정에 적용되었다. 본 논문에서는 세 가지 장력 추정 기법을 실제 시공중인 사장교에 적용하여, 그 성능을 상호 비교하였다. 본 연구는 한국의 KAIST와 미국 Northeastern 대학교의 공동연구로 수행되었다. 대상 교량은 부산 화명동과 김해 초정리를 연결하기 위해 현재 건설중인 화명대교이다. 화명대교의 교량 형식은 2주탑 콘크리트 사장교 (주탑 경간장 270m, 총 사장교 구간장 500m)이며, 사장재로는 MS (Multi-Strand) 형 케이블이 사용되었다. 실험 당시 화명대교는 중앙경간의 폐합 후 선형관리를 위한 장력조정작업을 수행하였으며, 케이블 재긴장시의 정확한 장력관리를 위하여 로드셀을 이용한 Lift-off test방법으로 케이블의 장력을 측정하였다. 이와 동시에 두 개의 케이블을 대상으로 진동 가속도 센서와 EM 센서를 설치하고 장력 계측을 수행하였으며, 재긴장 단계별 장력 변화치를 지속적으로 계측하였다. 계측된 결과를 바탕으로 케이블 장력 추정 기법의 정확성 및 실교량에서의 활용성을 비교하였다.

  • PDF