• Title/Summary/Keyword: EM(Energy Management)

Search Result 42, Processing Time 0.027 seconds

에너지경영시스템(EMS)

  • Kim, Ha-Yeon
    • The Magazine for Energy Service Companies
    • /
    • s.57
    • /
    • pp.24-27
    • /
    • 2009
  • 에너지경영시스템(Energy Management System)이란 최고경영자가 경영방침에 에너지관리 목표를 포함시켜 전사적인 에너지 관리를 추진하는 톱다운(Top-Down) 방식의 에너지관리시스템이다. 에너지 절감을 위해 에너지관리공단에서 도입 및 계획하고 있는 EMS에 대해 알아본다.

  • PDF

Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems (개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.131-139
    • /
    • 2018
  • Many ship researches have been carried out in connection with the fourth revolution, one of which focuses on EMS(energy management system). The EMS is referred to as systems for managing the energy of ships and include various systems. In this paper, we analyze the energy saving field in ship and propose a ship power energy management system including individual load control systems that can save energy in the engine room. EMS includes individual load control systems of PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System). Proposed EMS primarily conserves energy in the individual load systems of the engine room. Secondly, the integrated monitoring and control system is used to control the power generation system and the power load system to save energy.

EMS 메모리 데이터베이스 동기화 기능 개선 개발

  • Kim, Tae-Seop;Kwak, Jong-Kab;Lee, Seok-Chan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1131-1133
    • /
    • 2015
  • EMS(Energy Management System)는 우리나라 전체 전력 계통을 실시간으로 감시, 제어하고 계통 주파수를 자동으로 조정하여 성능 최적화를 유도하는 시스템으로 전력 계통의 두뇌와 같은 역할을 한다. 본 연구에서는 차세대 EMS(Next Generation Energy Management System: NG-EMS)에서 Enable과 Standby 서버 간 데이터베이스 동기화 기능 개선 개발 기술을 소개한다. EMS는 원방제어감시에 사용되는 SCADA(Supervisory Control And Data Acquisition) 데이터를 포함하여 자동발전, 경제급전 등의 전력 계통을 위해 가공된 데이터를 메모리 데이터베이스에 저장한다. 본 연구에서는 EMS의 메모리 데이터베이스에 저장되어 있는 데이터를 시스템 운영자가 선별을 하여 동기화를 수행할 수 있도록 한다. 또한 동기화 되고 있는 현황을 가시적으로 보임으로써 Enable 서버의 장애 발생 시 Standby 서버로의 대체가 유연하고 안정적이며, 신뢰성을 줄 수 있다.

EMS를 중추로 한 급전종합자동화 시스템

  • 김영한;이강완
    • 전기의세계
    • /
    • v.35 no.11
    • /
    • pp.699-709
    • /
    • 1986
  • 전력계통 운용상 점차 고도의 기술이 요구됨에 따라 급전제어소에 설치되는 컴퓨터시스템도 많은 자료를 빠른 시간내에 처리할 수 있도록 대용량의 고속용 계산기가 채용되고 있으며, 이용기술면에서도 온라인 조류계산을 기본으로한 여러가지 진보된 응용기능을 갖추어 가고 있다. 1960년대말 디지탈컴퓨터시스템이 전력계통운용의 자동화를 위하여 특수하게 설계되어 이용된 이래 비약적인 발전을 거듭하면서 최근에는 안전제어(Security Control), 협조계획(Interactive Planning) 그리고 계층제어(Hierarchical Control) 등의 다양한 기능에 의해 전체 전력계통의 안전운용과 효율적운용을 기할 수 있도록 에너지관리시스템(EMS: Energy Management System)이 개발되었으며 세계적으로 많은 전력회사들이 종래에 사용해 오던 AGC/SCADA기능위주의 시스템에서 이 시스템으로 교체해 가고 있다. 우리나라의 한국전력공사에서도 최신기술의 EMS를 도입하기 위한 사업이 1987년 중반기를 준공목표로 1986, 10월말 현재 전체공정의 약 85%가 추진되고 있는데, 여기에서는 이에 관련하여 먼저 EMS의 기술동향과 설계방법에 관해 살펴보고 다음에 한전 EMS의 특징에 대하여 소개하고자 한다.

  • PDF

Application of Total Resource Management System in Korea Energy Management System (한국형 에너지 관리 시스템에 통합자원관리시스템 적용)

  • Lee, Bong-Kil;Yi, Myoung-Hee;Lee, Won-Sang;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.98-99
    • /
    • 2007
  • 전력계통을 감시하고 운영하는 핵심설비인 EMS는 다양한 서버들과 통신장치, 보안장치 및 환경설비 등으로 구성되어 있다. 이들 설비는 네트워크 망에서 데이터를 상호교환하면서 고유의 역할을 수행하며, 특정 설비의 장애는 시스템 전체에 혼란상황을 가져올 수 있다. 따라서 EMS를 구성하는 각종 설비들을 종합하여 실시간으로 감시하는 시스템이 필요하며, 이는 운용자에게 장애발생을 신속히 통보함으로서 시스템의 빠른 복구를 가능하게 한다. 아울러 실시간으로 감시한 시스템 성능데이터를 데이터베이스화함으로서 과거 성능을 분석하고 미래의 사용 추이를 예측할 수 있다. 이처럼 EMS 고유 특징을 고려한 감시시스템을 구축하기 위해서는 다양한 통신 프로토콜을 수용할 수 있는 통합 어댑터 모듈을 개발, 감시시스템에 수용하여야 한다.

  • PDF

Efficient Management for Database Status of EMS (EMS의 데이터베이스 상태에 대한 효율적인 감시 관리 방안)

  • Kwak, Jong-Kab;Kim, tae-Seop;Bahng, Soon-Jong;Lee, Seok-chan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.306-307
    • /
    • 2015
  • Energy Management System(이하 EMS)는 전기를 경제적으로 생산하여 효율적이고 안정적으로 공급하기 위한 종합전력에너지 관리시스템이다. 실시간으로 전달되는 전력, 설비 등의 각종 값을 이용하여 발전량을 계획하고 전력 계통을 감시하고 제어한다. 이러한 취득데이터는 EMS 데이터베이스에 저장되어 갱신되며 실시간으로 처리되고 있다. EMS 데이터베이스는 방대한 양의 취득 및 처리 데이터가 저장된다. 또한, EMS에서 기동되는 다양한 프로세스들이 접근하며 사용자가 정의한 쿼리문에 맞는 데이터를 전달해야 한다. 기동측면에서는 안정적인 삭제 및 생성이 되어야 하며 데이터베이스의 예기치 못한 문제 발생 시 사용자에게 알리고 효율적으로 대처 할 수 있어야 한다. 본 논문에서는 EMS 데이터베이스에 대한 주요 특징을 알고 데이터베이스 상태에 대한 효율적인 감시 방안에 대하여 소개한다.

  • PDF

A Case Study on Operation of Energy Management System Connected with Renewable Energy (신재생에너지 연계형 에너지관리장치의 운영 사례 연구)

  • Cho, Jai Young;Ra, In-Ho
    • Smart Media Journal
    • /
    • v.7 no.2
    • /
    • pp.71-77
    • /
    • 2018
  • This paper proposes the components of the energy management system (EMS) for optimum operation of renewable energy and associated energy storage system (ESS), the functions to be considered in designing, the analysis of operational effects, and finally the reduction of electricity costs. To accomplish the objectives, a lithium-ion battery system and an energy management system have installed in a PV system, and it presents the results analyzed with operation data for a year. To increase the system operation efficiency, we propose the effect that EMS is used to replace the demand power at the peak time with the charge power at the light load time, which suggests the influence of contributing to the charge benefit and load leveling according to the ESS tariff.

A Study on Quantitative methodology to Assess Cyber Security Risks of EMS (스마트그리드 체제에 따른 EMS의 보안 평가를 위한 정량적 방법론에 관한 연구)

  • Woo, Pil Sung;Kim, Balho H.
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.123-131
    • /
    • 2015
  • This paper aims to identify and clarify the cyber security risks and their interaction with the power system in Smart Grid. The EMS and other communication networks interact with the power system on a real time basis, so it is important to understand the interaction between two layers to protect the power system from potential cyber threats. In this study, the optimal power flow(OPF) and Power Flow Tracing are used to assess the interaction between the EMS and the power system. Through OPF and Power Flow Tracing based analysis, the physical and economic impacts from potential cyber threats are assessed, and thereby the quantitative risks are measured in a monetary unit.

A Study on Energy Management System of Sport Facilities using IoT and Bigdata (사물인터넷과 빅데이터를 이용한 스포츠 시설 에너지 관리시스템에 관한 연구)

  • Kwon, Yong-Kwang;Heo, Jun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.59-64
    • /
    • 2020
  • In the Paris Climate Agreement, Korea submitted an ambitious goal of reducing the greenhouse gas emission forecast (BAU) by 37% by 2030. And as one of the countermeasures, a smart grid, an intelligent power grid, was presented. In order to apply the smart grid, EMS(Energy Management System) needs to be installed and operated in various fields, and the supply is delayed due to the lack of awareness of users and the limitations of system ROI. Therefore, recently, various data analysis and control technologies have been proposed to increase the efficiency of the installed EMS. In this study, we present a measurement control algorithm that analyzes and predicts big data collected by IoT using a SARIMA model to check and operate energy consumption of public sports facilities.

[Retracted]Cyber Threat Analysis on Network Communication in Power System and Countermeasures Suggestions ([논문철회]전력계통 네트워크 통신방식 변화에 따른 사이버위협 분석 및 대응방안 제시)

  • Il Hwan Ji;Seungho Jeon;Jung Taek Seo
    • Smart Media Journal
    • /
    • v.12 no.2
    • /
    • pp.91-102
    • /
    • 2023
  • The Energy Management System (EMS) communicates with power plants and substations, monitors the substations and plant operational status of the transmission and substation system for stability, continuity, real-time, and economy of power supply, and controls power plants and substations. Currently, the power exchange EMS communicates with power plants and substations based on the serial communication-based Distributed Network Protocol (DNP) 3.0 protocol. However, problems such as the difficulty of supply and demand of serial communication equipment and the lack of installation space for serial ports and modems are raised due to the continuous increase in new facilities to perform communication, including renewable power generation facilities. Therefore, this paper presents a TCP/IP-based communication method instead of the existing serial communication method of the power exchange EMS, and presents a security risk analysis that may occur due to changes in the communication method and a countermeasure to the security risk.